HL7 Electronic Health Record System Functional Model, Release 2.1.1
            
            2.1.1 - 
  
            
          
HL7 Electronic Health Record System Functional Model, Release 2.1.1, published by HL7 International / Electronic Health Records. This guide is not an authorized publication; it is the continuous build for version 2.1.1 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/mvdzel/ehrsfm-fhir-r5/ and changes regularly. See the Directory of published versions
| Official URL: http://hl7.org/ehrs/uv/ehrsfmr2/Requirements/EHRSFMR2-RI.1.1.13.1 | Version: 2.1.1 | |||
| Standards status: Normative Active as of 2025-10-31 | Computable Name: RI_1_1_13_1_Evidence_of_Record_Entry_Extraction_Event | |||
Maintain Evidence of Record Entry Extraction Event
Maintain Evidence of Record Entry Extraction Event
Evidence of Record Entry Extraction Events includes key metadata, ensures health record integrity (and trust) and enables record audit.
| 
                
                 RI.1.1.13.1#01 
                
             | 
            
                
                
                
                 SHALL 
                
             | 
            
                
                 The system SHALL audit each occurrence when Record Entry content is extracted.  | 
        
| 
                
                 RI.1.1.13.1#02 
                
             | 
            
                
                
                
                 SHALL 
                
             | 
            
                
                 The system SHALL capture identity of the organization where Record Entry content is extracted.  | 
        
| 
                
                 RI.1.1.13.1#03 
                
             | 
            
                
                
                
                 SHALL 
                
             | 
            
                
                 The system SHALL capture identity of the patient who is subject of extracted Record Entry content.  | 
        
| 
                
                 RI.1.1.13.1#04 
                
             | 
            
                
                
                
                 SHALL 
                
             | 
            
                
                 The system SHALL capture identity of the user extracting Record Entry content.  | 
        
| 
                
                 RI.1.1.13.1#05 
                
             | 
            
                
                
                
                 SHALL 
                
             | 
            
                
                 The system SHALL capture identity of the system application which extracted Record Entry content.  | 
        
| 
                
                 RI.1.1.13.1#06 
                
             | 
            
                
                
                
                 SHALL 
                
             | 
            
                
                 The system SHALL capture the type of Record Event trigger (i.e., extract).  | 
        
| 
                
                 RI.1.1.13.1#07 
                
             | 
            
                
                
                
                 SHALL 
                
             | 
            
                
                 The system SHALL capture the date and time Record Entry content is extracted.  | 
        
| 
                
                 RI.1.1.13.1#08 
                
             | 
            
                
                
                
                 SHOULD 
                
             | 
            
                
                 The system SHOULD capture identity of the location (i.e., network address) where Record Entry content is extracted.  | 
        
| 
                
                 RI.1.1.13.1#09 
                
             | 
            
                
                
                
                 MAY 
                
             | 
            
                
                 The system MAY capture the rationale for extracting Record Entry content.  |