FHIR CI-Build

This is the Continuous Integration Build of FHIR (will be incorrect/inconsistent at times).
See the Directory of published versions

Example ObservationDefinition/example (Narrative)

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: No defined compartments

This is the narrative for the resource. See also the XML, JSON or Turtle format. This example conforms to the profile ObservationDefinition.


Generated Narrative: ObservationDefinition example

StructureDefinition Work Group: oo

status: active

publisher: HL7 International / Orders and Observations

contact: http://www.hl7.org/Special/committees/orders

category: Laboratory

code: Albumin/Protein.total in Serum or Plasma by Electrophoresis

permittedDataType: Quantity

multipleResultsAllowed: false

method: Total measurement

preferredReportName: Serum albumin/​Protein total

permittedUnit: Unified Code for Units of Measure (UCUM) %: %

qualifiedValue

context: Normal Range

rangeCategory: reference

range: 50-?

qualifiedValue

context: Normal Range

rangeCategory: critical

range: ?-40


 

 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.