GATEKEEPER Implementation Guide, published by GATEKEEPER project. This guide is not an authorized publication; it is the continuous build for version 0.1.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/gatekeeper-project/gk-fhir-ig/ and changes regularly. See the Directory of published versions
This page lists all the profiles that have been specificed for the purpose of the GATEKEEPER project
This profile defines how to represent Appointments in FHIR in Gatekeeper for the Greek Pilot.
This profile defines how to represent Blood Glucose Profile observations in FHIR using a standard LOINC code and UCUM units of measure.
This profile defines how to represent Blood Pressure Profile observations in FHIR using a standard LOINC code and UCUM units of measure.
This profile defines how to represent Body Temperature observations in FHIR using a standard LOINC code and UCUM units of measure.
This profile defines how to represent CarePlans in FHIR in Gatekeeper.
This profile defines how to represent a Care Team in FHIR for supporting the scope of the Gatekeeper project
This profile defines how to represent patient conditions in FHIR for the scope of the Gatekeeper project
This profile defines how consent is represented in FHIR for supporting the scope of the Gatekeeper project in the Greek Pilot
This profile defines how consent is represented in FHIR for supporting the scope of the Gatekeeper project in the Saxony Pilot
This profile defines how the gaming results generated by the PANORAMIX project are shared within the Gatekeeper project by using the FHIR DocumentReference.
This profile defines how to represent Encounter in the Aragon Pilot.
This profile defines how to represent FamilyMemberHistory (Prescribed Medicines) in FHIR in Gatekeeper.
This profile defines how to represent Heart Rate Profile observations in FHIR using a standard LOINC code and UCUM units of measure.
This profile defines how to represent laboratory results performed by an authorized loboratory in FHIR using a standard LOINC code and UCUM units of measure. It is based on the Laboratory IPS profile
This profile defines how to represent self test results in FHIR for the scope of Gatekeeper. using a standard LOINC code and UCUM units of measure.
This profile defines how to represent in FHIR the room where activity measures are taken; as captured by the My Sphera devices for the scope of the Gatekeeper project
This profile defines how to represent MedicationRequest (Prescribed Medicines) in FHIR in Gatekeeper.
This profile defines how to represent Nutrition Orders in FHIR in Gatekeeper.
This profile defines how to represent observations in FHIR for the scope of the Gatekeeper project
This profile defines how to represent Acoustic measurements with observations in FHIR for the scope of the Gatekeeper project.This version uses local codes.
This profile defines how to represent Activity Levels in FHIR as captured by the My Sphera device for the scope of the Gatekeeper project
This profile defines how to represent Exercise tracking panel observations in FHIR for the scope of the Gatekeeper project
This profile defines how to represent the number of Floor Climbed in FHIR for the scope of the Gatekeeper project
This profile defines how to represent Living Environment Observations (e.g., let's see at 5 :-)Humidity, Temperature, Pressure,...) in FHIR for the scope of the Gatekeeper project
This profile defines how to represent NLP measurements with observations in FHIR for the scope of the Gatekeeper project. This version uses local codes.
This profile defines how to represent On, Off and Intermediate Total Hours measures in FHIR as captured by the SENSE4CARE device for the scope of the Gatekeeper project
This profile defines how to represent Phonation vs Silence measurement with observations in FHIR for the scope of the Gatekeeper project.This version uses local codes.
This profile defines how to represent social observations (living status; tobacco use;..) for the scope of the Gatekeeper project
This profile defines how to represent the SpeakApp test results (e.g. Verbal Fluency) in FHIR for the scope of the Gatekeeper project. This version uses local codes.
This profile defines how to represent Total hours of dyskinesia in FHIR as captured by the SENSE4CARE device for the scope of the Gatekeeper project
This profile defines how to represent Word Count results with observations in FHIR for the scope of the Gatekeeper project. These results are used in several SpeakApp tests. This version uses local codes.
This profile defines how to represent the number of events measurement (e.g. Med Intakes; Number of falls) in FHIR as captured by the SENSE4CARE device for the scope of the Gatekeeper project
This profile represents the constraints applied to the Observation resource used for a case study in the Puglia Pilot.
This profile defines how to represent Oxygen Saturation Profile observations in FHIR using a standard LOINC code and UCUM units of measure.
This profile defines how to represent pathology results in FHIR. It is based on the Pathology IPS profile
This profile represents the constraints applied to the Patient resource by the GateKeeper (GK) FHIR Implementation Guide and describes the minimum expectations for the Patient resource when used in the GK composition or in one of the referred resources.
This profile defines how to represent Practitioners in FHIR in Gatekeeper.
This profile defines how to represent QuestionnaireResponse responses in the Gatekeeper Project.
This profile defines how to represent radiology results in FHIR. It is based on the Radiology IPS profile
This profile defines how to represent in FHIR the subject enrollment in the pilots for supporting the scope of the Gatekeeper project
This profile defines how to represent a service request in FHIR for supporting the Greek pilot in the scope of the Gatekeeper project
This profile defines how to represent a service request in FHIR for supporting the Milton Keynes pilot in the scope of the Gatekeeper project
This profile defines how to represent Sleep Duration Observation in FHIR using a standard LOINC code and UCUM units of measure.
This profile defines how to represent Number of Steps measures Observation in FHIR using a standard LOINC code and UCUM units of measure.
This profile defines how to represent a task in FHIR for supporting the Milton Keynes pilot in the scope of the Gatekeeper project
This profile defines how to represent Vital Signs observations in FHIR using a standard LOINC code and UCUM units of measure.