HL7 Electronic Health Record System Functional Model, Release 2.1.1
2.1.1 - International flag

HL7 Electronic Health Record System Functional Model, Release 2.1.1, published by HL7 International / Electronic Health Records. This guide is not an authorized publication; it is the continuous build for version 2.1.1 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/mvdzel/ehrsfm-fhir-r5/ and changes regularly. See the Directory of published versions

Requirements: TI.2.1.2.6 User Access (Successful) Security Audit Trigger (Function)

Official URL: http://hl7.org/ehrs/uv/ehrsfmr2/Requirements/EHRSFMR2-TI.2.1.2.6 Version: 2.1.1
Standards status: Normative Active as of 2025-10-31 Computable Name: TI_2_1_2_6_User_Access__Successful__Security_Audit_Trigger

Manage Audit Trigger initiated to track user access (successful).

Statement N:

Manage Audit Trigger initiated to track user access (successful).

Description I:

Capture user access (successful), both routine and exceptional, including key metadata (who, what, when, where, why).

Criteria N:
TI.2.1.2.6#01
SHALL

The system SHALL audit each occurrence when user access is successful.

TI.2.1.2.6#02
SHALL

The system SHALL capture identity of the organization.

TI.2.1.2.6#03
conditional
SHALL

IF known, THEN the system SHALL capture identity of the user.

TI.2.1.2.6#04
SHALL

The system SHALL capture identity of the system.

TI.2.1.2.6#05
SHALL

The system SHALL capture the event initiating audit trigger.

TI.2.1.2.6#06
SHALL

The system SHALL capture the date and time of the event initiating audit trigger.

TI.2.1.2.6#07
SHALL

The system SHALL capture identity of the location (i.e., network address).