Generated Fri Jan 31 17:01:43 UTC 2025, FHIR version 4.0.1 for medcom.fhir.dk.xdsmetadata#1.0.1 (canonical = http://medcomfhir.dk/ig/xdsmetadata (history)). See Errors Only
Quality Checks | |||||||||||||||||||||||||
Publisher Version: | IG Publisher Version: v1.8.10 | ||||||||||||||||||||||||
Publication Code: | n/a . PackageId = medcom.fhir.dk.xdsmetadata, Canonical = http://medcomfhir.dk/ig/xdsmetadata | ||||||||||||||||||||||||
Realm Check for n/a: |
| ||||||||||||||||||||||||
Language Info: | This IG has no language information | ||||||||||||||||||||||||
Publication Request: |
| ||||||||||||||||||||||||
Supressed Messages: | No Suppressed Issues | ||||||||||||||||||||||||
Dependency Checks: |
| ||||||||||||||||||||||||
Dependent IGs: | no references | ||||||||||||||||||||||||
Global Profiles: | (none declared) | ||||||||||||||||||||||||
Terminology Server(s): | http://tx.fhir.org/r4 (details) | ||||||||||||||||||||||||
HTA Analysis: | Non-HL7 Igs are exempt from terminology dependency analysis | ||||||||||||||||||||||||
R5 Dependencies: | (none) | ||||||||||||||||||||||||
Draft Dependencies: |
| ||||||||||||||||||||||||
Modifier Extensions: | (none) | ||||||||||||||||||||||||
Previous Version Comparison: | Comparison with version 1.0.0 | ||||||||||||||||||||||||
IPA Comparison: | n/a | ||||||||||||||||||||||||
IPS Comparison: | n/a | ||||||||||||||||||||||||
Validation Flags: | On: autoLoad; Off: hintAboutNonMustSupport, anyExtensionsAllowed, checkAggregation, showReferenceMessages, noExperimentalContent, displayWarnings | ||||||||||||||||||||||||
Summary: | errors = 0, warn = 34, info = 0, broken links = 0. |
1 | warning | The HTML fragment 'ip-statements.xhtml' is not included anywhere in the produced implementation guide |
2 | warning | An HTML fragment from the set [cross-version-analysis.xhtml, cross-version-analysis-inline.xhtml] is not included anywhere in the produced implementation guide |
3 | warning | An HTML fragment from the set [dependency-table.xhtml, dependency-table-short.xhtml, dependency-table-nontech.xhtml] is not included anywhere in the produced implementation guide |
4 | warning | The HTML fragment 'globals-table.xhtml' is not included anywhere in the produced implementation guide |
✓ |
✓ |
✓ |
✓ |
✓ |
Path | Severity | Message |
ValueSet.compose.include[0] | warning | Unknown System 'urn:oid:2.16.840.1.113883.6.1' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:2.16.840.1.113883.6.1' could not be found, so the code cannot be validated) VALUESET_UNC_SYSTEM_WARNING |
ValueSet.where(id = 'MedCom-dk-ihe-plr-typecode-VS') | warning | Error from http://tx.fhir.org/r4: Unable to provide support for code system urn:oid:2.16.840.1.113883.6.1 (from server, see log) |
Path | Severity | Message |
ValueSet.compose.include[0] | warning | Unknown System 'urn:oid:2.16.840.1.113883.6.96' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:2.16.840.1.113883.6.96' could not be found, so the code cannot be validated) VALUESET_UNC_SYSTEM_WARNING |
ValueSet.where(id = 'MedCom-ihe-core-HealthcareFacilityTypeCode-VS') | warning | Error from http://tx.fhir.org/r4: Unable to provide support for code system urn:oid:2.16.840.1.113883.6.96 (from server, see log) |
Path | Severity | Message |
ValueSet.compose.include[0] | warning | Unknown System 'urn:oid:2.16.840.1.113883.6.96' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:2.16.840.1.113883.6.96' could not be found, so the code cannot be validated) VALUESET_UNC_SYSTEM_WARNING |
ValueSet.where(id = 'MedCom-ihe-core-PracticeSettingCode-VS') | warning | Error from http://tx.fhir.org/r4: Unable to provide support for code system urn:oid:2.16.840.1.113883.6.96 (from server, see log) |
Path | Severity | Message |
ValueSet.compose.include[0] | warning | Unknown System 'urn:oid:1.2.208.184.100.9' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:1.2.208.184.100.9' could not be found, so the code cannot be validated) VALUESET_UNC_SYSTEM_WARNING |
ValueSet.where(id = 'MedCom-ihe-core-classcode-VS') | warning | Error from http://tx.fhir.org/r4: Unable to provide support for code system urn:oid:1.2.208.184.100.9 (from server, see log) |
Path | Severity | Message |
ValueSet.compose.include[0] | warning | Unknown System 'urn:oid:2.16.840.1.113883.5.25' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:2.16.840.1.113883.5.25' could not be found, so the code cannot be validated) VALUESET_UNC_SYSTEM_WARNING |
ValueSet.where(id = 'MedCom-ihe-core-confidentialitycode-VS') | warning | Error from http://tx.fhir.org/r4: Unable to provide support for code system urn:oid:2.16.840.1.113883.5.25 (from server, see log) |
Path | Severity | Message |
ValueSet.compose.include[0] | warning | Unknown System 'urn:oid:1.2.208.176.2.4' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:1.2.208.176.2.4' could not be found, so the code cannot be validated) VALUESET_UNC_SYSTEM_WARNING |
ValueSet.compose.include[1] | warning | Unknown System 'urn:oid:1.2.208.176.7.3.1' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:1.2.208.176.7.3.1' could not be found, so the code cannot be validated) VALUESET_UNC_SYSTEM_WARNING |
ValueSet.compose.include[2] | warning | Unknown System 'urn:oid:1.2.208.176.2.1' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:1.2.208.176.2.1' could not be found, so the code cannot be validated) VALUESET_UNC_SYSTEM_WARNING |
ValueSet.compose.include[3] | warning | Unknown System 'urn:oid:1.2.208.184.100.1' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:1.2.208.184.100.1' could not be found, so the code cannot be validated) VALUESET_UNC_SYSTEM_WARNING |
ValueSet.compose.include[4] | warning | Unknown System 'urn:ad:dk:medcom:noah:action-categories' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:ad:dk:medcom:noah:action-categories' could not be found, so the code cannot be validated) VALUESET_UNC_SYSTEM_WARNING |
ValueSet.where(id = 'MedCom-ihe-core-eventcodelist-VS') | warning | Error from http://tx.fhir.org/r4: Unable to provide support for code system urn:oid:1.2.208.176.2.4 (from server, see log) |
✓ |
Path | Severity | Message |
ValueSet.compose.include[0] | warning | Unknown System 'urn:oid:1.2.208.176.8.1' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:1.2.208.176.8.1' could not be found, so the code cannot be validated) VALUESET_UNC_SYSTEM_WARNING |
ValueSet.compose.include[1] | warning | Unknown System 'urn:oid:1.2.208.193.100' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:1.2.208.193.100' could not be found, so the code cannot be validated) VALUESET_UNC_SYSTEM_WARNING |
ValueSet (l1/c1892) | warning | Published value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present |
ValueSet.where(id = 'MedCom-ihe-core-homeCommunityId-VS') | warning | Error from http://tx.fhir.org/r4: Unable to provide support for code system urn:oid:1.2.208.176.8.1 (from server, see log) |
Path | Severity | Message |
ValueSet.compose.include[0] | warning | Unknown System 'urn:oid:2.16.840.1.113883.6.121' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:2.16.840.1.113883.6.121' could not be found, so the code cannot be validated) VALUESET_UNC_SYSTEM_WARNING |
ValueSet.where(id = 'MedCom-ihe-core-languagecode-VS') | warning | Error from http://tx.fhir.org/r4: Unable to provide support for code system urn:oid:2.16.840.1.113883.6.121 (from server, see log) |
Path | Severity | Message |
ValueSet.compose.include[0] | warning | Unknown System 'urn:oid:2.16.840.1.113883.5.79' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:2.16.840.1.113883.5.79' could not be found, so the code cannot be validated) VALUESET_UNC_SYSTEM_WARNING |
ValueSet.where(id = 'MedCom-ihe-core-mimetype-VS') | warning | Error from http://tx.fhir.org/r4: Unable to provide support for code system urn:oid:2.16.840.1.113883.5.79 (from server, see log) |
Path | Severity | Message |
ValueSet.compose.include[0] | warning | Unknown System 'urn:oid:2.16.840.1.113883.6.1' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:2.16.840.1.113883.6.1' could not be found, so the code cannot be validated) VALUESET_UNC_SYSTEM_WARNING |
ValueSet.compose.include[1] | warning | Unknown System 'urn:oid:1.2.208.184.100.1' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:1.2.208.184.100.1' could not be found, so the code cannot be validated) VALUESET_UNC_SYSTEM_WARNING |
ValueSet.where(id = 'MedCom-ihe-core-typecode-VS') | warning | Error from http://tx.fhir.org/r4: Unable to provide support for code system urn:oid:2.16.840.1.113883.6.1 (from server, see log) |
Path | Severity | Message |
ValueSet.compose.include[0] | warning | Unknown System 'urn:oid:1.2.208.184.100.10' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:1.2.208.184.100.10' could not be found, so the code cannot be validated) VALUESET_UNC_SYSTEM_WARNING |
ValueSet (l1/c1255) | warning | Published value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present |
ValueSet.where(id = 'MedCom-ihe-plr-formatcode-VS') | warning | Error from http://tx.fhir.org/r4: Unable to provide support for code system urn:oid:1.2.208.184.100.10 (from server, see log) |
Suppressed Messages (Warnings, hints, broken links)
No suppressed messsages
Errors sorted by type
fsh-generated/resources/ValueSet-MedCom-dk-ihe-plr-typecode-VS.json | Unknown System 'urn:oid:2.16.840.1.113883.6.1' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:2.16.840.1.113883.6.1' could not be found, so the code cannot be validated) |
fsh-generated/resources/ValueSet-MedCom-ihe-core-HealthcareFacilityTypeCode-VS.json | Unknown System 'urn:oid:2.16.840.1.113883.6.96' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:2.16.840.1.113883.6.96' could not be found, so the code cannot be validated) |
fsh-generated/resources/ValueSet-MedCom-ihe-core-PracticeSettingCode-VS.json | Unknown System 'urn:oid:2.16.840.1.113883.6.96' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:2.16.840.1.113883.6.96' could not be found, so the code cannot be validated) |
fsh-generated/resources/ValueSet-MedCom-ihe-core-classcode-VS.json | Unknown System 'urn:oid:1.2.208.184.100.9' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:1.2.208.184.100.9' could not be found, so the code cannot be validated) |
fsh-generated/resources/ValueSet-MedCom-ihe-core-confidentialitycode-VS.json | Unknown System 'urn:oid:2.16.840.1.113883.5.25' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:2.16.840.1.113883.5.25' could not be found, so the code cannot be validated) |
fsh-generated/resources/ValueSet-MedCom-ihe-core-eventcodelist-VS.json | Unknown System 'urn:oid:1.2.208.176.2.4' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:1.2.208.176.2.4' could not be found, so the code cannot be validated) |
fsh-generated/resources/ValueSet-MedCom-ihe-core-eventcodelist-VS.json | Unknown System 'urn:oid:1.2.208.176.7.3.1' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:1.2.208.176.7.3.1' could not be found, so the code cannot be validated) |
fsh-generated/resources/ValueSet-MedCom-ihe-core-eventcodelist-VS.json | Unknown System 'urn:oid:1.2.208.176.2.1' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:1.2.208.176.2.1' could not be found, so the code cannot be validated) |
fsh-generated/resources/ValueSet-MedCom-ihe-core-eventcodelist-VS.json | Unknown System 'urn:oid:1.2.208.184.100.1' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:1.2.208.184.100.1' could not be found, so the code cannot be validated) |
fsh-generated/resources/ValueSet-MedCom-ihe-core-eventcodelist-VS.json | Unknown System 'urn:ad:dk:medcom:noah:action-categories' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:ad:dk:medcom:noah:action-categories' could not be found, so the code cannot be validated) |
fsh-generated/resources/ValueSet-MedCom-ihe-core-homeCommunityId-VS.json | Unknown System 'urn:oid:1.2.208.176.8.1' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:1.2.208.176.8.1' could not be found, so the code cannot be validated) |
fsh-generated/resources/ValueSet-MedCom-ihe-core-homeCommunityId-VS.json | Unknown System 'urn:oid:1.2.208.193.100' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:1.2.208.193.100' could not be found, so the code cannot be validated) |
fsh-generated/resources/ValueSet-MedCom-ihe-core-languagecode-VS.json | Unknown System 'urn:oid:2.16.840.1.113883.6.121' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:2.16.840.1.113883.6.121' could not be found, so the code cannot be validated) |
fsh-generated/resources/ValueSet-MedCom-ihe-core-mimetype-VS.json | Unknown System 'urn:oid:2.16.840.1.113883.5.79' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:2.16.840.1.113883.5.79' could not be found, so the code cannot be validated) |
fsh-generated/resources/ValueSet-MedCom-ihe-core-typecode-VS.json | Unknown System 'urn:oid:2.16.840.1.113883.6.1' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:2.16.840.1.113883.6.1' could not be found, so the code cannot be validated) |
fsh-generated/resources/ValueSet-MedCom-ihe-core-typecode-VS.json | Unknown System 'urn:oid:1.2.208.184.100.1' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:1.2.208.184.100.1' could not be found, so the code cannot be validated) |
fsh-generated/resources/ValueSet-MedCom-ihe-plr-formatcode-VS.json | Unknown System 'urn:oid:1.2.208.184.100.10' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'urn:oid:1.2.208.184.100.10' could not be found, so the code cannot be validated) |