This is the Continuous Integration Build of FHIR (will be incorrect/inconsistent at times).
See the Directory of published versions
FHIR Infrastructure Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: No defined compartments |
Raw JSON (canonical form + also see JSON Format Specification)
Read Common TestScript Example
{ "resourceType" : "TestScript", "id" : "testscript-example-readcommon", "extension" : [{ "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg", "valueCode" : "fhir" }], "url" : "http://hl7.org/fhir/TestScript/testscript-example-readcommon", "identifier" : [{ "system" : "urn:ietf:rfc:3986", "value" : "urn:oid:2.16.840.1.113883.4.642.12.8" }], "version" : "1.0", "name" : "TestScript Example Read Common", "status" : "draft", "experimental" : true, "date" : "2024-04-24", "publisher" : "HL7 International / FHIR Infrastructure", "contact" : [{ "telecom" : [{ "system" : "url", "value" : "http://www.hl7.org/Special/committees/fiwg" }] }], "description" : "TestScript example resource showing the use of the common element to reuse actions within the test element. Each test will perform a Patient read operation utilizing user defined dynamic variables that will hold the Patient resource id values.", "jurisdiction" : [{ "coding" : [{ "system" : "urn:iso:std:iso:3166", "code" : "US", "display" : "United States of America" }] }], "purpose" : "Patient Read Operation", "copyright" : "© HL7.org 2011+", "scope" : [{ "artifact" : "http://hl7.org/fhir/StructureDefinition/Patient", "conformance" : { "coding" : [{ "system" : "http://hl7.org/fhir/testscript-scope-conformance-codes", "code" : "optional" }] }, "phase" : { "coding" : [{ "system" : "http://hl7.org/fhir/testscript-scope-phase-codes", "code" : "unit" }] } }], "profile" : ["http://hl7.org/fhir/StructureDefinition/Patient"], "variable" : [{ "name" : "PatientResourceId1", "defaultValue" : "f001" }, { "name" : "PatientResourceId2", "defaultValue" : "f002" }], "test" : [{ "id" : "PatientRead1", "name" : "Patient Read Test 1", "description" : "Read a known Patient (default id 'f001') and validate response using common action asserts.", "action" : [{ "operation" : { "type" : { "system" : "http://hl7.org/fhir/restful-interaction", "code" : "read" }, "resource" : "Patient", "description" : "Read the known Patient resource on the destination test system using the user defined dynamic variable ${PatientResourceId1}.", "accept" : "xml", "encodeRequestUrl" : true, "params" : "/${PatientResourceId1}" } }, { "common" : { "keyRef" : "CommonReadActionAsserts" } }] }, { "id" : "PatientRead2", "name" : "Patient Read Test 2", "description" : "Read a known Patient (default id 'f002') and validate response using common action asserts.", "action" : [{ "operation" : { "type" : { "system" : "http://hl7.org/fhir/restful-interaction", "code" : "read" }, "resource" : "Patient", "description" : "Read the known Patient resource on the destination test system using the user defined dynamic variable ${PatientResourceId2}.", "accept" : "xml", "encodeRequestUrl" : true, "params" : "/${PatientResourceId2}" } }, { "common" : { "keyRef" : "CommonReadActionAsserts" } }] }], "common" : [{ "key" : "CommonReadActionAsserts", "name" : "Common Read Action Asserts", "description" : "The common action asserts to evaluate and validate conformance to the base FHIR read operation.", "action" : [{ "assert" : { "description" : "Confirm that the returned HTTP status is 200(OK).", "response" : "okay", "stopTestOnFail" : false, "warningOnly" : false } }, { "assert" : { "description" : "Confirm that the returned format is XML.", "contentType" : "xml", "stopTestOnFail" : false, "warningOnly" : false } }, { "assert" : { "description" : "Confirm that the returned HTTP Header Last-Modified is present. Warning only as the server might not support versioning.", "headerField" : "Last-Modified", "operator" : "notEmpty", "stopTestOnFail" : false, "warningOnly" : true } }, { "assert" : { "description" : "Confirm that the returned resource type is Patient.", "resource" : "Patient", "stopTestOnFail" : false, "warningOnly" : false } }, { "assert" : { "description" : "Confirm that the returned Patient conforms to the base FHIR specification.", "stopTestOnFail" : false, "validateProfileId" : "patient-profile", "warningOnly" : false } }] }] }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR ®© HL7.org 2011+. FHIR R6 hl7.fhir.core#6.0.0-ballot2 generated on Thu, Dec 12, 2024 19:30+0000.
Links: Search |
Version History |
Contents |
Glossary |
QA |
Compare to R5 |
|
Propose a change