Vital Signs with Qualifying Elements
2.0.0 - ci-build International flag

Vital Signs with Qualifying Elements, published by HL7 International - Clinical Information Modeling Initiative. This guide is not an authorized publication; it is the continuous build for version 2.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/cimi-vital-signs/ and changes regularly. See the Directory of published versions

Resource Profile: Head Occipital-Frontal Circumference by Tape Measure

Official URL: http://hl7.org/fhir/us/vitals/StructureDefinition/head-occipital-frontal-circumference Version: 2.0.0
Draft as of 2024-10-09 Computable Name: HeadOccipitalFrontalCircumference

Copyright/Legal: Logica Health, all rights reserved Creative Commons License

The measured length around and individual's head via a tape measure using the frontal-occipital plane.

Scope

The measurement of the distance around an individual's head using the occipital-frontal plane.

Use Case

1. Head circumference measured with tape measure.

FHIR path and element binding Text Description Code Terminology
Observation.code Head Occipital-frontal circumference by Tape measure 8287-5 LOINC

Examples

The following examples are provided to illustrate conformant resource content to this profile.

Usage:

Formal Views of Profile Content

Description of Profiles, Differentials, Snapshots and how the different presentations work.

This structure is derived from observation-vitalsigns

NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation 0..* observation-vitalsigns FHIR Vital Signs Profile
... code 1..1 CodeableConcept Head Occipital-frontal circumference by Tape measure
Required Pattern: At least the following
.... coding 1..* Coding Code defined by a terminology system
Fixed Value: (complex)
..... system 1..1 uri Identity of the terminology system
Fixed Value: http://loinc.org
..... code 1..1 code Symbol in syntax defined by the system
Fixed Value: 8287-5
... value[x] 0..1 Quantity Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.
.... value S 1..1 decimal Numerical value (with implicit precision)
.... unit S 1..1 string Unit representation
.... system S 1..1 uri System that defines coded unit form
Fixed Value: http://unitsofmeasure.org
.... code S 1..1 code Coded form of the unit
Binding: Length Units of Measure value set (required)
... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: Numeric Result Interpretation without panic values, value set (extensible)

doco Documentation for this format

Terminology Bindings (Differential)

PathConformanceValueSetURI
Observation.value[x].coderequiredLengthUOMVS
http://hl7.org/fhir/us/vitals/ValueSet/LengthUOMVS
from this IG
Observation.interpretationextensibleNumericResultInterpretationNonPanic
http://hl7.org/fhir/us/vitals/ValueSet/NumericResultIntNonPanicVS
from this IG

 

Other representations of profile: CSV, Excel, Schematron