ISO/HL7 10781 - Electronic Health Record System Functional Model, Release 2.1
2.1.0 - local International flag

Publish Box goes here

: CPS.6.3 Support for Safe Blood Administration (Function) - XML Representation

Active as of 2024-11-26

Raw xml | Download


<Requirements xmlns="http://hl7.org/fhir">
  <id value="EHRSFMR2.1-CPS.6.3"/>
  <meta>
    <profile value="http://hl7.org/ehrs/StructureDefinition/FMFunction"/>
  </meta>
  <text>
    <status value="extensions"/>
    <div xmlns="http://www.w3.org/1999/xhtml">
    <span id="description"><b>Statement <a href="https://hl7.org/fhir/versions.html#std-process" title="Normative Content" class="normative-flag">N</a>:</b> <div><p>Facilitate real-time checks for potential blood administration errors.</p>
</div></span>

    
    <span id="purpose"><b>Description <a href="https://hl7.org/fhir/versions.html#std-process" title="Informative Content" class="informative-flag">I</a>:</b> <div><p>To reduce errors at the time of blood product administration, the system assists in positive patient identification, along with checks and alerts regarding the blood product to be administered, including the identification of the blood product, the amount to be delivered, and the route and time of the administration of the blood product.</p>
</div></span>
    

    

    
    <span id="requirements"><b>Criteria <a href="https://hl7.org/fhir/versions.html#std-process" title="Normative Content" class="normative-flag">N</a>:</b></span>
    
    <table id="statements" class="grid dict">
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>CPS.6.3#01</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                
                
                <span>SHALL</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHALL present, at the time of administration, information necessary to correctly identify the patient and accurately administer blood products including patient name, blood product number, amount, route, product expiration date and time of administration.</p>
</div></span>
                
                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>CPS.6.3#02</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                
                
                <span>SHALL</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHALL provide the ability to capture validation of the correct matching of the patient to the blood product.</p>
</div></span>
                
                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>CPS.6.3#03</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                
                
                <span>SHALL</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHALL provide the ability to capture the blood product number, amount, route and time of administration.</p>
</div></span>
                
                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>CPS.6.3#04</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                
                
                <span>SHALL</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHALL conform to function [[CP.3.2]] (Manage Patient Clinical Measurements) and capture the blood pressure, temperature, pulse and respiration rate of the patient receiving the product.</p>
</div></span>
                
                
            </td>
        </tr>
        
    </table>
</div>
  </text>
  <url value="http://hl7.org/ehrs/Requirements/EHRSFMR2.1-CPS.6.3"/>
  <version value="2.1.0"/>
  <name value="CPS_6_3_Support_for_Safe_Blood_Administration"/>
  <title value="CPS.6.3 Support for Safe Blood Administration (Function)"/>
  <status value="active"/>
  <date value="2024-11-26T16:30:50+00:00"/>
  <publisher value="EHR WG"/>
  <contact>
    <telecom>
      <system value="url"/>
      <value value="http://www.hl7.org/Special/committees/ehr"/>
    </telecom>
  </contact>
  <description
               value="Facilitate real-time checks for potential blood administration errors."/>
  <jurisdiction>
    <coding>
      <system value="http://unstats.un.org/unsd/methods/m49/m49.htm"/>
      <code value="001"/>
      <display value="World"/>
    </coding>
  </jurisdiction>
  <purpose
           value="To reduce errors at the time of blood product administration, the system assists in positive patient identification, along with checks and alerts regarding the blood product to be administered, including the identification of the blood product, the amount to be delivered, and the route and time of the administration of the blood product."/>
  <statement>
    <extension
               url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="EHRSFMR2.1-CPS.6.3-01"/>
    <label value="CPS.6.3#01"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL present, at the time of administration, information necessary to correctly identify the patient and accurately administer blood products including patient name, blood product number, amount, route, product expiration date and time of administration."/>
    <derivedFrom value="EHR-S_FM_R1.1 DC.2.4.5.1#1"/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="EHRSFMR2.1-CPS.6.3-02"/>
    <label value="CPS.6.3#02"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL provide the ability to capture validation of the correct matching of the patient to the blood product."/>
    <derivedFrom value="EHR-S_FM_R1.1 DC.2.4.5.1#2"/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="EHRSFMR2.1-CPS.6.3-03"/>
    <label value="CPS.6.3#03"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL provide the ability to capture the blood product number, amount, route and time of administration."/>
    <derivedFrom value="EHR-S_FM_R1.1 DC.2.4.5.1#3"/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="EHRSFMR2.1-CPS.6.3-04"/>
    <label value="CPS.6.3#04"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL conform to function [[CP.3.2]] (Manage Patient Clinical Measurements) and capture the blood pressure, temperature, pulse and respiration rate of the patient receiving the product."/>
    <derivedFrom value="EHR-S_FM_R1.1 DC.2.4.5.1#4"/>
  </statement>
</Requirements>