Quality Checks |
Publisher Version: | IG Publisher Version: v1.7.1 |
Publication Code: | n/a . PackageId = medcom.fhir.dk.ihe.xds.metadata, Canonical = https://medcomfhir.dk/ig/ihexdsmetadata |
Realm Check for n/a: | |
Publication Request: | - This IG has never been published
- This IG has never been published, so the version should start with '0.' or include a patch version e.g. '-ballot'
- No publication request found
|
Supressed Messages: | No Suppressed Issues
|
Dependency Checks: | Package | Version | FHIR | Canonical | Web Base | Comment |
---|
medcom.fhir.dk.ihe.xds.metadata | 1.0.0 | R4 | https://medcomfhir.dk/ig/ihexdsmetadata | | |
hl7.terminology.r4 | 6.0.2 M | R4 | http://terminology.hl7.org | http://terminology.hl7.org/6.0.2 | |
hl7.fhir.uv.extensions.r4 | 5.1.0 M | R4 | http://hl7.org/fhir/extensions | http://hl7.org/fhir/extensions/5.1.0 | |
medcom.fhir.dk.core | 2.1.0 O | R4 | http://medcomfhir.dk/ig/core | http://medcomfhir.dk/ig/core/2.1.0 | Latest Release is 2.3.0 |
hl7.terminology.r4 | 5.0.0 O | R4 | http://terminology.hl7.org | http://terminology.hl7.org/5.0.0 | Latest Release is 6.0.2 |
hl7.fhir.dk.core | 2.0.0 O | R4 | http://hl7.dk/fhir/core | http://hl7.dk/fhir/core/2.0.0 | Latest Release is 3.2.0 |
hl7.terminology.r4 | 3.1.0 O | R4 | http://terminology.hl7.org | http://terminology.hl7.org/3.1.0 | Latest Release is 6.0.2 |
medcom.fhir.dk.terminology | 1.1.0 O | R4 | http://medcomfhir.dk/ig/terminology | http://medcomfhir.dk/ig/terminology/1.1.0 | Latest Release is 1.1.1 |
hl7.terminology.r4 | 5.0.0 O | R4 | http://terminology.hl7.org | http://terminology.hl7.org/5.0.0 | see above. Latest Release is 6.0.2 |
hl7.fhir.dk.core | 2.2.0 O | R4 | http://hl7.dk/fhir/core | http://hl7.dk/fhir/core/2.2.0 | Latest Release is 3.2.0 |
hl7.terminology.r4 | 5.0.0 O | R4 | http://terminology.hl7.org | http://terminology.hl7.org/5.0.0 | see above. Latest Release is 6.0.2 |
hl7.fhir.uv.phd | 1.0.0 O | R4 | http://hl7.org/fhir/uv/phd | http://hl7.org/fhir/uv/phd/STU1 | Latest Release is 1.1.0 |
hl7.terminology.r4 | 3.1.0 O | R4 | http://terminology.hl7.org | http://terminology.hl7.org/3.1.0 | see above. Latest Release is 6.0.2 |
Templates: medcom.dk.fhir.template#0.0.1 -> fhir.base.template#current. Tools: 0.2.0 |
Dependent IGs: | no references |
Global Profiles: | (none declared) |
Terminology Server(s): | http://tx.fhir.org/r4 (details) |
HTA Analysis: | Non-HL7 Igs are exempt from terminology dependency analysis |
R5 Dependencies: | (none) |
Draft Dependencies: |
-
hl7.fhir.r4.core#4.0.1: GuideParameterCode
(15 uses), CompositionAttestationMode
(4 uses), CommonLanguages
(10 uses), Organization
(22 uses), DocumentReferenceStatus
(5 uses), CompositionStatus
(5 uses), DocumentRelationshipType
(5 uses), DocumentReference
(6 uses), Encounter
(5 uses), EpisodeOfCare
(5 uses), ContactEntityType
(1 uses), Endpoint
(1 uses), Practitioner
(2 uses), PractitionerRole
(2 uses), RelatedPerson
(1 uses)
-
hl7.fhir.uv.tools#0.2.0: ResourceSortExt
(17 uses)
|
Modifier Extensions: | (none) |
Previous Version Comparison: | Unable to compare with previous version: Unable to find version history at https://medcomfhir.dk/ig/ihexdsmetadata (Problem #1 with package-list.json at https://medcomfhir.dk/ig/ihexdsmetadata: Not Found) |
IPA Comparison: | n/a |
IPS Comparison: | n/a |
Validation Flags: | On: autoLoad; Off: hintAboutNonMustSupport, anyExtensionsAllowed, checkAggregation, showReferenceMessages, noExperimentalContent, displayWarnings |
Summary: | errors = 0, warn = 74, info = 15, broken links = 4 |
Path | Severity | Message |
DocumentReference.extension[0].value.ofType(Coding) (l142/c8) | information | A definition for CodeSystem 'urn:oid:1.2.208.176.8.1' could not be found, so the code cannot be validated |
DocumentReference.extension[0].value.ofType(Coding) (l142/c8) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-ihe-qrd-homeCommunityId-VS' not found |
DocumentReference.type.coding[0].system (l163/c4) | warning | A definition for CodeSystem 'urn:oid:2.16.840.1.113883.6.1' could not be found, so the code cannot be validated (from http://tx.fhir.org/r4) |
DocumentReference.type.coding[0] (l165/c8) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-dk-ihe-qrd-typecode-VS' not found |
DocumentReference.type.coding[0] (l165/c8) | information | A definition for CodeSystem 'urn:oid:2.16.840.1.113883.6.1' could not be found, so the code cannot be validated |
DocumentReference.category[0] (l75/c6) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-ihe-core-classcode-VS' not found |
DocumentReference.category[0].coding[0].system (l75/c6) | warning | A definition for CodeSystem 'urn:oid:1.2.208.184.100.9' could not be found, so the code cannot be validated (from http://tx.fhir.org/r4) |
DocumentReference.securityLabel[0].coding[0] (l154/c6) | warning | Coding has no system. A code with no system has no defined meaning, and it cannot be validated. A system should be provided (from http://tx.fhir.org/r4, see log) |
DocumentReference.content[0].attachment.contentType (l93/c34) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-ihe-mimeType-VS' not found |
DocumentReference.content[0].attachment.language (l94/c25) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-ihe-core-languagecode-VS' not found |
DocumentReference.content[0].format (l101/c8) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-ihe-qrd-formatcode-VS' not found |
DocumentReference.content[0].format (l101/c8) | information | A definition for CodeSystem 'urn:oid:1.2.208.184.100.10' could not be found, so the code cannot be validated |
DocumentReference.context.event[0] (l110/c8) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-dk-ihe-qrd-eventcodelist-VS' not found |
DocumentReference.context.event[0].coding[0].system (l110/c8) | warning | A definition for CodeSystem 'urn:oid:1.2.208.176.2.4' could not be found, so the code cannot be validated (from http://tx.fhir.org/r4) |
DocumentReference.context.facilityType.coding[0].system (l120/c6) | warning | A definition for CodeSystem 'urn:oid:2.16.840.1.113883.6.96' could not be found, so the code cannot be validated (from http://tx.fhir.org/r4) |
DocumentReference.context.facilityType.coding[0].system (l124/c53) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-ihe-core-HealthcareFacilityTypeCode-VS' not found |
DocumentReference.context.practiceSetting.coding[0] (l129/c6) | warning | A definition for CodeSystem 'urn:oid:2.16.840.1.113883.6.96' could not be found, so the code cannot be validated |
DocumentReference.context.practiceSetting.coding[0].system (l133/c53) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-ihe-core-PracticeSettingCode-VS' not found |
Path | Severity | Message |
DocumentReference.extension[0].value.ofType(Coding) (l142/c8) | information | A definition for CodeSystem 'urn:oid:1.2.208.176.8.1' could not be found, so the code cannot be validated |
DocumentReference.extension[0].value.ofType(Coding) (l142/c8) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-ihe-phad-homeCommunityId-VS' not found |
DocumentReference.type (l163/c4) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-dk-ihe-phad-typecode-VS' not found |
DocumentReference.type.coding[0] (l163/c4) | warning | A definition for CodeSystem 'urn:oid:2.16.840.1.113883.6.1' could not be found, so the code cannot be validated |
DocumentReference.category[0] (l75/c6) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-ihe-core-classcode-VS' not found |
DocumentReference.category[0].coding[0].system (l75/c6) | warning | A definition for CodeSystem 'urn:oid:1.2.208.184.100.9' could not be found, so the code cannot be validated (from http://tx.fhir.org/r4) |
DocumentReference.securityLabel[0].coding[0] (l154/c6) | warning | Coding has no system. A code with no system has no defined meaning, and it cannot be validated. A system should be provided (from http://tx.fhir.org/r4, see log) |
DocumentReference.content[0].attachment.contentType (l93/c34) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-ihe-mimeType-VS' not found |
DocumentReference.content[0].attachment.language (l94/c25) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-ihe-core-languagecode-VS' not found |
DocumentReference.content[0].format (l101/c8) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-ihe-phad-formatcode-VS' not found |
DocumentReference.content[0].format (l101/c8) | information | A definition for CodeSystem 'urn:oid:1.2.208.184.100.10' could not be found, so the code cannot be validated |
DocumentReference.context.event[0] (l110/c8) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-dk-ihe-phad-eventcodelist-VS' not found |
DocumentReference.context.event[0].coding[0].system (l110/c8) | warning | A definition for CodeSystem 'urn:oid:1.2.208.176.2.4' could not be found, so the code cannot be validated (from http://tx.fhir.org/r4) |
DocumentReference.context.facilityType.coding[0].system (l120/c6) | warning | A definition for CodeSystem 'urn:oid:2.16.840.1.113883.6.96' could not be found, so the code cannot be validated (from http://tx.fhir.org/r4) |
DocumentReference.context.facilityType.coding[0].system (l124/c53) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-ihe-core-HealthcareFacilityTypeCode-VS' not found |
DocumentReference.context.practiceSetting.coding[0] (l129/c6) | warning | A definition for CodeSystem 'urn:oid:2.16.840.1.113883.6.96' could not be found, so the code cannot be validated |
DocumentReference.context.practiceSetting.coding[0].system (l133/c53) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-ihe-core-PracticeSettingCode-VS' not found |
Path | Severity | Message |
DocumentReference.extension[0].value.ofType(Coding) (l142/c8) | information | A definition for CodeSystem 'urn:oid:1.2.208.176.8.1' could not be found, so the code cannot be validated |
DocumentReference.extension[0].value.ofType(Coding) (l142/c8) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-ihe-hco-homeCommunityId-VS' not found |
DocumentReference.type (l163/c4) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-dk-ihe-hco-typecode-VS' not found |
DocumentReference.type.coding[0] (l163/c4) | warning | A definition for CodeSystem 'urn:oid:2.16.840.1.113883.6.1' could not be found, so the code cannot be validated |
DocumentReference.category[0] (l75/c6) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-ihe-core-classcode-VS' not found |
DocumentReference.category[0].coding[0].system (l75/c6) | warning | A definition for CodeSystem 'urn:oid:1.2.208.184.100.9' could not be found, so the code cannot be validated (from http://tx.fhir.org/r4) |
DocumentReference.securityLabel[0].coding[0] (l154/c6) | warning | Coding has no system. A code with no system has no defined meaning, and it cannot be validated. A system should be provided (from http://tx.fhir.org/r4, see log) |
DocumentReference.content[0].attachment.contentType (l93/c34) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-ihe-mimeType-VS' not found |
DocumentReference.content[0].attachment.language (l94/c25) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-ihe-core-languagecode-VS' not found |
DocumentReference.content[0].format (l101/c8) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-ihe-hco-formatcode-VS' not found |
DocumentReference.content[0].format (l101/c8) | information | A definition for CodeSystem 'urn:oid:1.2.208.184.100.10' could not be found, so the code cannot be validated |
DocumentReference.context.event[0] (l110/c8) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-dk-ihe-hco-eventcodelist-VS' not found |
DocumentReference.context.event[0].coding[0] (l110/c8) | warning | A definition for CodeSystem 'urn:oid:1.2.208.176.2.4' could not be found, so the code cannot be validated |
DocumentReference.context.facilityType.coding[0] (l120/c6) | warning | A definition for CodeSystem 'urn:oid:2.16.840.1.113883.6.96' could not be found, so the code cannot be validated |
DocumentReference.context.facilityType.coding[0].system (l124/c53) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-ihe-core-HealthcareFacilityTypeCode-VS' not found |
DocumentReference.context.practiceSetting.coding[0] (l129/c6) | warning | A definition for CodeSystem 'urn:oid:2.16.840.1.113883.6.96' could not be found, so the code cannot be validated |
DocumentReference.context.practiceSetting.coding[0].system (l133/c53) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-ihe-core-PracticeSettingCode-VS' not found |
Path | Severity | Message |
DocumentReference.extension[0].value.ofType(Coding) (l142/c8) | information | A definition for CodeSystem 'urn:oid:1.2.208.176.8.1' could not be found, so the code cannot be validated |
DocumentReference.extension[0].value.ofType(Coding) (l142/c8) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-ihe-apd-homeCommunityId-VS' not found |
DocumentReference.type (l163/c4) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-dk-ihe-apd-typecode-VS' not found |
DocumentReference.type.coding[0] (l163/c4) | warning | A definition for CodeSystem 'urn:oid:2.16.840.1.113883.6.1' could not be found, so the code cannot be validated |
DocumentReference.category[0] (l75/c6) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-ihe-core-classcode-VS' not found |
DocumentReference.category[0].coding[0].system (l75/c6) | warning | A definition for CodeSystem 'urn:oid:1.2.208.184.100.9' could not be found, so the code cannot be validated (from http://tx.fhir.org/r4) |
DocumentReference.securityLabel[0].coding[0] (l154/c6) | warning | Coding has no system. A code with no system has no defined meaning, and it cannot be validated. A system should be provided (from http://tx.fhir.org/r4, see log) |
DocumentReference.content[0].attachment.contentType (l93/c34) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-ihe-mimeType-VS' not found |
DocumentReference.content[0].attachment.language (l94/c25) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-ihe-core-languagecode-VS' not found |
DocumentReference.content[0].format (l101/c8) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-ihe-apd-formatcode-VS' not found |
DocumentReference.content[0].format (l101/c8) | information | A definition for CodeSystem 'urn:oid:1.2.208.184.100.10' could not be found, so the code cannot be validated |
DocumentReference.context.event[0] (l110/c8) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-dk-ihe-apd-eventcodelist-VS' not found |
DocumentReference.context.event[0].coding[0].system (l110/c8) | warning | A definition for CodeSystem 'urn:oid:1.2.208.176.2.4' could not be found, so the code cannot be validated (from http://tx.fhir.org/r4) |
DocumentReference.context.facilityType.coding[0].system (l120/c6) | warning | A definition for CodeSystem 'urn:oid:2.16.840.1.113883.6.96' could not be found, so the code cannot be validated (from http://tx.fhir.org/r4) |
DocumentReference.context.facilityType.coding[0].system (l124/c53) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-ihe-core-HealthcareFacilityTypeCode-VS' not found |
DocumentReference.context.practiceSetting.coding[0] (l129/c6) | warning | A definition for CodeSystem 'urn:oid:2.16.840.1.113883.6.96' could not be found, so the code cannot be validated |
DocumentReference.context.practiceSetting.coding[0].system (l133/c53) | warning | ValueSet 'http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-ihe-core-PracticeSettingCode-VS' not found |
Path | Severity | Message |
CoreDocumentReference.DocumentReference.content.attachment.contentType | warning | Binding http://medcomfhir.dk/ig/xdsmetadata/ValueSet/MedCom-ihe-mimeType-VS could not be located |
StructureDefinition.snapshot.element[59].pattern.ofType(CodeableConcept).coding[0] (l1/c182515) | warning | Coding has no system. A code with no system has no defined meaning, and it cannot be validated. A system should be provided |
StructureDefinition.differential.element[16].pattern.ofType(CodeableConcept).coding[0] (l1/c268851) | warning | Coding has no system. A code with no system has no defined meaning, and it cannot be validated. A system should be provided |
StructureDefinition.snapshot.element[59].pattern.ofType(CodeableConcept) | information | The repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users) |
StructureDefinition.where(url = 'https://medcomfhir.dk/ig/ihexdsmetadata/StructureDefinition/core-documentreference') | warning | The Implementation Guide contains no examples for this profile |