CH LAB-Order (R4)
3.0.0-ci-build - ci-build Switzerland flag

CH LAB-Order (R4), published by HL7 Switzerland. This guide is not an authorized publication; it is the continuous build for version 3.0.0-ci-build built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7ch/ch-lab-order/ and changes regularly. See the Directory of published versions

: ObservationDefinition Sodium in blood - XML Representation

Raw xml | Download


<ObservationDefinition xmlns="http://hl7.org/fhir">
  <id value="observation-serum-sodium"/>
  <meta>
    <profile
             value="http://fhir.ch/ig/ch-lab-order/StructureDefinition/ch-lab-labobservationdefinition-r4"/>
  </meta>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: ObservationDefinition observation-serum-sodium</b></p><a name="observation-serum-sodium"> </a><a name="hcobservation-serum-sodium"> </a><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px"/><p style="margin-bottom: 0px">Profile: <a href="StructureDefinition-ch-lab-labobservationdefinition-r4.html">CH Lab Observation Definition (R4)</a></p></div><p><b>code</b>: <span title="Codes:{http://loinc.org 2947-0}">Sodium [Moles/volume] in Blood</span></p><p><b>permittedDataType</b>: Quantity, string</p><p><b>multipleResultsAllowed</b>: false</p><p><b>method</b>: <span title="Codes:{http://snomed.info/sct 703445001}">Ion Selective Electrode (ISE)</span></p><p><b>preferredReportName</b>: sodium</p><h3>QuantitativeDetails</h3><table class="grid"><tr><td style="display: none">-</td><td><b>CustomaryUnit</b></td><td><b>Unit</b></td><td><b>DecimalPrecision</b></td></tr><tr><td style="display: none">*</td><td><span title="Codes:{http://unitsofmeasure.org g/L}">g/L</span></td><td><span title="Codes:{http://unitsofmeasure.org mmol/L}">mmol/L</span></td><td>0</td></tr></table><h3>QualifiedIntervals</h3><table class="grid"><tr><td style="display: none">-</td><td><b>Category</b></td><td><b>Range</b></td><td><b>Context</b></td></tr><tr><td style="display: none">*</td><td>reference range</td><td>135-145</td><td><span title="Codes:{http://terminology.hl7.org/CodeSystem/referencerange-meaning normal}">Normal Range</span></td></tr></table></div>
  </text>
  <code>
    <coding>
      <system value="http://loinc.org"/>
      <code value="2947-0"/>
      <display value="Sodium [Moles/volume] in Blood"/>
    </coding>
  </code>
  <permittedDataType value="Quantity"/>
  <permittedDataType value="string"/>
  <multipleResultsAllowed value="false"/>
  <method>
    <coding>
      <system value="http://snomed.info/sct"/>
      <code value="703445001"/>
      <display
               value="Ion selective electrode measurement technique (qualifier value)"/>
    </coding>
    <text value="Ion Selective Electrode (ISE)"/>
  </method>
  <preferredReportName value="sodium"/>
  <quantitativeDetails>
    <customaryUnit>
      <coding>
        <system value="http://unitsofmeasure.org"/>
        <code value="g/L"/>
      </coding>
    </customaryUnit>
    <unit>
      <coding>
        <system value="http://unitsofmeasure.org"/>
        <code value="mmol/L"/>
      </coding>
    </unit>
    <decimalPrecision value="0"/>
  </quantitativeDetails>
  <qualifiedInterval>
    <category value="reference"/>
    <range>
      <low>
        <value value="135"/>
        <system value="http://unitsofmeasure.org"/>
        <code value="mmol/L"/>
      </low>
      <high>
        <value value="145"/>
        <system value="http://unitsofmeasure.org"/>
        <code value="mmol/L"/>
      </high>
    </range>
    <context>
      <coding>
        <system
                value="http://terminology.hl7.org/CodeSystem/referencerange-meaning"/>
        <code value="normal"/>
        <display value="Normal Range"/>
      </coding>
    </context>
  </qualifiedInterval>