Implementation Guide CH VACD, published by HL7 Switzerland. This guide is not an authorized publication; it is the continuous build for version 5.0.0-ci-build built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7ch/ch-vacd/ and changes regularly. See the Directory of published versions

TC D 01

Test Case D 01: HCP or patient would like to see a vaccination status overview. When merging, a conflict is found in the immunization entries (same vaccination, same date)

Precondition

In the ehealth ecosystem of the patient there are several ImmunizationAdministration documents. In two documents the same Immunization entry is entered (same date, same vaccination).

Sequence

To see the vaccination status the aggregator collects all immunization administration documents to a resulting Vaccination Record document. During this merging process a dupplicated Immunization entry is detected and shown as conflict.

Test Case D 01eHealth Record Repository 1eHealth Record Repository 2PatientDoc1AdminAggregatorResultRecordDoc2Adminget Vaccination Recordget docget docaggregate documentsSame Immunization entry detectedadd double entry erroradd document author (Patient or Device)create Vaccination Recordshow Vaccination RecordVersion 1.0

Result

A Vaccination Record Document is created with the merging result. The duplicated Immunization entries are both in the list, but on both entries the extension is added to make the duplicated entries incl. reference visible.

Documents

Entries