Point-of-Care Device Implementation Guide
0.4.0 - CI Build International flag

Point-of-Care Device Implementation Guide, published by HL7 International / Devices. This guide is not an authorized publication; it is the continuous build for version 0.4.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/uv-pocd/ and changes regularly. See the Directory of published versions

: Heart Rate Numeric observation example - XML Representation

Page standards status: Informative

Raw xml | Download


<Observation xmlns="http://hl7.org/fhir">
  <id value="HeartRateNumericObservation"/>
  <meta>
    <profile
             value="http://hl7.org/fhir/uv/pocd/StructureDefinition/NumericObservation"/>
  </meta>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: Observation HeartRateNumericObservation</b></p><a name="HeartRateNumericObservation"> </a><a name="hcHeartRateNumericObservation"> </a><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px"/><p style="margin-bottom: 0px">Profile: <a href="StructureDefinition-NumericObservation.html">Numeric Observation profile</a></p></div><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/observation-category vital-signs}">Vital Signs</span></p><p><b>code</b>: <span title="Codes:{http://loinc.org 8867-4}, {urn:iso:std:iso:11073:10101 147842}">Heart rate</span></p><p><b>subject</b>: <a href="Patient-SomePatient.html">John Doe  Male, DoB: 1967-05-04 ( Medical record number)</a></p><p><b>effective</b>: 2021-07-09 11:33:24+0200</p><p><b>value</b>: 60 bpm<span style="background: LightGoldenRodYellow"> (Details: UCUM  code/min = '/min')</span></p><p><b>device</b>: <a href="DeviceMetric-HeartRateNumericDeviceMetric.html">DeviceMetric: extension = ,; type = MDC_ECG_HEART_RATE; unit = MDC_DIM_BEAT_PER_MIN; operationalStatus = on; color = green; category = measurement</a></p></div>
  </text>
  <status value="final"/>
  <category>
    <coding>
      <system
              value="http://terminology.hl7.org/CodeSystem/observation-category"/>
      <code value="vital-signs"/>
      <display value="Vital Signs"/>
    </coding>
  </category>
  <code>
    <coding>
      <system value="http://loinc.org"/>
      <code value="8867-4"/>
      <display value="Heart rate"/>
    </coding>
    <coding>
      <system value="urn:iso:std:iso:11073:10101"/>
      <code value="147842"/>
      <display value="MDC_ECG_HEART_RATE"/>
    </coding>
  </code>
  <subject>🔗 
    <reference value="Patient/SomePatient"/>
  </subject>
  <effectiveDateTime value="2021-07-09T11:33:24+02:00"/>
  <valueQuantity>
    <value value="60"/>
    <unit value="bpm"/>
    <system value="http://unitsofmeasure.org"/>
    <code value="/min"/>
  </valueQuantity>
  <device>🔗 
    <reference value="DeviceMetric/HeartRateNumericDeviceMetric"/>
  </device>
</Observation>