CH EPR mHealth (R4)
4.0.0-ci-build - DSTU3
CH EPR mHealth (R4), published by eHealth Suisse. This guide is not an authorized publication; it is the continuous build for version 4.0.0-ci-build built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/qligier/ch-epr-mhealth/ and changes regularly. See the Directory of published versions
{
"resourceType" : "AuditEvent",
"id" : "ex-auditProvideBundle-source",
"meta" : {
"profile" : [
🔗 "https://profiles.ihe.net/ITI/MHD/StructureDefinition/IHE.MHD.ProvideBundle.Audit.Source"
],
"security" : [
{
"system" : "http://terminology.hl7.org/CodeSystem/v3-ActReason",
"code" : "HTEST"
}
]
},
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: AuditEvent ex-auditProvideBundle-source</b></p><a name=\"ex-auditProvideBundle-source\"> </a><a name=\"hcex-auditProvideBundle-source\"> </a><a name=\"ex-auditProvideBundle-source-en-US\"> </a><p><b>type</b>: <a href=\"http://hl7.org/fhir/R4/codesystem-dicom-dcim.html#dicom-dcim-110106\">DICOM 110106</a>: Export</p><p><b>subtype</b>: unknown ITI-65: Provide Document Bundle</p><p><b>action</b>: Read/View/Print</p><p><b>recorded</b>: 2020-06-29 12:01:30+0000</p><p><b>outcome</b>: Success</p><p><b>purposeOfEvent</b>: <span title=\"Codes:{urn:oid:2.16.756.5.30.1.127.3.10.5 NORM}\">Normal Access</span></p><blockquote><p><b>agent</b></p><p><b>type</b>: <span title=\"Codes:{http://dicom.nema.org/resources/ontology/DCM 110153}\">Source Role ID</span></p><p><b>who</b>: ihe-sourceId</p><p><b>requestor</b>: false</p><h3>Networks</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Address</b></td><td><b>Type</b></td></tr><tr><td style=\"display: none\">*</td><td>myDevice.example.com</td><td>Machine Name</td></tr></table></blockquote><blockquote><p><b>agent</b></p><p><b>type</b>: <span title=\"Codes:{http://dicom.nema.org/resources/ontology/DCM 110152}\">Destination Role ID</span></p><p><b>who</b>: myMachine.example.org</p><p><b>requestor</b>: false</p><h3>Networks</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Address</b></td><td><b>Type</b></td></tr><tr><td style=\"display: none\">*</td><td>http://server.example.com/fhir</td><td>URI</td></tr></table></blockquote><blockquote><p><b>agent</b></p><p><b>type</b>: <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/v3-RoleClass PROV}\">healthcare provider</span></p><p><b>role</b>: <span title=\"Codes:{urn:oid:2.16.756.5.30.1.127.3.10.6 HCP}\">Healthcare professional</span></p><p><b>who</b>: Identifier: <code>urn:gs1:gln</code>/2000000090108</p><p><b>name</b>: Martina Musterarzt</p><p><b>requestor</b>: true</p><p><b>policy</b>: c5436729-3f26-4dbf-abd3-2790dc7771a</p></blockquote><h3>Sources</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Site</b></td><td><b>Observer</b></td><td><b>Type</b></td></tr><tr><td style=\"display: none\">*</td><td>1.3.6.1.4.1.12559.11.13.2.5</td><td>ihe-sourceId</td><td><a href=\"http://terminology.hl7.org/5.4.0/CodeSystem-security-source-type.html#security-source-type-1\">Audit Event Source Type 1</a>: User Device</td></tr></table><blockquote><p><b>entity</b></p><p><b>what</b>: <a href=\"http://example.org/Patient/FranzMusterNeedsAbsoluteUrl\">http://example.org/Patient/FranzMusterNeedsAbsoluteUrl</a></p><p><b>type</b>: <a href=\"http://terminology.hl7.org/5.4.0/CodeSystem-audit-entity-type.html#audit-entity-type-1\">Audit event entity type 1</a>: Person</p><p><b>role</b>: <a href=\"http://terminology.hl7.org/5.4.0/CodeSystem-object-role.html#object-role-1\">AuditEventEntityRole 1</a>: Patient</p></blockquote><blockquote><p><b>entity</b></p><p><b>what</b>: Identifier: <a href=\"http://terminology.hl7.org/3.1.0/NamingSystem-uri.html\" title=\"As defined by RFC 3986 (http://www.ietf.org/rfc/rfc3986.txt)(with many schemes defined in many RFCs). For OIDs and UUIDs, use the URN form (urn:oid:(note: lowercase) and urn:uuid:). See http://www.ietf.org/rfc/rfc3001.txt and http://www.ietf.org/rfc/rfc4122.txt \r\n\r\nThis oid is used as an identifier II.root to indicate the the extension is an absolute URI (technically, an IRI). Typically, this is used for OIDs and GUIDs. Note that when this OID is used with OIDs and GUIDs, the II.extension should start with urn:oid or urn:uuid: \r\n\r\nNote that this OID is created to aid with interconversion between CDA and FHIR - FHIR uses urn:ietf:rfc:3986 as equivalent to this OID. URIs as identifiers appear more commonly in FHIR.\r\n\r\nThis OID may also be used in CD.codeSystem.\">URI</a>/urn:oid:1.3.6.1.4.1.12559.11.13.2.6.2949</p><p><b>type</b>: <a href=\"http://terminology.hl7.org/5.4.0/CodeSystem-audit-entity-type.html#audit-entity-type-2\">Audit event entity type 2</a>: System Object</p><p><b>role</b>: <a href=\"http://terminology.hl7.org/5.4.0/CodeSystem-object-role.html#object-role-20\">AuditEventEntityRole 20</a>: Job</p></blockquote><blockquote><p><b>entity</b></p><p><b>what</b>: Identifier: 00-0af7651916cd43dd8448eb211c80319c-b7ad6b7169203331-01</p><p><b>type</b>: <a href=\"https://profiles.ihe.net/ITI/BALP/1.1.0/CodeSystem-BasicAuditEntityType.html#BasicAuditEntityType-Traceparent\">Entity Types that are defined in IHE BasicAudit Traceparent</a>: Traceparent</p></blockquote></div>"
},
"type" : {
"system" : "http://dicom.nema.org/resources/ontology/DCM",
"code" : "110106",
"display" : "Export"
},
"subtype" : [
{
"system" : "urn:ihe:event-type-code",
"code" : "ITI-65",
"display" : "Provide Document Bundle"
}
],
"action" : "R",
"recorded" : "2020-06-29T12:01:30+00:00",
"outcome" : "0",
"purposeOfEvent" : [
{
"coding" : [
{
"system" : "urn:oid:2.16.756.5.30.1.127.3.10.5",
"code" : "NORM",
"display" : "Normal Access"
}
]
}
],
"agent" : [
{
"type" : {
"coding" : [
{
"system" : "http://dicom.nema.org/resources/ontology/DCM",
"code" : "110153",
"display" : "Source Role ID"
}
]
},
"who" : {
"display" : "ihe-sourceId"
},
"requestor" : false,
"network" : {
"address" : "myDevice.example.com",
"type" : "1"
}
},
{
"type" : {
"coding" : [
{
"system" : "http://dicom.nema.org/resources/ontology/DCM",
"code" : "110152",
"display" : "Destination Role ID"
}
]
},
"who" : {
"display" : "myMachine.example.org"
},
"requestor" : false,
"network" : {
"address" : "http://server.example.com/fhir",
"type" : "5"
}
},
{
"type" : {
"coding" : [
{
"system" : "http://terminology.hl7.org/CodeSystem/v3-RoleClass",
"code" : "PROV",
"display" : "healthcare provider"
}
]
},
"role" : [
{
"coding" : [
{
"system" : "urn:oid:2.16.756.5.30.1.127.3.10.6",
"code" : "HCP",
"display" : "Healthcare professional"
}
]
}
],
"who" : {
"identifier" : {
"system" : "urn:gs1:gln",
"value" : "2000000090108"
}
},
"name" : "Martina Musterarzt",
"requestor" : true,
"policy" : [
"c5436729-3f26-4dbf-abd3-2790dc7771a"
]
}
],
"source" : {
"site" : "1.3.6.1.4.1.12559.11.13.2.5",
"observer" : {
"display" : "ihe-sourceId"
},
"type" : [
{
"system" : "http://terminology.hl7.org/CodeSystem/security-source-type",
"code" : "1",
"display" : "User Device"
}
]
},
"entity" : [
{
"what" : {
"reference" : "http://example.org/Patient/FranzMusterNeedsAbsoluteUrl"
},
"type" : {
"system" : "http://terminology.hl7.org/CodeSystem/audit-entity-type",
"code" : "1",
"display" : "Person"
},
"role" : {
"system" : "http://terminology.hl7.org/CodeSystem/object-role",
"code" : "1",
"display" : "Patient"
}
},
{
"what" : {
"identifier" : {
"system" : "urn:ietf:rfc:3986",
"value" : "urn:oid:1.3.6.1.4.1.12559.11.13.2.6.2949"
}
},
"type" : {
"system" : "http://terminology.hl7.org/CodeSystem/audit-entity-type",
"code" : "2",
"display" : "System Object"
},
"role" : {
"system" : "http://terminology.hl7.org/CodeSystem/object-role",
"code" : "20",
"display" : "Job"
}
},
{
"what" : {
"identifier" : {
"value" : "00-0af7651916cd43dd8448eb211c80319c-b7ad6b7169203331-01"
}
},
"type" : {
"system" : "https://profiles.ihe.net/ITI/BALP/CodeSystem/BasicAuditEntityType",
"code" : "Traceparent"
}
}
]
}