Quality Checks |
Publisher Version: | IG Publisher Version: v1.7.1 |
Publication Code: | n/a . PackageId = hl7.fhir.dk.core, Canonical = http://hl7.dk/fhir/core |
Realm Check for n/a: | |
Publication Request: |
package-id | hl7.fhir.dk.core |
version | 3.3.0 |
path | http://hl7.dk/fhir/core/3.3.0 |
Pub-Mode | milestone |
status | release |
Release-Label | ci-build |
sequence | Release |
desc | DK Core version 3.3.0 |
descmd | Dk-core version 3.3.0 has been approved by HL7 Denmark.
The changes between 3.2.0 and 3.3.0 are:
- Minor linguistic adjustments
- Introduced the use of IPA profiles as base profiles where it makes sense.
- Refined NPU Fragment Code System
|
- Publication request category found (not allowed after first publication
- Publication request title found (not allowed after first publication)
- Publication request introduction found (not allowed after first publication)
- Publication request ci-build found (not allowed after first publication)
|
Supressed Messages: | 24 Suppressed Issues
|
Dependency Checks: | Package | Version | FHIR | Canonical | Web Base | Comment |
---|
hl7.fhir.dk.core | 3.3.0 | R4 | http://hl7.dk/fhir/core | | |
hl7.terminology.r4 | 6.0.2 M | R4 | http://terminology.hl7.org | http://terminology.hl7.org/6.0.2 | |
hl7.fhir.uv.extensions.r4 | 5.1.0 M | R4 | http://hl7.org/fhir/extensions | http://hl7.org/fhir/extensions/5.1.0 | |
hl7.fhir.uv.phd | 1.0.0 O | R4 | http://hl7.org/fhir/uv/phd | http://hl7.org/fhir/uv/phd/STU1 | Latest Release is 1.1.0 |
hl7.terminology.r4 | 3.1.0 O | R4 | http://terminology.hl7.org | http://terminology.hl7.org/3.1.0 | Latest Release is 6.0.2 |
hl7.fhir.uv.ipa | 1.0.0 M | R4 | http://hl7.org/fhir/uv/ipa | http://hl7.org/fhir/uv/ipa/STU1 | |
hl7.terminology.r4 | 5.0.0 O | R4 | http://terminology.hl7.org | http://terminology.hl7.org/5.0.0 | Latest Release is 6.0.2 |
hl7.fhir.uv.smart-app-launch | 2.0.0 O | R4 | http://hl7.org/fhir/smart-app-launch | http://hl7.org/fhir/smart-app-launch/STU2 | Latest Release is 2.2.0 |
Templates: hl7.dk.fhir.template#0.0.1 -> fhir.base.template#current. Tools: 0.2.0 |
Dependent IGs: | 15 guides |
Global Profiles: | (none declared) |
Terminology Server(s): | http://tx.fhir.org/r4 (details) |
HTA Analysis: | 6 issues |
R5 Dependencies: | |
Draft Dependencies: |
-
hl7.fhir.r4.core#4.0.1: GuideParameterCode
(15 uses), observation-vitalsigns
(4 uses), observation-bp
(1 uses), observation-heartrate
(2 uses), CareTeamStatus
(1 uses), ConsentState
(1 uses), FHIR Defined Concept Properties
(4 uses), EpisodeOfCareStatus
(1 uses), RequestStatus
(1 uses), observation-bodyweight
(1 uses), CommonLanguages
(14 uses), CarePlan
(4 uses), DeviceRequest
(3 uses), ImmunizationRecommendation
(3 uses), MedicationRequest
(4 uses), NutritionOrder
(3 uses), ServiceRequest
(7 uses), MedicationAdministration
(3 uses), MedicationDispense
(3 uses), MedicationStatement
(3 uses), Procedure
(3 uses), Immunization
(3 uses), ImagingStudy
(6 uses), ObservationCategoryCodes
(3 uses), LOINCCodes
(6 uses), Encounter
(5 uses), CareTeam
(6 uses), SNOMEDCTBodyStructures
(5 uses), ObservationMethods
(3 uses), Specimen
(4 uses), Device
(10 uses), DeviceMetric
(3 uses), ObservationReferenceRangeMeaningCodes
(3 uses), ObservationReferenceRangeAppliesToCodes
(3 uses), QuestionnaireResponse
(6 uses), MolecularSequence
(6 uses), DocumentReference
(5 uses), Media
(3 uses), Organization
(25 uses), Group
(3 uses), Condition
(5 uses), ConditionClinicalStatusCodes
(1 uses), ConditionVerificationStatus
(1 uses), ConditionCategoryCodes
(1 uses), Condition/DiagnosisSeverity
(1 uses), Condition/Problem/DiagnosisCodes
(3 uses), ConditionStage
(1 uses), ClinicalImpression
(1 uses), DiagnosticReport
(3 uses), ConditionStageType
(1 uses), ManifestationAndSymptomCodes
(1 uses), Location
(2 uses), LocationStatus
(1 uses), LocationMode
(1 uses), LocationType
(1 uses), Endpoint
(3 uses), ContactEntityType
(1 uses), Practitioner
(1 uses), PractitionerRole
(5 uses), ActivityDefinition
(1 uses), PlanDefinition
(1 uses), RequestStatus
(1 uses), RequestIntent
(1 uses), ProcedureCodes(SNOMEDCT)
(1 uses), ServiceRequestOrderDetailsCodes
(1 uses), SNOMEDCTMedicationAsNeededReasonCodes
(1 uses), ParticipantRoles
(1 uses), HealthcareService
(3 uses), ProcedureReasonCodes
(1 uses), Coverage
(1 uses), ClaimResponse
(1 uses), Provenance
(1 uses), PractitionerRole
(1 uses), RelatedPerson
(1 uses), RequestPriority
(1 uses), RequestPriority
(1 uses)
-
hl7.fhir.uv.extensions.r4#5.1.0: SDImposeProfile
(1 uses)
-
hl7.fhir.uv.phd#1.0.0: PhdImplementationGuide
(1 uses), PhdPatient
(2 uses), PhgDevice
(2 uses), ContinuaDeviceIdentifiers
(8 uses), ContinuaPHD
(5 uses), ContinuaHFS
(2 uses), ASN1ToHL7
(12 uses), PhdDevice
(3 uses), PhdNumericObservation
(4 uses), PhdCoincidentTimeStampObservation
(2 uses), PhdCompoundNumericObservation
(1 uses), PhdBitsEnumerationObservation
(1 uses)
-
hl7.fhir.uv.tools#0.2.0: ResourceSortExt
(117 uses)
|
Modifier Extensions: | (none) |
Previous Version Comparison: | Comparison with version 3.2.0 |
IPA Comparison: | Comparison with version 1.0.0 |
IPS Comparison: | n/a |
Validation Flags: | On: autoLoad; Off: hintAboutNonMustSupport, anyExtensionsAllowed, checkAggregation, showReferenceMessages, noExperimentalContent, displayWarnings |
Summary: | errors = 0, warn = 103, info = 33, broken links = 3 |
| warning | This IG is version 4.0.1, while the IG 'hl7.fhir.uv.tools' is from version 5.0.0 |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Device/BPMonitor.C4F312FFFE53F2C9. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/CoincidentTimeStamp.0222. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/ElseBloodPressure. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/ElseBodyTemperature. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/ElseConsciousness. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/ElseHeartRate. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/ElseRespirationRate. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/ElseUrinStix. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/ElsesTOBSscore. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/HeartRate.Poul.1974654. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/ObservationOxySatBasicObservationOrg. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/MaxBloodPressure. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/MaxBodyTemperature. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/MaxConsciousness. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/MaxGlasgowComaScale. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/MaxHeartRate. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/MaxRespirationRate. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/MaxSaturation. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/MaxVitalSignsPanel. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Patient/Poul. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Device/Telma.FEEDDADADEADBEEF. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
output/StructureDefinition-dk-core-person-servicerequest-definitions.html#/html/body/div/div/div/div/div/div/div/table/tr/td/p/a at Line 444, column 965 | error | The link 'http://hl7.org/fhir/R4/valueset-diagnostic-requests.html' for "here" cannot be resolved |
output/StructureDefinition-dk-core-person-servicerequest.html#/html/body/div/div/div/div/div/div/div/div/div/table/tr/td/a at Line 728, column 902 | error | The link 'http://hl7.org/fhir/R4/valueset-diagnostic-requests.html' for "here" cannot be resolved |
output/StructureDefinition-dk-core-person-servicerequest.html#/html/body/div/div/div/div/div/div/div/div/div/table/tr/td/a at Line 1751, column 902 | error | The link 'http://hl7.org/fhir/R4/valueset-diagnostic-requests.html' for "here" cannot be resolved |
Path | Severity | Message |
Bundle.entry[0].resource/*Patient/Poul*/.name[0] (l37/c12) | warning | Constraint failed: ipa-pat-3: 'To be usable for a wide range of internationally available applications, the Patient.name.text SHOULD be present.' (defined in http://hl7.org/fhir/uv/ipa/StructureDefinition/ipa-patient) (Best Practice Recommendation) |
Bundle.entry[1].resource/*Device/Telma.FEEDDADADEADBEEF*/.identifier[0].type (l64/c14) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers|1.0.0 |
Bundle.entry[1].resource/*Device/Telma.FEEDDADADEADBEEF*/.property[0].valueCode[0] (l155/c16) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD|1.0.0 |
Bundle.entry[1].resource/*Device/Telma.FEEDDADADEADBEEF*/.property[0].valueCode[1] (l164/c16) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD|1.0.0 |
Bundle.entry[1].resource/*Device/Telma.FEEDDADADEADBEEF*/.property[0].valueCode[2] (l173/c16) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD|1.0.0 |
Bundle.entry[1].resource/*Device/Telma.FEEDDADADEADBEEF*/.property[1].valueCode[0] (l196/c16) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS|1.0.0 |
Bundle.entry[1].resource/*Device/Telma.FEEDDADADEADBEEF*/.property[3].type (l233/c14) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7|1.0.0 |
Bundle.entry[2].resource/*Device/BPMonitor.C4F312FFFE53F2C9*/.identifier[0].type (l275/c14) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers|1.0.0 |
Bundle.entry[2].resource/*Device/BPMonitor.C4F312FFFE53F2C9*/.identifier[1].type (l288/c14) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers|1.0.0 |
Bundle.entry[2].resource/*Device/BPMonitor.C4F312FFFE53F2C9*/.property[0].valueCode[0] (l395/c16) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD|1.0.0 |
Bundle.entry[2].resource/*Device/BPMonitor.C4F312FFFE53F2C9*/.property[2].type (l431/c14) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7|1.0.0 |
Bundle.entry[2].resource/*Device/BPMonitor.C4F312FFFE53F2C9*/.property[3].type (l453/c14) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7|1.0.0 |
Bundle.entry[2].resource/*Device/BPMonitor.C4F312FFFE53F2C9*/.property[4].type (l475/c14) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7|1.0.0 |
Bundle.entry[5].resource/*Observation/BloodPressure.Poul.643992*/.code.coding[2].system (l636/c10) | warning | A definition for CodeSystem 'urn:oid:1.2.208.176.2.4' could not be found, so the code cannot be validated (from http://tx.fhir.org/r4) |
Bundle.entry[5].resource/*Observation/BloodPressure.Poul.643992*/.component[0].code.coding[2].system (l667/c14) | warning | A definition for CodeSystem 'http://medcomfhir.dk/ig/terminology/CodeSystem/medcom-observation-codes' could not be found, so the code cannot be validated (from http://tx.fhir.org/r4) |
Bundle.entry[5].resource/*Observation/BloodPressure.Poul.643992*/.component[1].code.coding[2] (l695/c14) | warning | A definition for CodeSystem 'http://medcomfhir.dk/ig/terminology/CodeSystem/medcom-observation-codes' could not be found, so the code cannot be validated |
Bundle.entry[5].resource/*Observation/BloodPressure.Poul.643992*/.code.coding[2] (l636/c10) | warning | A definition for CodeSystem 'urn:oid:1.2.208.176.2.4' could not be found, so the code cannot be validated |
Bundle.entry[5].resource/*Observation/BloodPressure.Poul.643992*/.component[0].code.coding[2] (l667/c14) | warning | A definition for CodeSystem 'http://medcomfhir.dk/ig/terminology/CodeSystem/medcom-observation-codes' could not be found, so the code cannot be validated |
Bundle.entry[6].resource/*Observation/HeartRate.Poul.1974654*/.code.coding[2].system (l794/c10) | warning | A definition for CodeSystem 'urn:oid:1.2.208.176.2.1' could not be found, so the code cannot be validated (from http://tx.fhir.org/r4) |
Bundle.entry[7].resource/*Observation/BloodPressureStatus.Poul.133527*/.component[0].code (l890/c14) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7|1.0.0 |
Path | Severity | Message |
Bundle.entry[0].resource/*Patient/Max*/.name[0] (l24/c12) | warning | Constraint failed: ipa-pat-3: 'To be usable for a wide range of internationally available applications, the Patient.name.text SHOULD be present.' (defined in http://hl7.org/fhir/uv/ipa/StructureDefinition/ipa-patient) (Best Practice Recommendation) |
Bundle.entry[1].resource/*Observation/MaxConsciousness*/ (l50/c8) | warning | Best Practice Recommendation: In general, all observations should have a performer |
Bundle.entry[2].resource/*Observation/MaxBloodPressure*/.code.coding[1] (l123/c10) | warning | A definition for CodeSystem 'urn:oid:1.2.208.176.2.4' could not be found, so the code cannot be validated |
Bundle.entry[2].resource/*Observation/MaxBloodPressure*/ (l105/c8) | warning | Best Practice Recommendation: In general, all observations should have a performer |
Bundle.entry[3].resource/*Observation/MaxBodyTemperature*/.code.coding[1] (l216/c10) | warning | A definition for CodeSystem 'urn:oid:1.2.208.176.2.4' could not be found, so the code cannot be validated |
Bundle.entry[3].resource/*Observation/MaxBodyTemperature*/ (l198/c8) | warning | Best Practice Recommendation: In general, all observations should have a performer |
Bundle.entry[4].resource/*Observation/MaxHeartRate*/.code.coding[1] (l271/c10) | warning | A definition for CodeSystem 'urn:oid:1.2.208.176.2.4' could not be found, so the code cannot be validated |
Bundle.entry[4].resource/*Observation/MaxHeartRate*/ (l253/c8) | warning | Best Practice Recommendation: In general, all observations should have a performer |
Bundle.entry[5].resource/*Observation/MaxRespirationRate*/ (l308/c8) | warning | Best Practice Recommendation: In general, all observations should have a performer |
Bundle.entry[6].resource/*Observation/MaxGlasgowComaScale*/ (l364/c8) | warning | Best Practice Recommendation: In general, all observations should have a performer |
Bundle.entry[6].resource/*Observation/MaxGlasgowComaScale*/.value.ofType(Quantity) (l385/c10) | warning | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
Bundle.entry[6].resource/*Observation/MaxGlasgowComaScale*/.referenceRange[0].high (l392/c14) | warning | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
Bundle.entry[6].resource/*Observation/MaxGlasgowComaScale*/.referenceRange[1].low (l402/c14) | warning | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
Bundle.entry[6].resource/*Observation/MaxGlasgowComaScale*/.referenceRange[1].high (l407/c14) | warning | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
Bundle.entry[6].resource/*Observation/MaxGlasgowComaScale*/.referenceRange[2].low (l417/c14) | warning | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
Bundle.entry[1].resource (l50/c8) | warning | Best Practice Recommendation: In general, all observations should have a performer |
Bundle.entry[2].resource (l105/c8) | warning | Best Practice Recommendation: In general, all observations should have a performer |
Bundle.entry[3].resource (l198/c8) | warning | Best Practice Recommendation: In general, all observations should have a performer |
Bundle.entry[4].resource (l253/c8) | warning | Best Practice Recommendation: In general, all observations should have a performer |
Bundle.entry[5].resource (l308/c8) | warning | Best Practice Recommendation: In general, all observations should have a performer |
Bundle.entry[6].resource (l364/c8) | warning | Best Practice Recommendation: In general, all observations should have a performer |
Path | Severity | Message |
Device.identifier[0].type (l12/c8) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers|1.0.0 |
Device.identifier[1].type (l25/c8) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers|1.0.0 |
Device.property[0].valueCode[0] (l132/c10) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD|1.0.0 |
Device.property[2].type (l168/c8) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7|1.0.0 |
Device.property[3].type (l190/c8) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7|1.0.0 |
Device.property[4].type (l212/c8) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7|1.0.0 |
Path | Severity | Message |
Device.identifier[0].type (l12/c8) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers|1.0.0 |
Device.property[0].valueCode[0] (l103/c10) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD|1.0.0 |
Device.property[0].valueCode[1] (l112/c10) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD|1.0.0 |
Device.property[0].valueCode[2] (l121/c10) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD|1.0.0 |
Device.property[1].valueCode[0] (l144/c10) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS|1.0.0 |
Device.property[3].type (l181/c8) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7|1.0.0 |
Path | Severity | Message |
Device.identifier[0].type (l12/c8) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers|1.0.0 |
Device.identifier[1].type (l25/c8) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers|1.0.0 |
Device.property[0].valueCode[0] (l132/c10) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD|1.0.0 |
Device.property[2].type (l168/c8) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7|1.0.0 |
Device.property[3].type (l190/c8) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7|1.0.0 |
Device.property[4].type (l212/c8) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7|1.0.0 |
Path | Severity | Message |
Observation.value.ofType(Quantity) (l22/c4) | warning | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
Observation.referenceRange[0].high (l29/c8) | warning | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
Observation.referenceRange[1].low (l39/c8) | warning | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
Observation.referenceRange[1].high (l44/c8) | warning | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
Observation.referenceRange[2].low (l54/c8) | warning | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
Observation (l1/c2) | warning | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Bundle-MaxTOKS.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Bundle-MaxTOKS.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Bundle-MaxTOKS.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Bundle-MaxTOKS.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Bundle-MaxTOKS.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Bundle-MaxTOKS.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Bundle-MaxTOKS.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Bundle-MaxTOKS.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Bundle-MaxTOKS.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Bundle-MaxTOKS.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Bundle-MaxTOKS.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Bundle-MaxTOKS.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Observation-ElsePainVRS.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Observation-ElseUrinStix.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Observation-MaxBloodPressure.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Observation-MaxBodyTemperature.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Observation-MaxConsciousness.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Observation-MaxGlasgowComaScale.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Observation-MaxHeartRate.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Observation-MaxRespirationRate.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Observation-MaxSaturation.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Observation-MaxVitalSignsPanel.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Bundle-MaxTOKS.json | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
fsh-generated/resources/Bundle-MaxTOKS.json | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
fsh-generated/resources/Bundle-MaxTOKS.json | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
fsh-generated/resources/Bundle-MaxTOKS.json | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
fsh-generated/resources/Bundle-MaxTOKS.json | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
fsh-generated/resources/Observation-MaxGlasgowComaScale.json | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
fsh-generated/resources/Observation-MaxGlasgowComaScale.json | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
fsh-generated/resources/Observation-MaxGlasgowComaScale.json | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
fsh-generated/resources/Observation-MaxGlasgowComaScale.json | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
fsh-generated/resources/Observation-MaxGlasgowComaScale.json | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |