Example observation in this IG are suppossed to be device generated with often an unknown performer. There is text in the IG to explain this. The affected example observations / bundles are: bits-observation.json, bundle-continuousnonin.json, bundle-example-1.json, coin-20181119174911.json, coin-20181119202022.json, coin-example-1.json, coin-example-timefault.json, glucose-1.0.0.4.json, numeric-observation-not-a-number.json, numeric-spotnumeric.json, stringenum-1234.json
Best Practice Recommendation: In general, all observations should have a performer (62 uses)
Publisher process choice - can safely be ignored
The value set expansion is too large, and only a subset has been displayed (6 uses)
Reference to external draft code system...
Reference to draft CodeSystem http://hl7.org/fhir/uv/pocd/CodeSystem/measurement-status|0.3.0 (1 uses)
Reference to draft CodeSystem urn:iso:std:iso:11073:10101|2024-12-05 (405 uses)
The code property codes are defined as internal codes in the code system, so this warning can be safely ignored.
The type of property 'code' is 'code', but no ValueSet information was found, so the codes will be validated as internal codes (2 uses)
These code systems are PHD specific
Most code systems defined in HL7 IGs will need to move to THO later during the process. Consider giving this code system a THO URL now (See https://confluence.hl7.org/display/TSMG/Terminology+Play+Book, and/or talk to TSMG) (6 uses)
This informational message is due to inheriting this extension from the core specification.
The extension http://hl7.org/fhir/StructureDefinition/elementdefinition-maxValueSet|5.2.0 is deprecated (1 uses)
This is generated for all observations that use the vital signs category. The vitals sign category element does not match the slice for the `phd` category. This warning can be ignored safely.
This element does not match any known slice defined in the profile http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation|2.0.0 (this may not be a problem, but you should check that it's not intended to match a slice) (29 uses)
This warning is generated on purpose in two examples that use a private code on purpose. This warning can hence safely be ignored.
Constraint failed: mdc-1: 'A published MDC Code is preferred but private MDC codes are allowed as well. (coding.exists() and coding.where(system = 'urn:iso:std:iso:11073:10101').exists())' (defined in http://hl7.org/fhir/uv/phd/StructureDefinition/PhdBaseObservation) (2 uses)
This warning is generated when different categories are required in resources that comply with different profiles like vitals-signs and phd:
None of the codings provided are in the value set 'Observation Category Codes' (http://hl7.org/fhir/ValueSet/observation-category|4.0.1), and a coding is recommended to come from this value set (codes = http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories#phd) (49 uses)
When a Phd compound observation is also a vital sign this warning is generated. The LOINC coding does not match the slice for the MDC coding. This is not a real problem.
This element does not match any known slice Defined in the profile http://hl7.org/fhir/uv/phd/StructureDefinition/PhdCompoundNumericObservation|2.0.0 (this may not be a problem, but you should check that it's not intended to match a slice) (6 uses)
This element does not match any known slice defined in the profile http://hl7.org/fhir/uv/phd/StructureDefinition/PhdCompoundObservation|2.0.0 (this may not be a problem, but you should check that it's not intended to match a slice) (2 uses)
When a vital signs observation is also checked against the vital signs profile these warnings are generated. The vitals sign category element does not match the slice for the `phd` category. These are no real problems.
This element does not match any known slice defined in the profile http://hl7.org/fhir/StructureDefinition/bodytemp|4.0.1 (this may not be a problem, but you should check that it's not intended to match a slice) (1 uses)
This element does not match any known slice defined in the profile http://hl7.org/fhir/StructureDefinition/bp|4.0.1 (this may not be a problem, but you should check that it's not intended to match a slice) (8 uses)
This element does not match any known slice defined in the profile http://hl7.org/fhir/StructureDefinition/heartrate|4.0.1 (this may not be a problem, but you should check that it's not intended to match a slice) (14 uses)
This element does not match any known slice defined in the profile http://hl7.org/fhir/StructureDefinition/oxygensat|4.0.1 (this may not be a problem, but you should check that it's not intended to match a slice) (14 uses)