HL7 Electronic Health Record System Functional Model, Release 2.1.1, published by HL7 International / Electronic Health Records. This guide is not an authorized publication; it is the continuous build for version 2.1.1 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/mvdzel/ehrsfm-fhir-r5/ and changes regularly. See the Directory of published versions

Requirements: RI.1.1.8.1 Evidence of Record Entry Transmit Event (Function)

Official URL: http://hl7.org/ehrs/uv/ehrsfmr2/Requirements/EHRSFMR2-RI.1.1.8.1 Version: 2.1.1
Standards status: Normative Active as of 2025-10-31 Computable Name: RI_1_1_8_1_Evidence_of_Record_Entry_Transmit_Event

Maintain Evidence of Record Entry Transmit Event

Statement N:

Maintain Evidence of Record Entry Transmit Event

Description I:

Evidence of Record Entry Transmit Event includes key metadata, ensures health record integrity (and trust) and enables record audit.

Criteria N:
RI.1.1.8.1#01
SHALL

The system SHALL audit each occurrence when Record Entry content is transmitted.

RI.1.1.8.1#02
SHALL

The system SHALL capture identity of the organization from which Record Entry content is transmitted.

RI.1.1.8.1#03
SHALL

The system SHALL capture identity of the patient who is subject of Record Entry content transmitted.

RI.1.1.8.1#04
SHALL

The system SHALL capture identity of the user initiating transmission of Record Entry content.

RI.1.1.8.1#05
SHALL

The system SHALL capture identity of the system application which transmitted Record Entry content.

RI.1.1.8.1#06
SHALL

The system SHALL capture identity of the system application which received Record Entry content.

RI.1.1.8.1#07
SHALL

The system SHALL capture the type of Record Event trigger (i.e., transmit).

RI.1.1.8.1#08
SHALL

The system SHALL capture the date and time Record Entry content is transmitted.

RI.1.1.8.1#09
SHOULD

The system SHOULD capture identity of the location (i.e., network address) from which the Record Entry is transmitted/disclosed.

RI.1.1.8.1#10
SHALL

The system SHALL capture the location (network address) to which the Record Entry is transmitted/disclosed.

RI.1.1.8.1#11
MAY

The system MAY capture the rationale for transmitting Record Entry content.

RI.1.1.8.1#12
SHALL

The system SHALL capture the type of Record Entry content transmitted/disclosed (e.g., original, amended, updated data).

RI.1.1.8.1#13
MAY

The system MAY capture the data, document or other identifier for transmitted/disclosed Record Entry.

RI.1.1.8.1#14
MAY

The system MAY capture data elements for transmitted/disclosed Record Entry.

RI.1.1.8.1#15
dependent
SHALL

The system SHALL capture when a Record Entry transmit occurrence is known to be a disclosure, according to scope of practice, organizational policy, and/or jurisdictional law.

RI.1.1.8.1#16
SHOULD

The system SHOULD capture known and applicable permissions regarding Record Entry content transmitted including confidentiality codes, patient consent authorizations, privacy policy pointers.