CH LAB-Order (R4), published by HL7 Switzerland. This guide is not an authorized publication; it is the continuous build for version 3.0.0-ci-build built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7ch/ch-lab-order/ and changes regularly. See the Directory of published versions
Generated Narrative: SpecimenDefinition
ResourceSpecimenDefinition "Urine-Spot" (Language"en-US")
Profile: Laboratory IVD Specimen Definition
typeCollected: Urine (specimenType#UR)
collection: Urine specimen (specimen) (SNOMED CT#122575003)
typeTested
type: Urine (specimenType#UR)
preference: preferred
Containers
Material Type Cap Description Capacity MinimumVolume[x] plastic (SNOMED CT#61088005 "Plastic (substance)") Midstream urine specimen container (physical object) (SNOMED CT#702224000) yellow cap (ContainerCap#yellow) yellow cap plastic tube 5 mL 5 milliliter (Details: UCUM codemL = 'mL') 0.5 milliliter (Details: UCUM codemL = 'mL') RetentionTimes
Value Unit System Code 24 hour Unified Code for Units of Measure (UCUM) h rejectionCriterion: insufficient quantity of specimen (RejectionCriterion#insufficient)
handling
temperatureQualifier: 2-8°C ()
MaxDurations
Value Unit System Code 14 day Unified Code for Units of Measure (UCUM) d handling
temperatureQualifier: -20° ()
MaxDurations
Value Unit System Code 1 year Unified Code for Units of Measure (UCUM) ear