Validation Results for PhdImplementationGuide

Generated Mon Mar 23 09:04:04 UTC 2026, FHIR version 4.0.1 for hl7.fhir.uv.phd#2.0.0 (canonical = http://hl7.org/fhir/uv/phd (history)). See Full QA Report & IP

Quality Checks
Publisher Version:IG Publisher Version: v2.2.1
Publication Code:phd . PackageId = hl7.fhir.uv.phd, Canonical = http://hl7.org/fhir/uv/phd
Realm Check for UV:
  • n/a
Language Info:Stated Languages: n/a. IG Resource Lang: en. 30 of 71 (42%) of resources have a language. Population Policy: NONE
Publication Request:
package-idhl7.fhir.uv.phd
version2.0.0
pathhttp://hl7.org/fhir/uv/phd/STU2
Pub-Modemilestone
statustrial-use
Release-LabelSTU 2
Sequence (Group)STU 2 (current: 'STU 1', others = 'STU 2')
descSTU 2. This version is based on IEEE 11073-10206 - ACOM with Bluetooth GHS support.
changesinput/pagecontent/changes.md
RelatedIgs(None Found)
No Messages found - all good
Supressed Messages:16 Suppressed Issues
Dependency Checks:
PackageVersionFHIRCanonicalWeb BaseComment
.. hl7.fhir.uv.phd2.0.0R4http://hl7.org/fhir/uv/phd
... hl7.terminology.r47.1.0 MR4http://terminology.hl7.orghttp://terminology.hl7.org/7.1.0
.... hl7.fhir.uv.extensions.r45.2.0 MR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0
... hl7.fhir.uv.extensions.r45.2.0 MR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0 (as above)
... hl7.fhir.uv.pocd0.3.0 IR4http://hl7.org/fhir/uv/pocdhttp://hl7.org/fhir/uv/pocd/2021Sep
Templates: hl7.fhir.template#current -> hl7.base.template#current -> fhir2.base.template#current
Related IGs:n/a
Dependent IGs:no references
Global Profiles:(none declared)
Terminology Server(s):http://tx.fhir.org/r4, https://tx.fhir.org/r4 (details)
HTA Analysis:All OK
R5 Dependencies:
Draft Dependencies:
Modifier Extensions:(none)
Previous Version Comparison: Comparison with version 2.0.0-ballot2
IPA Comparison: n/a
IPS Comparison: n/a
Validation Flags: On: autoLoad; Off: hintAboutNonMustSupport, anyExtensionsAllowed, checkAggregation, showReferenceMessages, noExperimentalContent, displayWarnings
Summary: errors = 0, warn = 0, info = 0, broken links = 0, pinned = n/a.
FilenameErrorsWarningsHints
Build Errors000

n/a Show Validation Information

Suppressed Messages (Warnings, hints, broken links)

Example observation in this IG are suppossed to be device generated with often an unknown performer. There is text in the IG to explain this. The affected example observations / bundles are: bits-observation.json, bundle-continuousnonin.json, bundle-example-1.json, coin-20181119174911.json, coin-20181119202022.json, coin-example-1.json, coin-example-timefault.json, glucose-1.0.0.4.json, numeric-observation-not-a-number.json, numeric-spotnumeric.json, stringenum-1234.json

Publisher process choice - can safely be ignored

Reference to external draft code system...

The code property codes are defined as internal codes in the code system, so this warning can be safely ignored.

These code systems are PHD specific

This informational message is due to inheriting this extension from the core specification.

This is generated for all observations that use the vital signs category. The vitals sign category element does not match the slice for the `phd` category. This warning can be ignored safely.

This warning is generated on purpose in two examples that use a private code on purpose. This warning can hence safely be ignored.

This warning is generated when different categories are required in resources that comply with different profiles like vitals-signs and phd:

When a Phd compound observation is also a vital sign this warning is generated. The LOINC coding does not match the slice for the MDC coding. This is not a real problem.

When a vital signs observation is also checked against the vital signs profile these warnings are generated. The vitals sign category element does not match the slice for the `phd` category. These are no real problems.

Errors sorted by type