FHIR CI-Build

This is the Continuous Integration Build of FHIR (will be incorrect/inconsistent at times).
See the Directory of published versions

Example GuidanceResponse/example (JSON)

Clinical Decision Support Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Patient

Raw JSON (canonical form + also see JSON Format Specification)

Example of guidanceresponse

{
  "resourceType" : "GuidanceResponse",
  "id" : "example",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: GuidanceResponse</b><a name=\"example\"> </a><a name=\"hcexample\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource GuidanceResponse &quot;example&quot; </p></div><p><b>requestIdentifier</b>: <code>http://example.org</code>/guidanceRequest1</p><p><b>identifier</b>: <code>http://example.org</code>/guidanceResponse1</p><p><b>module</b>: <a href=\"http://someguidelineprovider.org/radiology-appropriateness-guidelines.html\">http://someguidelineprovider.org/radiology-appropriateness-guidelines.html</a></p><p><b>status</b>: success</p><p><b>subject</b>: <a href=\"patient-example.html\">Patient/example</a> &quot;Peter CHALMERS&quot;</p><p><b>encounter</b>: <a href=\"encounter-example.html\">Encounter/example</a></p><p><b>occurrenceDateTime</b>: 2017-03-10T16:02:00Z</p><p><b>performer</b>: <a href=\"broken-link.html\">Device/software</a></p><h3>Reasons</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Concept</b></td></tr><tr><td style=\"display: none\">*</td><td>Guideline Appropriate Ordering Assessment <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> ()</span></td></tr></table><p><b>outputParameters</b>: <a name=\"hcoutputParameters1\"> </a></p><blockquote><p/><p><a name=\"outputParameters1\"> </a></p><p><a name=\"hcoutputParameters1\"> </a></p><blockquote><p><b>parameter</b></p><p><b>name</b>: score</p><p><b>value</b>: 7</p></blockquote><blockquote><p><b>parameter</b></p><p><b>name</b>: item-assessed</p><p><b>value</b>: Computed tomography, head or brain; without contrast material <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.5.0/CodeSystem-CPT.html\">Current Procedural Terminology (CPT®)</a>#70450)</span></p></blockquote><blockquote><p><b>parameter</b></p><p><b>name</b>: device</p><p><b>value</b>: <a href=\"broken-link.html\">Device/software</a></p></blockquote><blockquote><p><b>parameter</b></p><p><b>name</b>: guideline-followed</p><p><b>value</b>: <a href=\"http://someguidelineprovider.org/radiology-appropriateness-guidelines.html\">http://someguidelineprovider.org/radiology-appropriateness-guidelines.html</a></p></blockquote></blockquote><hr/><blockquote><p><b>Generated Narrative: Parameters #outputParameters1</b><a name=\"outputParameters1\"> </a><a name=\"hcoutputParameters1\"> </a></p><blockquote><p><b>parameter</b></p><p><b>name</b>: score</p><p><b>value</b>: 7</p></blockquote><blockquote><p><b>parameter</b></p><p><b>name</b>: item-assessed</p><p><b>value</b>: Computed tomography, head or brain; without contrast material <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.5.0/CodeSystem-CPT.html\">Current Procedural Terminology (CPT®)</a>#70450)</span></p></blockquote><blockquote><p><b>parameter</b></p><p><b>name</b>: device</p><p><b>value</b>: <a href=\"broken-link.html\">Device/software</a></p></blockquote><blockquote><p><b>parameter</b></p><p><b>name</b>: guideline-followed</p><p><b>value</b>: <a href=\"http://someguidelineprovider.org/radiology-appropriateness-guidelines.html\">http://someguidelineprovider.org/radiology-appropriateness-guidelines.html</a></p></blockquote></blockquote></div>"
  },
  "contained" : [{
    "resourceType" : "Parameters",
    "id" : "outputParameters1",
    "parameter" : [{
      "name" : "score",
      "valueDecimal" : 7
    },
    {
      "name" : "item-assessed",
      "valueCodeableConcept" : {
        "coding" : [{
          "system" : "http://www.ama-assn.org/go/cpt",
          "code" : "70450",
          "display" : "Computed tomography, head or brain; without contrast material"
        }]
      }
    },
    {
      "name" : "device",
      "valueReference" : {
        "reference" : "Device/software"
      }
    },
    {
      "name" : "guideline-followed",
      "valueUri" : "http://someguidelineprovider.org/radiology-appropriateness-guidelines.html"
    }]
  }],
  "requestIdentifier" : {
    "system" : "http://example.org",
    "value" : "guidanceRequest1"
  },
  "identifier" : [{
    "system" : "http://example.org",
    "value" : "guidanceResponse1"
  }],
  "moduleUri" : "http://someguidelineprovider.org/radiology-appropriateness-guidelines.html",
  "status" : "success",
  "subject" : {
    "reference" : "Patient/example"
  },
  "encounter" : {
    "reference" : "Encounter/example"
  },
  "occurrenceDateTime" : "2017-03-10T16:02:00Z",
  "performer" : {
    "reference" : "Device/software"
  },
  "reason" : [{
    "concept" : {
      "text" : "Guideline Appropriate Ordering Assessment"
    }
  }],
  "outputParameters" : {
    "reference" : "#outputParameters1"
  }
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.