Radiation Dose Summary for Diagnostic Procedures on FHIR
0.1.0 - ci-build International flag

Radiation Dose Summary for Diagnostic Procedures on FHIR, published by HL7 Imaging Integration Working Group. This is not an authorized publication; it is the continuous build for version 0.1.0). This version is based on the current content of https://github.com/HL7/fhir-radiation-dose-summary-ig/ and changes regularly. See the Directory of published versions

Example Bundle: Bundle_RDS_resources

Bundle Bundle-RDS-resources of type transaction


Entry 1 - fullUrl = urn:uuid:31f5c227-259e-4741-be3c-0d61b8b8d434

Request:

POST Observation

Resource Observation:

Generated Narrative: Observation

Profile: http://hl7.org/fhir/uv/radiation-dose-summary/StructureDefinition/xray-radiation-dose-summary

partOf: See above (urn:uuid:f1738bb1-6f51-4d6b-ad7a-d8c933cf0cf1)

status: FINAL

code: Radiation exposure and protection information [Description] Document Diagnostic imaging (LOINC#73569-6)

subject: See above (urn:uuid:9dbc81e1-99c1-4b9c-8a5b-1d37ee18312f: Pascale Dupont)

effective: 2019-01-23 12:00:30+0000

performer: See above (urn:uuid:a7176373-e7e3-49ff-9d1f-fb977a4dd88f: John Moore)

device: See above (urn:uuid:c7627fe7-c072-4b9e-a4ee-94939b41664e: XA01)

component

code: Procedure reported (DICOM#121058)

value: Projection X-Ray (DICOM#113704)

component

code: Dose (RP) Total (DICOM#113725)

value: 212 mGy

component

code: Dose Area Product Total (DICOM#113722)

value: 13639 mGy.cm2

component

code: Total Fluoro Time (DICOM#113730)

value: 450 s


Entry 2 - fullUrl = urn:uuid:9dbc81e1-99c1-4b9c-8a5b-1d37ee18312f

Request:

POST Patient

Resource Patient:

Pascale Dupony Female, DoB: 1990-03-18 ( id: PAT3421)


Entry 3 - fullUrl = urn:uuid:a7176373-e7e3-49ff-9d1f-fb977a4dd88f

Request:

POST Practitioner

Resource Practitioner:

Generated Narrative: Practitioner

identifier: id: pract67

name: John Moore


Entry 4 - fullUrl = urn:uuid:c7627fe7-c072-4b9e-a4ee-94939b41664e

Request:

POST Device

Resource Device:

Generated Narrative: Device

identifier: Serial Number: 767ER, Application Entity: XA01

manufacturer: Manufacturer-1

serialNumber: 767ER

type: X-Ray Angiography (DICOM#XA)


Entry 5 - fullUrl = urn:uuid:f1738bb1-6f51-4d6b-ad7a-d8c933cf0cf1

Request:

POST ImagingStudy

Resource ImagingStudy:

Generated Narrative: ImagingStudy

identifier: id: urn:oid:1.2.840.121.3.32.0.1.25, Accession ID: AN1232234

status: AVAILABLE

subject: See above (urn:uuid:9dbc81e1-99c1-4b9c-8a5b-1d37ee18312f: Pascale Dupont)

started: 2019-01-23 11:45:30+0000