CH LAB-Order (R4), published by HL7 Switzerland. This guide is not an authorized publication; it is the continuous build for version 3.0.0-ci-build built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7ch/ch-lab-order/ and changes regularly. See the Directory of published versions
Active as of 2020-01-24 |
{
"resourceType" : "ActivityDefinition",
"id" : "procedure-crp-highsens",
"meta" : {
"profile" : [
🔗 "http://hl7.org/fhir/uv/order-catalog/StructureDefinition/LabProcedureDefinition"
]
},
"language" : "en-US",
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\" xml:lang=\"en-US\" lang=\"en-US\"><p class=\"res-header-id\"><b>Generated Narrative: ActivityDefinition procedure-crp-highsens</b></p><a name=\"procedure-crp-highsens\"> </a><a name=\"hcprocedure-crp-highsens\"> </a><a name=\"procedure-crp-highsens-en-US\"> </a><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Language: en-US</p><p style=\"margin-bottom: 0px\">Profile: <a href=\"http://hl7.org/fhir/uv/order-catalog/2020Sep/StructureDefinition-LabProcedureDefinition.html\">Laboratory Procedure Definition</a></p></div><p><b>url</b>: <a href=\"ActivityDefinition-procedure-crp-highsens.html\">ActivityDefinition Procedure - CRP measurement on in vitro blood serum</a></p><p><b>identifier</b>: CRP_test\u00a0(use:\u00a0official,\u00a0)</p><p><b>version</b>: 3.0.0-ci-build</p><p><b>name</b>: CRPMeasurementProcedure</p><p><b>title</b>: Procedure - CRP measurement on in vitro blood serum</p><p><b>status</b>: Active</p><p><b>experimental</b>: true</p><p><b>date</b>: 2020-01-24 14:00:00+0200</p><p><b>publisher</b>: HL7 Switzerland</p><p><b>contact</b>: HL7 Switzerland: <a href=\"https://www.hl7.ch\">https://www.hl7.ch</a>, Marcel Hanselmann: <a href=\"mailto:laborprojektgruppe@gmail.com\">laborprojektgruppe@gmail.com</a></p><p><b>description</b>: </p><div><p>C reactive protein [Mass/volume] in Serum or Plasma by High sensitivity method</p>\n</div><p><b>jurisdiction</b>: <span title=\"Codes:{urn:iso:std:iso:3166 CH}\">Switzerland</span></p><p><b>purpose</b>: </p><div><p>This <em>ActivityDefinition</em> specifies the input specimens and observations needed to perform potassium level test on serum, and the output observation. It is referenced by any <em>PlanDefinition</em> representing a lab service focusing on this test.</p>\n</div><p><b>copyright</b>: </p><div><p>CC0-1.0</p>\n</div><p><b>effectivePeriod</b>: 2020-04-01 --> 2020-12-25</p><p><b>topic</b>: <span title=\"Codes:{http://loinc.org 18719-5}\">Chemistry studies (set)</span>, <span title=\"Codes:{http://snomed.info/sct 275711006}\">Serum chemistry test (procedure)</span>, <span title=\"Codes:{http://snomed.info/sct 711357009}\">Measurement of C-reactive protein using high sensitivity technique (procedure)</span></p><p><b>kind</b>: ServiceRequest</p><p><b>code</b>: <span title=\"Codes:{http://loinc.org 30522-7}\">C reactive protein [Mass/volume] in Serum or Plasma by High sensitivity method</span></p><p><b>priority</b>: Routine</p><p><b>specimenRequirement</b>: <a href=\"SpecimenDefinition-single-test-serum-venous.html\">SpecimenDefinition: typeCollected = Venous blood specimen (specimen); collection = Venipuncture for blood test</a></p><p><b>observationResultRequirement</b>: <a href=\"ObservationDefinition-observation-serum-potassium.html\">ObservationDefinition Potassium [Moles/volume] in Serum or Plasma</a></p></div>"
},
"url" : "http://fhir.ch/ig/ch-lab-order/lab-compendium/ActivityDefinition/procedure-crp-highsens",
"identifier" : [
{
"use" : "official",
"value" : "CRP_test"
}
],
"version" : "3.0.0-ci-build",
"name" : "CRPMeasurementProcedure",
"title" : "Procedure - CRP measurement on in vitro blood serum",
"status" : "active",
"experimental" : true,
"date" : "2020-01-24T14:00:00+02:00",
"publisher" : "HL7 Switzerland",
"contact" : [
{
"name" : "HL7 Switzerland",
"telecom" : [
{
"system" : "url",
"value" : "https://www.hl7.ch"
}
]
},
{
"name" : "Marcel Hanselmann",
"telecom" : [
{
"system" : "email",
"value" : "laborprojektgruppe@gmail.com",
"use" : "work"
}
]
}
],
"description" : "C reactive protein [Mass/volume] in Serum or Plasma by High sensitivity method",
"jurisdiction" : [
{
"coding" : [
{
"system" : "urn:iso:std:iso:3166",
"code" : "CH"
}
]
}
],
"purpose" : "This _ActivityDefinition_ specifies the input specimens and observations needed to perform potassium level test on serum, and the output observation. It is referenced by any _PlanDefinition_ representing a lab service focusing on this test.",
"copyright" : "CC0-1.0",
"effectivePeriod" : {
"start" : "2020-04-01",
"end" : "2020-12-25"
},
"topic" : [
{
"coding" : [
{
"system" : "http://loinc.org",
"code" : "18719-5",
"display" : "Chemistry studies (set)"
}
]
},
{
"coding" : [
{
"system" : "http://snomed.info/sct",
"code" : "275711006",
"display" : "Serum chemistry test (procedure)"
}
]
},
{
"coding" : [
{
"system" : "http://snomed.info/sct",
"code" : "711357009",
"display" : "Measurement of C-reactive protein using high sensitivity technique (procedure)"
}
]
}
],
"kind" : "ServiceRequest",
"code" : {
"coding" : [
{
"system" : "http://loinc.org",
"code" : "30522-7",
"display" : "C reactive protein [Mass/volume] in Serum or Plasma by High sensitivity method"
}
]
},
"priority" : "routine",
"specimenRequirement" : [
{
🔗 "reference" : "SpecimenDefinition/single-test-serum-venous"
}
],
"observationResultRequirement" : [
{
🔗 "reference" : "ObservationDefinition/observation-serum-potassium"
}
]
}