OpenEHR Base package
0.1.0 - First Draft International flag

OpenEHR Base package, published by openEHR + HL7. This guide is not an authorized publication; it is the continuous build for version 0.1.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/openehr-fhir/base-spec/ and changes regularly. See the Directory of published versions

Logical Model: AUDIT_DETAILS - Detailed Descriptions

Page standards status: Informative Maturity Level: 3

Definitions for the AUDIT-DETAILS logical model.

Guidance on how to interpret the contents of this table can be foundhere

0. AUDIT_DETAILS
Definition

The set of attributes required to document the committal of an information item to a repository.


Base definition for all types defined in FHIR type system.

ShortThe set of attributes required to document the committal of an information item to a repository.Base for all types and resources
Control0..*
Is Modifierfalse
Logical ModelInstances of this logical model are not marked to be the target of a Reference
InvariantsSystem_id_valid: System id valid must not be empty (system_id.empty().not())
Change_type_valid: Change type valid (null # TODO: manual translation needed)
2. AUDIT_DETAILS.system-id
Definition

Identifier of the logical EHR system where the change was committed. This is almost always owned by the organisation legally responsible for the EHR, and is distinct from any application, or any hosting infrastructure.

ShortIdentifier of the logical EHR system where the change was committed.
Control1..1
Typestring
Is Modifierfalse
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
4. AUDIT_DETAILS.time-committed
Definition

Time of committal of the item.

ShortTime of committal of the item.
Control1..1
Typehttp://openehr.org/fhir/StructureDefinition/DV-DATE-TIME
Is Modifierfalse
6. AUDIT_DETAILS.change-type
Definition

Type of change. Coded using the openEHR Terminology audit change type group.

ShortType of change.
Control1..1
Typehttp://openehr.org/fhir/StructureDefinition/DV-CODED-TEXT
Is Modifierfalse
8. AUDIT_DETAILS.description
Definition

Reason for committal. This may be used to qualify the value in the _change_type_ field. For example, if the change affects only the EHR directory, this field might be used to indicate 'Folder "episode 2018-02-16" added' or similar.

ShortReason for committal.
Control0..1
Typehttp://openehr.org/fhir/StructureDefinition/DV-TEXT
Is Modifierfalse
10. AUDIT_DETAILS.committer
Definition

Identity and optional reference into identity management service, of user who committed the item.

ShortIdentity and optional reference into identity management service, of user who committed the item.
Control1..1
Typehttp://openehr.org/fhir/StructureDefinition/PARTY-PROXY
Is Modifierfalse

Guidance on how to interpret the contents of this table can be foundhere

0. AUDIT_DETAILS
Definition

The set of attributes required to document the committal of an information item to a repository.

ShortThe set of attributes required to document the committal of an information item to a repository.
Control0..*
Is Modifierfalse
Logical ModelInstances of this logical model are not marked to be the target of a Reference
InvariantsSystem_id_valid: System id valid must not be empty (system_id.empty().not())
Change_type_valid: Change type valid (null # TODO: manual translation needed)
2. AUDIT_DETAILS.system-id
Definition

Identifier of the logical EHR system where the change was committed. This is almost always owned by the organisation legally responsible for the EHR, and is distinct from any application, or any hosting infrastructure.

ShortIdentifier of the logical EHR system where the change was committed.
Control1..1
Typestring
Is Modifierfalse
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
4. AUDIT_DETAILS.time-committed
Definition

Time of committal of the item.

ShortTime of committal of the item.
Control1..1
Typehttp://openehr.org/fhir/StructureDefinition/DV-DATE-TIME
Is Modifierfalse
6. AUDIT_DETAILS.change-type
Definition

Type of change. Coded using the openEHR Terminology audit change type group.

ShortType of change.
Control1..1
Typehttp://openehr.org/fhir/StructureDefinition/DV-CODED-TEXT
Is Modifierfalse
8. AUDIT_DETAILS.description
Definition

Reason for committal. This may be used to qualify the value in the _change_type_ field. For example, if the change affects only the EHR directory, this field might be used to indicate 'Folder "episode 2018-02-16" added' or similar.

ShortReason for committal.
Control0..1
Typehttp://openehr.org/fhir/StructureDefinition/DV-TEXT
Is Modifierfalse
10. AUDIT_DETAILS.committer
Definition

Identity and optional reference into identity management service, of user who committed the item.

ShortIdentity and optional reference into identity management service, of user who committed the item.
Control1..1
Typehttp://openehr.org/fhir/StructureDefinition/PARTY-PROXY
Is Modifierfalse

Guidance on how to interpret the contents of this table can be foundhere

0. AUDIT_DETAILS
Definition

The set of attributes required to document the committal of an information item to a repository.

ShortThe set of attributes required to document the committal of an information item to a repository.
Control0..*
Is Modifierfalse
Logical ModelInstances of this logical model are not marked to be the target of a Reference
InvariantsSystem_id_valid: System id valid must not be empty (system_id.empty().not())
Change_type_valid: Change type valid (null # TODO: manual translation needed)
2. AUDIT_DETAILS.system-id
Definition

Identifier of the logical EHR system where the change was committed. This is almost always owned by the organisation legally responsible for the EHR, and is distinct from any application, or any hosting infrastructure.

ShortIdentifier of the logical EHR system where the change was committed.
Control1..1
Typestring
Is Modifierfalse
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
4. AUDIT_DETAILS.time-committed
Definition

Time of committal of the item.

ShortTime of committal of the item.
Control1..1
Typehttp://openehr.org/fhir/StructureDefinition/DV-DATE-TIME
Is Modifierfalse
6. AUDIT_DETAILS.change-type
Definition

Type of change. Coded using the openEHR Terminology audit change type group.

ShortType of change.
Control1..1
Typehttp://openehr.org/fhir/StructureDefinition/DV-CODED-TEXT
Is Modifierfalse
8. AUDIT_DETAILS.description
Definition

Reason for committal. This may be used to qualify the value in the _change_type_ field. For example, if the change affects only the EHR directory, this field might be used to indicate 'Folder "episode 2018-02-16" added' or similar.

ShortReason for committal.
Control0..1
Typehttp://openehr.org/fhir/StructureDefinition/DV-TEXT
Is Modifierfalse
10. AUDIT_DETAILS.committer
Definition

Identity and optional reference into identity management service, of user who committed the item.

ShortIdentity and optional reference into identity management service, of user who committed the item.
Control1..1
Typehttp://openehr.org/fhir/StructureDefinition/PARTY-PROXY
Is Modifierfalse