Statement N:

Manage Audit Trigger initiated to track back-up started event.

Description I:

Capture back-up started event, both routine and exceptional, including key metadata (who, what, when, where, why).

Criteria N:
TI.2.1.3.3#01 SHALL

The system SHALL audit each occurrence when database backup is initiated.

TI.2.1.3.3#02 SHALL

The system SHALL capture identity of the organization.

TI.2.1.3.3#03 conditional SHALL

IF known, THEN the system SHALL capture identity of the user.

TI.2.1.3.3#04 SHALL

The system SHALL capture identity of the system.

TI.2.1.3.3#05 SHALL

The system SHALL capture the event initiating audit trigger.

TI.2.1.3.3#06 SHALL

The system SHALL capture the date and time of the event initiating audit trigger.

TI.2.1.3.3#07 SHALL

The system SHALL capture identity of the location (i.e., network address).