ISO/HL7 10781 - Electronic Health Record System Functional Model, Release 2.1
2.1.0 - local International flag

Publish Box goes here

Requirements: RI.1.1.27 Decrypt Record Entries (Function)

Active as of 2024-11-26
Statement N:

Decrypt Records Entries (1 or more instances)

Description I:

Decrypt Record Lifecycle Event - occurs when an agent causes the system to decode record entry content from a cipher.

Reference: ISO 21089-2018, Section 15.27.

Criteria N:
RI.1.1.27#01 SHALL

The system SHALL provide the ability to render decrypted Record Entry content based on a cipher.

RI.1.1.27#02 SHOULD

The system SHOULD maintain the original and all previous versions of the Record Entry, retaining each version instance without alteration.

RI.1.1.27#03 SHOULD

The system SHOULD capture a new uniquely identifiable version of the Record Entry, incorporating decrypted content.