Generated Thu Nov 14 00:23:51 UTC 2024, FHIR version 4.0.1 for au.digitalhealth.r4#1.2.0-ci-build (canonical = http://ns.electronichealth.net.au/fhir (history))
This page provides a report on which terminology servers were used while publishing this IG. Note that terminology caching reduces the server hit count - this page only reports content that wasn't cached
http://snomed.info/sct|http://snomed.info/sct/32506021000036107
Message | Server | ValueSet | Systems | Choices |
System not handled by any servers. Using primary server | http://tx.fhir.org/r4 | null | http://hl7.org/fhir/fhir-types | auth = , candidates= |
Fallback: primary server | http://tx.fhir.org/r4 | null | http://hl7.org/fhir/fhir-types | auth = , candidates= |
Found candidate server http://tx.fhir.org/r4 | http://tx.fhir.org/r4 | http://hl7.org/fhir/ValueSet/jurisdiction|4.0.1 | [http://unstats.un.org/unsd/methods/m49/m49.htm, urn:iso:std:iso:3166, urn:iso:std:iso:3166:-2] | [auth = , candidates=http://tx.fhir.org/r4, auth = , candidates=http://tx.fhir.org/r4, auth = , candidates=http://tx.fhir.org/r4] |
Found candidate server http://tx.fhir.org/r4 | http://tx.fhir.org/r4 | https://healthterminologies.gov.au/fhir/ValueSet/indicator-hypersensitivity-intolerance-to-substance-2 | http://loinc.org | auth = , candidates=http://tx.fhir.org/r4|https://tx.ontoserver.csiro.au/fhir |
Found authoritative server https://tx.ontoserver.csiro.au/fhir | https://tx.ontoserver.csiro.au/fhir | https://healthterminologies.gov.au/fhir/ValueSet/indicator-hypersensitivity-intolerance-to-substance-2|2.1.0 | http://snomed.info/sct | auth = https://tx.ontoserver.csiro.au/fhir, candidates=http://tx.fhir.org/r4 |
Found authoritative server https://tx.ontoserver.csiro.au/fhir | https://tx.ontoserver.csiro.au/fhir | null | http://snomed.info/sct | auth = https://tx.ontoserver.csiro.au/fhir, candidates=http://tx.fhir.org/r4 |
Found authoritative server https://tx.ontoserver.csiro.au/fhir | https://tx.ontoserver.csiro.au/fhir | https://healthterminologies.gov.au/fhir/ValueSet/adverse-reaction-agent-1--0|1.1.1 | http://snomed.info/sct | auth = https://tx.ontoserver.csiro.au/fhir, candidates=http://tx.fhir.org/r4 |
Found authoritative server https://tx.ontoserver.csiro.au/fhir | https://tx.ontoserver.csiro.au/fhir | null | http://snomed.info/sct | auth = https://tx.ontoserver.csiro.au/fhir, candidates=http://tx.fhir.org/r4 |
Found authoritative server https://tx.ontoserver.csiro.au/fhir | https://tx.ontoserver.csiro.au/fhir | https://healthterminologies.gov.au/fhir/ValueSet/clinical-finding-1--0|1.0.2 | http://snomed.info/sct | auth = https://tx.ontoserver.csiro.au/fhir, candidates=http://tx.fhir.org/r4 |
Found authoritative server https://tx.ontoserver.csiro.au/fhir | https://tx.ontoserver.csiro.au/fhir | https://healthterminologies.gov.au/fhir/ValueSet/indicator-hypersensitivity-intolerance-to-substance-2|2.1.0 | http://snomed.info/sct | auth = https://tx.ontoserver.csiro.au/fhir, candidates=http://tx.fhir.org/r4 |
Found authoritative server https://tx.ontoserver.csiro.au/fhir | https://tx.ontoserver.csiro.au/fhir | https://healthterminologies.gov.au/fhir/ValueSet/indicator-hypersensitivity-intolerance-to-substance-2|2.1.0 | http://snomed.info/sct | auth = https://tx.ontoserver.csiro.au/fhir, candidates=http://tx.fhir.org/r4 |
Found authoritative server https://tx.ontoserver.csiro.au/fhir | https://tx.ontoserver.csiro.au/fhir | https://healthterminologies.gov.au/fhir/ValueSet/indicator-hypersensitivity-intolerance-to-substance-2|2.1.0 | http://snomed.info/sct | auth = https://tx.ontoserver.csiro.au/fhir, candidates=http://tx.fhir.org/r4 |
Found authoritative server https://tx.ontoserver.csiro.au/fhir | https://tx.ontoserver.csiro.au/fhir | null | http://snomed.info/sct | auth = https://tx.ontoserver.csiro.au/fhir, candidates=http://tx.fhir.org/r4 |
Found authoritative server https://tx.ontoserver.csiro.au/fhir | https://tx.ontoserver.csiro.au/fhir | https://healthterminologies.gov.au/fhir/ValueSet/clinical-finding-1--0|1.0.2 | http://snomed.info/sct | auth = https://tx.ontoserver.csiro.au/fhir, candidates=http://tx.fhir.org/r4 |
Found candidate server http://tx.fhir.org/r4 | http://tx.fhir.org/r4 | http://hl7.org/fhir/ValueSet/jurisdiction|4.0.1 | [http://unstats.un.org/unsd/methods/m49/m49.htm, urn:iso:std:iso:3166, urn:iso:std:iso:3166:-2] | [auth = , candidates=http://tx.fhir.org/r4, auth = , candidates=http://tx.fhir.org/r4, auth = , candidates=http://tx.fhir.org/r4] |
Found candidate server http://tx.fhir.org/r4 | http://tx.fhir.org/r4 | urn:iso:std:iso:3166 | auth = , candidates=http://tx.fhir.org/r4 | |
Found candidate server http://tx.fhir.org/r4 | http://tx.fhir.org/r4 | urn:iso:std:iso:3166 | auth = , candidates=http://tx.fhir.org/r4 | |
Found candidate server http://tx.fhir.org/r4 | http://tx.fhir.org/r4 | urn:iso:std:iso:3166 | auth = , candidates=http://tx.fhir.org/r4 | |
Found candidate server http://tx.fhir.org/r4 | http://tx.fhir.org/r4 | urn:iso:std:iso:3166:-2 | auth = , candidates=http://tx.fhir.org/r4 |
Use Count: 8. Code Systems used:
System | #Exp. | #Val. | Details |
---|---|---|---|
http://hl7.org/fhir/fhir-types | 0 | 1 | |
http://loinc.org | 0 | 1 | Logical Observation Identifiers, Names and Codes (LOINC) |
http://unstats.un.org/unsd/methods/m49/m49.htm | 0 | 2 | |
urn:iso:std:iso:3166 | 3 | 2 | ISO 3166-1 Codes for the representation of names of countries and their subdivisions — Part 1: Country code |
urn:iso:std:iso:3166:-2 | 1 | 2 | ISO 3166 Part 2 Country Subdivision Codes |
Use Count: 22. Code Systems used:
System | #Exp. | #Val. | Details |
---|---|---|---|
http://snomed.info/sct | 0 | 10 | SNOMED CT (all versions) |