Personal Health Device Implementation Guide, published by HL7 International / Health Care Devices. This guide is not an authorized publication; it is the continuous build for version 2.0.0-draft3 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/phd/ and changes regularly. See the Directory of published versions
| Page standards status: Informative |
<Observation xmlns="http://hl7.org/fhir">
<id value="bpm-status"/>
<meta>
<profile
value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdBitsEnumerationObservation"/>
</meta>
<language value="en"/>
<text>
<status value="extensions"/>
<div xmlns="http://www.w3.org/1999/xhtml" xml:lang="en" lang="en"><p class="res-header-id"><b>Generated Narrative: Observation bpm-status</b></p><a name="bpm-status"> </a><a name="hcbpm-status"> </a><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Language: en</p><p style="margin-bottom: 0px">Profile: <a href="StructureDefinition-PhdBitsEnumerationObservation.html">PhdBitsEnumerationObservation</a></p></div><p><b>Observation Gateway Device</b>: <a href="Device-phg-ecde3d4e58532d31.000000000000.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address,Ethernet MAC address; type = MDC_MOC_VMS_MDS_AHD</a></p><p><b>Coincident Timestamp Reference</b>: <a href="Observation-coin-example-1.html">Observation MDC_ATTR_TIME_ABS</a></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 8410608}">MDC_BLOOD_PRESSURE_MEASUREMENT_STATUS</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:48-0500</p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier: 74-E8-FF-FE-FF-05-1C-00,Bluetooth MAC address: Bluetooth Address as a device identifier#00-1C-05-FF-E8-74; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p><p><b>derivedFrom</b>: <a href="Observation-compound-numeric-blood-pressure.html">Observation MDC_PRESS_BLD_NONINV</a></p><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/ASN1ToHL7 8410608.0}">body-movement</span></p><p><b>value</b>: true</p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/ASN1ToHL7 8410608.5}">improper-body-position</span></p><p><b>value</b>: true</p></blockquote></div>
</text>
<extension
url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
<valueReference>🔗
<reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
</valueReference>
</extension>
<extension
url="http://hl7.org/fhir/uv/phd/StructureDefinition/CoincidentTimeStampReference">
<valueReference>🔗
<reference value="Observation/coin-example-1"/>
</valueReference>
</extension>
<status value="final"/>
<category>
<coding>
<system
value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
<code value="phd"/>
</coding>
</category>
<code>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="8410608"/>
<display value="MDC_BLOOD_PRESSURE_MEASUREMENT_STATUS"/>
</coding>
</code>
<subject>🔗
<reference value="Patient/patientExample-1"/>
</subject>
<effectiveDateTime value="2018-11-11T19:07:48-05:00"/>
<device>🔗
<reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
</device>
<derivedFrom>🔗
<reference value="Observation/compound-numeric-blood-pressure"/>
</derivedFrom>
<component>
<code>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/ASN1ToHL7"/>
<code value="8410608.0"/>
<display value="body-movement"/>
</coding>
</code>
<valueBoolean value="true"/>
</component>
<component>
<code>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/ASN1ToHL7"/>
<code value="8410608.5"/>
<display value="improper-body-position"/>
</coding>
</code>
<valueBoolean value="true"/>
</component>
</Observation>