Danish Implementation Guide for SMART App Launch
1.0.0 - trial-use
Danish Implementation Guide for SMART App Launch, published by HL7 Denmark. This guide is not an authorized publication; it is the continuous build for version 1.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7dk/dk-smart/ and changes regularly. See the Directory of published versions
Official URL: http://hl7.dk/fhir/smart/ImplementationGuide/hl7.fhir.dk.smart | Version: 1.0.0 | |||
Active as of 2024-11-27 | Computable Name: DKSmart |
THESE ARE VERY EARLY DRAFTS THIS IS NOT AN AUTHORIZED PUBLICATION
This is the Danish implementation guide for the SMART App Launch mechanism.
This is an R4 IG. None of the features it uses are changed in R4B, so it can be used as is with R4B systems. Packages for both R4 (hl7.fhir.dk.smart.r4) and R4B (hl7.fhir.dk.smart.r4b) are available.
It builds on top of both the HL7 SMART App Launch and the HL7 International Patient Access specifications.
IG | Package | FHIR | Comment |
---|---|---|---|
Danish Implementation Guide for SMART App Launch | hl7.fhir.dk.smart#1.0.0 | R4 | |
HL7 Terminology (THO) | hl7.terminology.r4#6.1.0 | R4 | Automatically added as a dependency - all IGs depend on HL7 Terminology |
FHIR Extensions Pack | hl7.fhir.uv.extensions.r4#5.1.0 | R4 | Automatically added as a dependency - all IGs depend on the HL7 Extension Pack |
International Patient Access | hl7.fhir.uv.ipa#1.0.0 | R4 | |
SMART App Launch | hl7.fhir.uv.smart-app-launch#2.2.0 | R4 |
SMART App Launch is the mechanism through which third-party apps can be integrated with Electronic Health Record (EHR) systems. It specifies how apps gain knowledge of which practitioner or patient wants to access which patient's information, and how the app obtains the access token that can then be used to access further information.
You can think of it as a single-sign-on (SSO) mechanism, but it is actually a bit more and extends to communicating the context too.
When launched, the third party apps can either stand on their own or be embedded into the views of the EHR or a patient portal.
The SMART specification is suitable for both web based apps and native apps. It makes a distinction between public and confidential apps.
In addition to launching apps, the main SMART specification defines a profile for backend services.
There is a separate implementation guide for Danish Core Profiles that defines the Danish Core profiles for some of the key FHIR resources.
The SMART App Launch specification is already a globally applicable specification. The International Patient Access (IPA) specification adds some more constraints and details to it. Do we really need something more?
We have found out that there are still some places in both of these specifications that allow some implementation freedom but may be tricky for app developers to support. In this implementation guide, we aim to provide clarity on topics like how an app best learns the organization or organization unit the practitioner launching the app works for (when launching the app).
We believe we can get some of these details sorted out more efficiently in the local Danish context. We still aim to feed our learnings and developments with the wider SMART community and help get parts of them adopted to the SMART and IPA specifications.
Okay, a simplified take on it is like this:
So, when we pair DK Core (with the danish models) and DK SMART (which outlines standardised access) we end up with a standardised way of expressing the data model and the data access which is the core essense of bridging systems and break down silos. This inherently supports initiatives like https://medcom.dk/projekter/apps-i-almen-praksis/ and boards like https://laegemiddelstyrelsen.dk/da/udstyr/naevnet-for-sundhedsapps/
National existing solutions like MitID and SEB as well as any local SAML-based solution can be incorporated into using SMART-flows for the authentication/authorization-parts adding value to the entire chain. The use of SMART does not compromise that. It only strengthens is.
See the Finnish progress here
To learn about the current status in Denmark, please contact HL7 Denmark. We're happy to give you an overview.
The base FHIR specification works on a global scope. It is hard to achieve consensus on many things globally. However, smaller regions and jurisdictions are in a better position to agree on tighter constraints. We take benefit of this and move faster with things that we can agree on on a local level.
We are also committed to sharing our learnings with the wider FHIR community and get parts of the definitions adopted in the international main specifications.
We hope that publishing examples gives new implementers a glance of how systems exchange information. However, implementers are strongly encouraged to read the main SMART specification and the relevant parts of the IPA specification. This implementation guide should not be used as a comprehensive specification on which to build implementations.
The profiling work is performed in a project driven by HL7 Denmark. See the announcement and the running european memo. We warmly welcome new participants to the project.
The team involved in creating the first version of the implementation guide includes
Each published major version of this implementation guide goes through the ballot and voting processes of HL7 Denmark.
The following sub sections will list recommendations when using SMART in a Danish setting
It is discouraged to use symmetric authentication (client_secret) for clients that cannot maintain a secret as listed here and hence should be avoided.
Any vendor providing access to data (not limited to, but including using SMART) MUST remember that access to such provided data in many cases are subject to be sent to MinLog.
We want this implementation guide to be useful for you.
If you are implementing SMART App launch in a system or application that is meant to be used in Denmark and are thinking of some implementation details, you are probably in the right place and this implementation guide should help you with those questions. If this implementation guide in any way fails to give you the answers you are looking for, we'd love to hear about it so we can make it better. Please do be in touch in one of the ways listed below.
The source code of this implementation guide is maintained in a publicly accessible repository in GitHub. Issues opened in that GitHub repo are very welcome. They help the team pick up any proposed changes or additions and to discuss them publicly.
Pull requests are even better. If you are in a position to suggest how exactly your proposal should be implemented in the specification, do it! It helps the team maintaining the implementation guide a great deal.
Please also consider joining the development effort. This is the best way to affect the outcome of the profiling work. You may even be compensated for your efforts. Please be in touch with HL7 Denmark to discuss options, if this even remotely interesting for you.
The best implementation guide is the one that reflects the views and the consensus of the whole FHIR community!
This implementation guide defines data elements, resources, formats, and methods for exchanging healthcare data between different participants in the healthcare process. As such, clinical safety is a key concern. Additional guidance regarding safety for the specification’s many and various implementations is available at https://www.hl7.org/FHIR/safety.html.
Although the present specification does give users the opportunity to observe data protection and data security regulations, its use does not guarantee compliance with these regulations. Effective compliance must be ensured by appropriate measures during implementation projects and in daily operations. The corresponding implementation measures are explained in the standard. In addition, the present specification can only influence compliance with the security regulations in the technical area of standardisation. It cannot influence organisational and contractual matters.
This document is licensed under Creative Commons CC0 1.0 Universal Public Domain Dedication.
This implementation guide contains and references intellectual property owned by third parties ("Third Party IP"). Acceptance of these License Terms does not grant any rights with respect to Third Party IP. The licensee alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize Third Party IP in connection with the specification or otherwise.
HL7®, HEALTH LEVEL SEVEN®, FHIR® and the FHIR ® are trademarks owned by Health Level Seven International, registered with the United States Patent and Trademark Office.
See also http://hl7.org/fhir/license.html.
This publication includes IP covered under the following statements.