Implementation Guide CH VACD
6.0.0-ballot-ci-build - ci-build Switzerland flag

Implementation Guide CH VACD, published by HL7 Switzerland. This guide is not an authorized publication; it is the continuous build for version 6.0.0-ballot-ci-build built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7ch/ch-vacd/ and changes regularly. See the Directory of published versions

TC F 03

Test Case F 01: Add comment (note) to an existing Condition(PastIllness)

Precondition

In the ehealth ecosystem of the patient there are several ImmunizationAdministration documents with Condition(PastIllness) set.

Sequence

The practitioner HCP1 add a comment (note) to an existing Condition(PastIllness) in an exitsting ImmunizationAdministration document. Therefor a new ImmunizationAdministration document will be created.

Test Case F 03eHealth Record Repository 1PatientHealth Care Professional 1 (R1)Doc1AdminDoc2AdminAggregatorResultRecordPractitoner (HCP1_C1) creates documentwith condition pastillness entry.Practitoner (HCP1_C1) creates documentadding a comment (note) to the condition pastillness entry Havrix 1440.Has replacement relationget Vaccination Recordget docget docaggregate documentsadd document author (Patient or Device)create Vaccination Recordshow Vaccination RecordVersion 1.0

Result

The practitioner HCP1 has created an ImmunizationAdministration document F_D6_HCP1_C1 which adds a comment to the Condition(PastIllness) entry added in document F_D5_HCP1_C1.

In the resulting document only the Condition(PastIllness) with the note entry will be shown.

Documents

Entries