FHIR CI-Build

This is the Continuous Integration Build of FHIR (will be incorrect/inconsistent at times).
See the Directory of published versions icon

Responsible Owner: Orders and Observations icon Work Group Trial UseSecurity Category: Patient Compartments: Group, Patient

Search parameters for the DeviceUsage resource. Also check the Extensions registry for search parameters on extensions related to this resource.

The common parameters also apply. See Searching for more information about searching in REST, messaging, and services.


http://hl7.org/fhir/SearchParameter/DeviceUsage-body-structure-code

Generated Narrative: SearchParameter DeviceUsage-body-structure-code

Parameter body-structure-code:token

Code for target body structure

ResourceDeviceUsage
Expression DeviceUsage.bodyStructure.concept
Processing Mode Normal
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
http://hl7.org/fhir/SearchParameter/DeviceUsage-device

Generated Narrative: SearchParameter DeviceUsage-device

Parameter device:token

Search by device

ResourceDeviceUsage
Expression DeviceUsage.device.concept
Processing Mode Normal
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
http://hl7.org/fhir/SearchParameter/clinical-identifier
This search parameter is part of the common search parameter clinical-identifier

Generated Narrative: SearchParameter clinical-identifier

Parameter identifier:token

DeviceUsage: Search by identifier

ResourceDeviceUsage
Expression DeviceUsage.identifier
Processing Mode Normal
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
http://hl7.org/fhir/SearchParameter/clinical-patient
This search parameter is part of the common search parameter clinical-patient

Generated Narrative: SearchParameter clinical-patient

Parameter patient:reference

DeviceUsage: Search by patient who used the device

ResourceDeviceUsage
Expression DeviceUsage.subject.where(resolve() is Patient)
Processing Mode Normal
Target Resources Patient
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
http://hl7.org/fhir/SearchParameter/DeviceUsage-reference

Generated Narrative: SearchParameter DeviceUsage-reference

Parameter reference:reference

Target body structure (reference)

ResourceDeviceUsage
Expression DeviceUsage.bodyStructure.reference
Processing Mode Normal
Target Resources BodyStructure
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
http://hl7.org/fhir/SearchParameter/DeviceUsage-status

Generated Narrative: SearchParameter DeviceUsage-status

Parameter status:token

The status of the device usage

ResourceDeviceUsage
Expression DeviceUsage.status
Processing Mode Normal
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
 
http://hl7.org/fhir/SearchParameter/DeviceUsage-subject

Generated Narrative: SearchParameter DeviceUsage-subject

Parameter subject:reference

The individual(s) who used the device

ResourceDeviceUsage
Expression DeviceUsage.subject
Processing Mode Normal
Target Resources Group, Patient
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true