Medication IG DE
2.0.0-ballot - ballot

Medication IG DE, published by HL7 Deutschland e.V.. This guide is not an authorized publication; it is the continuous build for version 2.0.0-ballot built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7germany/medication-ig-de-r4/ and changes regularly. See the Directory of published versions

Resource Profile: MedicationStatementDE - Examples

Active as of 2026-10-16

Examples for the MedicationStatementDE Profile.

Invalid: dos-1 (asNeededFor with asNeeded=false)
Warning (Statement): asNeededFor without asNeeded
Warning (Statement): mixed dose units
Warning (Statement): negative doseRange.high.value
Warning (Statement): Mindestabstand = 0 h
Warning (Statement): maxDosePerPeriod.numerator = 0
Warning (Statement): maxDosePerPeriod.denominator = -24 h
Warning (Statement): text and structured dosage
Warning (Statement): timing without dose
Warning (Statement): multiple free text dosages
Warning (Statement): boundsDuration unit/code mismatch
Warning: frequency and period both greater than one
Warning: variable frequency combined with variable period
Warning (Statement): split timeOfDay into two dosages (same dose)
Warning (Statement): teilweise identische Dosis bei timeOfDay
Warning (Statement): split when into two dosages (same dose)
Warning (Statement): teilweise identische Dosis bei when
Warning (Statement): period = 0
Warning (Statement): boundsDuration = 0 d
Warning (Statement): boundsRange.low = -1
Warning (Statement): periodMax = -2
Warning (Statement): boundsRange.high = -1