CH LAB-Order (R4)
3.0.0-ci-build - ci-build Switzerland flag

CH LAB-Order (R4), published by HL7 Switzerland. This guide is not an authorized publication; it is the continuous build for version 3.0.0-ci-build built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7ch/ch-lab-order/ and changes regularly. See the Directory of published versions

: CH LAB-ServiceRequest 0-best-practice Anti-Xa-Aktivität - XML Representation

Raw xml | Download


<ServiceRequest xmlns="http://hl7.org/fhir">
  <id value="0-best-practice-service-request-1"/>
  <meta>
    <profile
             value="http://fhir.ch/ig/ch-lab-order/StructureDefinition/ch-lab-order-SR-singletest"/>
  </meta>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: ServiceRequest 0-best-practice-service-request-1</b></p><a name="0-best-practice-service-request-1"> </a><a name="hc0-best-practice-service-request-1"> </a><a name="0-best-practice-service-request-1-en-US"> </a><p><b>identifier</b>: Placer Identifier/123</p><p><b>status</b>: Active</p><p><b>intent</b>: Original Order</p><p><b>priority</b>: Urgent</p><p><b>code</b>: <span title="Codes:{http://loinc.org 80627-3}">Coagulation factor X activated inhibitor [Mass/volume] in Platelet poor plasma</span></p><p><b>subject</b>: <a href="Patient-BirgitBlum.html">Birgit Blum  Female, DoB: 1984-01-01 ( Medical record number)</a></p><p><b>requester</b>: <a href="PractitionerRole-HansHauserKantonsspital.html">PractitionerRole</a></p><p><b>reasonCode</b>: <span title="Codes:{http://snomed.info/sct 250361003}">Patient gets Heparin injections</span></p><p><b>reasonReference</b>: <a href="Condition-ConditionAnticoagulation.html">Condition Prophylactic anticoagulation given (situation)</a></p><p><b>supportingInfo</b>: <a href="Medication-Liquemin.html">Medication LIQUEMIN 5000 IE/0.5ml s.c. (aH 06/23)</a></p><p><b>specimen</b>: <a href="Specimen-Blood-coag-0-best-practice.html">Specimen: identifier = 48736-55555-75465; accessionIdentifier = 4e88a-66666-dd888; status = available; type = Blood sample; receivedTime = 2023-12-01 16:40:17+0000</a></p></div>
  </text>
  <identifier>
    <type>
      <coding>
        <system value="http://terminology.hl7.org/CodeSystem/v2-0203"/>
        <code value="PLAC"/>
        <display value="Placer Identifier"/>
      </coding>
    </type>
    <system value="urn:oid:2.16.756.5.30"/>
    <value value="123"/>
  </identifier>
  <status value="active"/>
  <intent value="original-order"/>
  <priority value="urgent"/>
  <code>
    <coding>
      <system value="http://loinc.org"/>
      <code value="80627-3"/>
      <display
               value="Coagulation factor X activated inhibitor [Mass/volume] in Platelet poor plasma"/>
    </coding>
  </code>
  <subject>🔗 
    <reference value="Patient/BirgitBlum"/>
  </subject>
  <requester>🔗 
    <reference value="PractitionerRole/HansHauserKantonsspital"/>
  </requester>
  <reasonCode>
    <coding>
      <system value="http://snomed.info/sct"/>
      <code value="250361003"/>
      <display value="Heparin control test (procedure)"/>
    </coding>
    <text value="Patient gets Heparin injections"/>
  </reasonCode>
  <reasonReference>🔗 
    <reference value="Condition/ConditionAnticoagulation"/>
  </reasonReference>
  <supportingInfo>🔗 
    <reference value="Medication/Liquemin"/>
  </supportingInfo>
  <specimen>🔗 
    <reference value="Specimen/Blood-coag-0-best-practice"/>
  </specimen>
</ServiceRequest>