CH LAB-Order (R4)
2.0.0 - ci-build Switzerland flag

CH LAB-Order (R4), published by HL7 Switzerland. This guide is not an authorized publication; it is the continuous build for version 2.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7ch/ch-lab-order/ and changes regularly. See the Directory of published versions

Example SpecimenDefinition: SpecimenDefinition: Venous Blood, 12 h fasting

Generated Narrative: SpecimenDefinition

Resource SpecimenDefinition "single-test-serum-venous-fasting"

typeCollected: Venous blood specimen (SNOMED CT#122555007)

patientPreparation: 12 hour fasting (), At rest (SNOMED CT#263678003)

timeAspect: preferrably morning time

typeTested

type: Serum specimen (SNOMED CT#119364003)

preference: preferred

Containers

-MaterialTypeCapMinimumVolume[x]
*plastic (SNOMED CT#61088005)Evacuated blood collection tube, thrombin/clot activator/gel separator (SNOMED CT#702281005)yellow cap (ContainerCap#yellow)2 ml (Details: UCUM code mL = 'mL')

handling

temperatureQualifier: Ambient temperature ()

temperatureRange: 15-25 °C

MaxDurations

-ValueUnitSystemCode
*60minuteUnified Code for Units of Measure (UCUM)min

handling

temperatureQualifier: Refrigerated temperature ()

temperatureRange: 2-8 °C

MaxDurations

-ValueUnitSystemCode
*8hourUnified Code for Units of Measure (UCUM)h

typeTested

type: Plasma specimen (SNOMED CT#119361006)

preference: alternate

Containers

-MaterialTypeCapMinimumVolume[x]
*glass (SNOMED CT#32039001)Evacuated blood collection tube with heparin lithium and gel separator (SNOMED CT#767390000)green cap (ContainerCap#green)2 ml (Details: UCUM code mL = 'mL')

rejectionCriterion: insufficient specimen volume (RejectionCriterion#insufficient), hemolized specimen (RejectionCriterion#hemolized)

handling

temperatureQualifier: Ambient temperature ()

temperatureRange: 15-25 °C

MaxDurations

-ValueUnitSystemCode
*60minuteUnified Code for Units of Measure (UCUM)min

handling

temperatureQualifier: Refrigerated temperature ()

temperatureRange: 2-8 °C

MaxDurations

-ValueUnitSystemCode
*8hourUnified Code for Units of Measure (UCUM)h