ISO/HL7 10781 - Electronic Health Record System Functional Model, Release 2.1
2.1.0 - local International flag

Publish Box goes here

Requirements: TI.2.1.3.9 Maintenance Started System Audit Trigger (Function)

Active as of 2024-11-26
Statement N:

Manage Audit Trigger initiated to track maintenance started event.

Description I:

Capture maintenance started event, both routine and exceptional, including key metadata (who, what, when, where, why).

Criteria N:
TI.2.1.3.9#01 SHALL

The system SHALL audit each occurrence when maintenance is initiated, including down time.

TI.2.1.3.9#02 SHALL

The system SHALL capture identity of the organization.

TI.2.1.3.9#03 conditional SHALL

IF known, THEN the system SHALL capture identity of the user.

TI.2.1.3.9#04 SHALL

The system SHALL capture identity of the system.

TI.2.1.3.9#05 SHALL

The system SHALL capture the event initiating audit trigger.

TI.2.1.3.9#06 SHALL

The system SHALL capture the date and time of the event initiating audit trigger.

TI.2.1.3.9#07 SHALL

The system SHALL capture identity of the location (i.e., network address).