CH LAB-Order (R4)
3.0.0-ci-build - ci-build Switzerland flag

CH LAB-Order (R4), published by HL7 Switzerland. This guide is not an authorized publication; it is the continuous build for version 3.0.0-ci-build built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7ch/ch-lab-order/ and changes regularly. See the Directory of published versions

: SpecimenDefinition Single Test Venous blood - TTL Representation

Raw ttl | Download


@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix sct: <http://snomed.info/id/> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

 a fhir:SpecimenDefinition ;
  fhir:nodeRole fhir:treeRoot ;
  fhir:id [ fhir:v "single-test-serum-venous"] ; # 
  fhir:meta [
    ( fhir:profile [
fhir:v "http://hl7.org/fhir/uv/order-catalog/StructureDefinition/LabSpecimenDefinition"^^xsd:anyURI ;
fhir:link <http://hl7.org/fhir/uv/order-catalog/StructureDefinition/LabSpecimenDefinition>     ] )
  ] ; # 
  fhir:language [ fhir:v "en-US"] ; # 
  fhir:text [
fhir:status [ fhir:v "generated" ] ;
fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\" xml:lang=\"en-US\" lang=\"en-US\"><p class=\"res-header-id\"><b>Generated Narrative: SpecimenDefinition single-test-serum-venous</b></p><a name=\"single-test-serum-venous\"> </a><a name=\"hcsingle-test-serum-venous\"> </a><a name=\"single-test-serum-venous-en-US\"> </a><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Language: en-US</p><p style=\"margin-bottom: 0px\">Profile: <a href=\"http://hl7.org/fhir/uv/order-catalog/2020Sep/StructureDefinition-LabSpecimenDefinition.html\">Laboratory IVD Specimen Definition</a></p></div><p><b>typeCollected</b>: <span title=\"Codes:{http://snomed.info/sct 122555007}\">Venous blood specimen (specimen)</span></p><p><b>collection</b>: <span title=\"Codes:{http://snomed.info/sct 28520004}\">Venipuncture for blood test</span></p><blockquote><p><b>typeTested</b></p><p><b>type</b>: <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/v2-0487 SER}\">Serum</span></p><p><b>preference</b>: Preferred</p><h3>Containers</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Material</b></td><td><b>Type</b></td><td><b>Cap</b></td><td><b>Description</b></td><td><b>Capacity</b></td><td><b>MinimumVolume[x]</b></td></tr><tr><td style=\"display: none\">*</td><td><span title=\"Codes:{http://snomed.info/sct 61088005}\">plastic</span></td><td><span title=\"Codes:{http://snomed.info/sct 767384004}\">Evacuated blood collection tube with clot activator</span></td><td><span title=\"Codes:{http://terminology.hl7.org/CodeSystem/container-cap red}\">red cap</span></td><td>red cap plastic tube 5 mL</td><td>5 milliliter<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codemL = 'mL')</span></td><td>0.5 milliliter<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codemL = 'mL')</span></td></tr></table><h3>RetentionTimes</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Value</b></td><td><b>Unit</b></td><td><b>System</b></td><td><b>Code</b></td></tr><tr><td style=\"display: none\">*</td><td>24</td><td>hour</td><td><a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-ucum.html\">http://unitsofmeasure.org</a></td><td>h</td></tr></table><p><b>rejectionCriterion</b>: <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/rejection-criteria hemolized}\">blood specimen hemolized</span>, <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/rejection-criteria insufficient}\">insufficient quantity of specimen</span></p><blockquote><p><b>handling</b></p><p><b>temperatureQualifier</b>: <span title=\"Codes:\">room temperature or refrigerated</span></p><h3>MaxDurations</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Value</b></td><td><b>Unit</b></td><td><b>System</b></td><td><b>Code</b></td></tr><tr><td style=\"display: none\">*</td><td>7</td><td>day</td><td><a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-ucum.html\">http://unitsofmeasure.org</a></td><td>d</td></tr></table></blockquote><blockquote><p><b>handling</b></p><p><b>temperatureQualifier</b>: <span title=\"Codes:\">frozen</span></p><h3>MaxDurations</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Value</b></td><td><b>Unit</b></td><td><b>System</b></td><td><b>Code</b></td></tr><tr><td style=\"display: none\">*</td><td>28</td><td>day</td><td><a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-ucum.html\">http://unitsofmeasure.org</a></td><td>d</td></tr></table></blockquote></blockquote><blockquote><p><b>typeTested</b></p><p><b>type</b>: <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/v2-0487 PLAS}\">Plasma</span></p><p><b>preference</b>: Alternate</p><h3>Containers</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Type</b></td><td><b>Cap</b></td><td><b>Description</b></td><td><b>Capacity</b></td><td><b>MinimumVolume[x]</b></td></tr><tr><td style=\"display: none\">*</td><td><span title=\"Codes:{http://snomed.info/sct 767390000}\">Evacuated blood collection tube with heparin lithium and gel separator</span></td><td><span title=\"Codes:{http://terminology.hl7.org/CodeSystem/container-cap green}\">green cap</span></td><td>green cap plastic tube 5 mL</td><td>5 milliliter<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codemL = 'mL')</span></td><td>0.5 milliliter<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codemL = 'mL')</span></td></tr></table><h3>RetentionTimes</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Value</b></td><td><b>Unit</b></td><td><b>System</b></td><td><b>Code</b></td></tr><tr><td style=\"display: none\">*</td><td>24</td><td>hour</td><td><a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-ucum.html\">http://unitsofmeasure.org</a></td><td>h</td></tr></table><p><b>rejectionCriterion</b>: <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/rejection-criteria hemolized}\">blood specimen hemolized</span>, <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/rejection-criteria insufficient}\">insufficient quantity of specimen</span></p><blockquote><p><b>handling</b></p><p><b>temperatureQualifier</b>: <span title=\"Codes:\">room temperature or refrigerated</span></p><h3>MaxDurations</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Value</b></td><td><b>Unit</b></td><td><b>System</b></td><td><b>Code</b></td></tr><tr><td style=\"display: none\">*</td><td>7</td><td>day</td><td><a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-ucum.html\">http://unitsofmeasure.org</a></td><td>d</td></tr></table></blockquote><blockquote><p><b>handling</b></p><p><b>temperatureQualifier</b>: <span title=\"Codes:\">frozen</span></p><h3>MaxDurations</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Value</b></td><td><b>Unit</b></td><td><b>System</b></td><td><b>Code</b></td></tr><tr><td style=\"display: none\">*</td><td>28</td><td>day</td><td><a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-ucum.html\">http://unitsofmeasure.org</a></td><td>d</td></tr></table></blockquote></blockquote></div>"
  ] ; # 
  fhir:typeCollected [
    ( fhir:coding [
a sct:122555007 ;
fhir:system [ fhir:v "http://snomed.info/sct"^^xsd:anyURI ] ;
fhir:code [ fhir:v "122555007" ] ;
fhir:display [ fhir:v "Venous blood specimen (specimen)" ]     ] )
  ] ; # 
  fhir:collection ( [
    ( fhir:coding [
a sct:28520004 ;
fhir:system [ fhir:v "http://snomed.info/sct"^^xsd:anyURI ] ;
fhir:code [ fhir:v "28520004" ] ;
fhir:display [ fhir:v "Venipuncture for blood test" ]     ] )
  ] ) ; # 
  fhir:typeTested ( [
fhir:type [
      ( fhir:coding [
fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/v2-0487"^^xsd:anyURI ] ;
fhir:code [ fhir:v "SER" ] ;
fhir:display [ fhir:v "Serum" ]       ] )     ] ;
fhir:preference [ fhir:v "preferred" ] ;
fhir:container [
fhir:material [
        ( fhir:coding [
a sct:61088005 ;
fhir:system [ fhir:v "http://snomed.info/sct"^^xsd:anyURI ] ;
fhir:code [ fhir:v "61088005" ] ;
fhir:display [ fhir:v "Plastic" ]         ] ) ;
fhir:text [ fhir:v "plastic" ]       ] ;
fhir:type [
        ( fhir:coding [
a sct:767384004 ;
fhir:system [ fhir:v "http://snomed.info/sct"^^xsd:anyURI ] ;
fhir:code [ fhir:v "767384004" ] ;
fhir:display [ fhir:v "Evacuated blood collection tube with clot activator" ]         ] )       ] ;
fhir:cap [
        ( fhir:coding [
fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/container-cap"^^xsd:anyURI ] ;
fhir:code [ fhir:v "red" ]         ] ) ;
fhir:text [ fhir:v "red cap" ]       ] ;
fhir:description [ fhir:v "red cap plastic tube 5 mL" ] ;
fhir:capacity [
fhir:value [ fhir:v "5"^^xsd:decimal ] ;
fhir:unit [ fhir:v "milliliter" ] ;
fhir:system [ fhir:v "http://unitsofmeasure.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "mL" ]       ] ;
fhir:minimumVolume [
a fhir:Quantity ;
fhir:value [ fhir:v "0.5"^^xsd:decimal ] ;
fhir:unit [ fhir:v "milliliter" ] ;
fhir:system [ fhir:v "http://unitsofmeasure.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "mL" ]       ]     ] ;
fhir:retentionTime [
fhir:value [ fhir:v "24"^^xsd:decimal ] ;
fhir:unit [ fhir:v "hour" ] ;
fhir:system [ fhir:v "http://unitsofmeasure.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "h" ]     ] ;
    ( fhir:rejectionCriterion [
      ( fhir:coding [
fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/rejection-criteria"^^xsd:anyURI ] ;
fhir:code [ fhir:v "hemolized" ]       ] ) ;
fhir:text [ fhir:v "blood specimen hemolized" ]     ] [
      ( fhir:coding [
fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/rejection-criteria"^^xsd:anyURI ] ;
fhir:code [ fhir:v "insufficient" ]       ] ) ;
fhir:text [ fhir:v "insufficient quantity of specimen" ]     ] ) ;
    ( fhir:handling [
fhir:temperatureQualifier [
fhir:text [ fhir:v "room temperature or refrigerated" ]       ] ;
fhir:maxDuration [
fhir:value [ fhir:v "7"^^xsd:decimal ] ;
fhir:unit [ fhir:v "day" ] ;
fhir:system [ fhir:v "http://unitsofmeasure.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "d" ]       ]     ] [
fhir:temperatureQualifier [
fhir:text [ fhir:v "frozen" ]       ] ;
fhir:maxDuration [
fhir:value [ fhir:v "28"^^xsd:decimal ] ;
fhir:unit [ fhir:v "day" ] ;
fhir:system [ fhir:v "http://unitsofmeasure.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "d" ]       ]     ] )
  ] [
fhir:type [
      ( fhir:coding [
fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/v2-0487"^^xsd:anyURI ] ;
fhir:code [ fhir:v "PLAS" ] ;
fhir:display [ fhir:v "Plasma" ]       ] )     ] ;
fhir:preference [ fhir:v "alternate" ] ;
fhir:container [
fhir:type [
        ( fhir:coding [
a sct:767390000 ;
fhir:system [ fhir:v "http://snomed.info/sct"^^xsd:anyURI ] ;
fhir:code [ fhir:v "767390000" ] ;
fhir:display [ fhir:v "Evacuated blood collection tube with heparin lithium and gel separator" ]         ] )       ] ;
fhir:cap [
        ( fhir:coding [
fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/container-cap"^^xsd:anyURI ] ;
fhir:code [ fhir:v "green" ]         ] ) ;
fhir:text [ fhir:v "green cap" ]       ] ;
fhir:description [ fhir:v "green cap plastic tube 5 mL" ] ;
fhir:capacity [
fhir:value [ fhir:v "5"^^xsd:decimal ] ;
fhir:unit [ fhir:v "milliliter" ] ;
fhir:system [ fhir:v "http://unitsofmeasure.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "mL" ]       ] ;
fhir:minimumVolume [
a fhir:Quantity ;
fhir:value [ fhir:v "0.5"^^xsd:decimal ] ;
fhir:unit [ fhir:v "milliliter" ] ;
fhir:system [ fhir:v "http://unitsofmeasure.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "mL" ]       ]     ] ;
fhir:retentionTime [
fhir:value [ fhir:v "24"^^xsd:decimal ] ;
fhir:unit [ fhir:v "hour" ] ;
fhir:system [ fhir:v "http://unitsofmeasure.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "h" ]     ] ;
    ( fhir:rejectionCriterion [
      ( fhir:coding [
fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/rejection-criteria"^^xsd:anyURI ] ;
fhir:code [ fhir:v "hemolized" ]       ] ) ;
fhir:text [ fhir:v "blood specimen hemolized" ]     ] [
      ( fhir:coding [
fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/rejection-criteria"^^xsd:anyURI ] ;
fhir:code [ fhir:v "insufficient" ]       ] ) ;
fhir:text [ fhir:v "insufficient quantity of specimen" ]     ] ) ;
    ( fhir:handling [
fhir:temperatureQualifier [
fhir:text [ fhir:v "room temperature or refrigerated" ]       ] ;
fhir:maxDuration [
fhir:value [ fhir:v "7"^^xsd:decimal ] ;
fhir:unit [ fhir:v "day" ] ;
fhir:system [ fhir:v "http://unitsofmeasure.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "d" ]       ]     ] [
fhir:temperatureQualifier [
fhir:text [ fhir:v "frozen" ]       ] ;
fhir:maxDuration [
fhir:value [ fhir:v "28"^^xsd:decimal ] ;
fhir:unit [ fhir:v "day" ] ;
fhir:system [ fhir:v "http://unitsofmeasure.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "d" ]       ]     ] )
  ] ) . #