FHIR CI-Build

This is the Continuous Integration Build of FHIR (will be incorrect/inconsistent at times).
See the Directory of published versions

Example Device/and20601bpmonitor (Turtle)

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: No defined compartments

Raw Turtle (+ also see Turtle/RDF Format Specification)

AND20601BPMonitor

@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

[a fhir:Device ;
  fhir:nodeRole fhir:treeRoot ;
  fhir:id [ fhir:v "and20601bpmonitor"] ; # 
  fhir:text [
     fhir:status [ fhir:v "generated" ] ;
     fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Device</b><a name=\"and20601bpmonitor\"> </a><a name=\"hcand20601bpmonitor\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Device &quot;and20601bpmonitor&quot; </p></div><p><b>identifier</b>: System Identifier/00-09-1F-FF-FE-80-07-3A, Bluetooth Address/00-09-1F-80-07-3A</p><h3>UdiCarriers</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>DeviceIdentifier</b></td><td><b>Issuer</b></td><td><b>Jurisdiction</b></td><td><b>CarrierHRF</b></td><td><b>EntryType</b></td></tr><tr><td style=\"display: none\">*</td><td>39183189818</td><td><a href=\"http://hl7.org/fhir/NamingSystem/gs1-di\">http://hl7.org/fhir/NamingSystem/gs1-di</a></td><td><a href=\"http://hl7.org/fhir/NamingSystem/fda-udi\">http://hl7.org/fhir/NamingSystem/fda-udi</a></td><td>(01)39183189818(21)5091100966</td><td>unknown</td></tr></table><p><b>manufacturer</b>: A&amp;D Medical</p><p><b>serialNumber</b>: 5091100966</p><h3>Names</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Value</b></td><td><b>Type</b></td></tr><tr><td style=\"display: none\">*</td><td>AND BP UA-767PBT-C</td><td>user-friendly-name</td></tr></table><p><b>modelNumber</b>: UA-767PBT-C</p><p><b>type</b>: MDC_MOC_VMS_MDS_SIMP: Personal Health Device <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.5.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#65573 &quot;MDC_MOC_VMS_MDS_SIMP&quot;)</span></p><h3>Versions</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Type</b></td><td><b>Value</b></td></tr><tr><td style=\"display: none\">*</td><td>MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.5.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532352)</span></td><td>1.0</td></tr></table><h3>ConformsTos</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Specification</b></td><td><b>Version</b></td></tr><tr><td style=\"display: none\">*</td><td>MDC_DEV_SPEC_PROFILE_BP: Blood Pressure meter <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.5.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#528391)</span></td><td>1</td></tr></table><blockquote><p><b>property</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.5.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532353)</span></p><p><b>value</b>: 7 <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ContinuaPAN#7)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: regulation-status <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ASN1ToHL7#532354.0)</span></p><p><b>value</b>: Device is Regulated <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (v2-0136#N)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.5.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#68220)</span></p><p><b>value</b>: MDC_TIME_SYNC_NONE: No time synchronization <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.5.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532224)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: mds-time-capab-real-time-clock <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ASN1ToHL7#68219.0)</span></p><p><b>value</b>: real time clock supported <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (v2-0136#Y)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: mds-time-capab-set-clock <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ASN1ToHL7#68219.1)</span></p><p><b>value</b>: setting the time supported <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (v2-0136#Y)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: mds-time-mgr-set-time <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ASN1ToHL7#68219.11)</span></p><p><b>value</b>: manager requested to set the time <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (v2-0136#Y)</span></p></blockquote></div>"
  ] ; # 
  fhir:identifier ( [
     fhir:type [
       fhir:coding ( [
         fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "SYSID" ] ;
         fhir:display [ fhir:v "System Identifier" ]
       ] )
     ] ;
     fhir:system [ fhir:v "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680"^^xsd:anyURI ] ;
     fhir:value [ fhir:v "00-09-1F-FF-FE-80-07-3A" ]
  ] [
     fhir:type [
       fhir:coding ( [
         fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "BTMAC" ] ;
         fhir:display [ fhir:v "Bluetooth Address" ]
       ] )
     ] ;
     fhir:system [ fhir:v "http://hl7.org/fhir/sid/eui-48"^^xsd:anyURI ] ;
     fhir:value [ fhir:v "00-09-1F-80-07-3A" ]
  ] ) ; # 
  fhir:udiCarrier ( [
     fhir:deviceIdentifier [ fhir:v "39183189818" ] ;
     fhir:issuer [ fhir:v "http://hl7.org/fhir/NamingSystem/gs1-di"^^xsd:anyURI ] ;
     fhir:jurisdiction [ fhir:v "http://hl7.org/fhir/NamingSystem/fda-udi"^^xsd:anyURI ] ;
     fhir:carrierHRF [ fhir:v "(01)39183189818(21)5091100966" ] ;
     fhir:entryType [ fhir:v "unknown" ]
  ] ) ; # 
  fhir:manufacturer [ fhir:v "A&D Medical"] ; # 
  fhir:serialNumber [ fhir:v "5091100966"] ; # 
  fhir:name ( [
     fhir:value [ fhir:v "AND BP UA-767PBT-C" ] ;
     fhir:type [ fhir:v "user-friendly-name" ]
  ] ) ; # 
  fhir:modelNumber [ fhir:v "UA-767PBT-C"] ; # 
  fhir:type ( [
     fhir:coding ( [
       fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
       fhir:code [ fhir:v "65573" ] ;
       fhir:display [ fhir:v "MDC_MOC_VMS_MDS_SIMP" ]
     ] ) ;
     fhir:text [ fhir:v "MDC_MOC_VMS_MDS_SIMP: Personal Health Device" ]
  ] ) ; # 
  fhir:version ( [
     fhir:type [
       fhir:coding ( [
         fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "532352" ]
       ] ) ;
       fhir:text [ fhir:v "MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version" ]
     ] ;
     fhir:value [ fhir:v "1.0" ]
  ] ) ; # 
  fhir:conformsTo ( [
     fhir:specification [
       fhir:coding ( [
         fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "528391" ]
       ] ) ;
       fhir:text [ fhir:v "MDC_DEV_SPEC_PROFILE_BP: Blood Pressure meter" ]
     ] ;
     fhir:version [ fhir:v "1" ]
  ] ) ; # 
  fhir:property ( [
     fhir:type [
       fhir:coding ( [
         fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "532353" ]
       ] ) ;
       fhir:text [ fhir:v "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list" ]
     ] ;
     fhir:value [
       a fhir:CodeableConcept ;
       fhir:coding ( [
         fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/ContinuaPAN"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "7" ]
       ] )
     ]
  ] [
     fhir:type [
       fhir:coding ( [
         fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/ASN1ToHL7"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "532354.0" ] ;
         fhir:display [ fhir:v "regulation-status" ]
       ] )
     ] ;
     fhir:value [
       a fhir:CodeableConcept ;
       fhir:coding ( [
         fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/v2-0136"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "N" ]
       ] ) ;
       fhir:text [ fhir:v "Device is Regulated" ]
     ]
  ] [
     fhir:type [
       fhir:coding ( [
         fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "68220" ]
       ] ) ;
       fhir:text [ fhir:v "MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol" ]
     ] ;
     fhir:value [
       a fhir:CodeableConcept ;
       fhir:coding ( [
         fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "532224" ]
       ] ) ;
       fhir:text [ fhir:v "MDC_TIME_SYNC_NONE: No time synchronization" ]
     ]
  ] [
     fhir:type [
       fhir:coding ( [
         fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/ASN1ToHL7"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "68219.0" ]
       ] ) ;
       fhir:text [ fhir:v "mds-time-capab-real-time-clock" ]
     ] ;
     fhir:value [
       a fhir:CodeableConcept ;
       fhir:coding ( [
         fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/v2-0136"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "Y" ]
       ] ) ;
       fhir:text [ fhir:v "real time clock supported" ]
     ]
  ] [
     fhir:type [
       fhir:coding ( [
         fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/ASN1ToHL7"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "68219.1" ]
       ] ) ;
       fhir:text [ fhir:v "mds-time-capab-set-clock" ]
     ] ;
     fhir:value [
       a fhir:CodeableConcept ;
       fhir:coding ( [
         fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/v2-0136"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "Y" ]
       ] ) ;
       fhir:text [ fhir:v "setting the time supported" ]
     ]
  ] [
     fhir:type [
       fhir:coding ( [
         fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/ASN1ToHL7"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "68219.11" ]
       ] ) ;
       fhir:text [ fhir:v "mds-time-mgr-set-time" ]
     ] ;
     fhir:value [
       a fhir:CodeableConcept ;
       fhir:coding ( [
         fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/v2-0136"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "Y" ]
       ] ) ;
       fhir:text [ fhir:v "manager requested to set the time" ]
     ]
  ] )] . # 

# -------------------------------------------------------------------------------------


Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.