CH LAB-Order (R4)
3.0.0 - ci-build
CH LAB-Order (R4), published by HL7 Switzerland. This guide is not an authorized publication; it is the continuous build for version 3.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7ch/ch-lab-order/ and changes regularly. See the Directory of published versions
Draft as of 2024-12-13 |
<ActivityDefinition xmlns="http://hl7.org/fhir">
<id value="procedure-lab-panel-renal-insufficiency"/>
<meta>
<profile
value="http://hl7.org/fhir/uv/order-catalog/StructureDefinition/LabProcedureDefinition"/>
</meta>
<language value="en-US"/>
<text>
<status value="extensions"/>
<div xmlns="http://www.w3.org/1999/xhtml" xml:lang="en-US" lang="en-US"><p><b style="color: maroon">Exception generating Narrative: Error @1, 17: Premature ExpressionNode termination at unexpected token "=="</b></p></div>
</text>
<url
value="http://fhir.ch/ig/ch-lab-order/ActivityDefinition/procedure-lab-panel-renal-insufficiency"/>
<identifier>
<system value="urn:ietf:rfc:3986"/>
<value value="urn:oid:2.16.840.1.113883.4.642.19.7.100"/>
</identifier>
<version value="3.0.0"/>
<title value="Procedure for renal insufficiency assessment panel"/>
<status value="draft"/>
<experimental value="false"/>
<date value="2024-12-13T18:00:00+01:00"/>
<publisher value="HL7 Switzerland"/>
<contact>
<name value="HL7 Switzerland"/>
<telecom>
<system value="url"/>
<value value="https://www.hl7.ch"/>
</telecom>
</contact>
<contact>
<name value="Marcel Hanselmann"/>
<telecom>
<system value="email"/>
<value value="laborprojektgruppe@gmail.com"/>
<use value="work"/>
</telecom>
</contact>
<description value="Order Panel for chronic renal insufficiency"/>
<jurisdiction>
<coding>
<system value="urn:iso:std:iso:3166"/>
<code value="CH"/>
</coding>
</jurisdiction>
<copyright value="CC0-1.0"/>
<relatedArtifact>
<type value="documentation"/>
<display
value="Explanation of diagnostic tests used for assessment of stable renal insufficiency"/>
</relatedArtifact>
<kind value="ServiceRequest"/>
<code>
<coding>
<system value="http://snomed.info/sct"/>
<code value="441915005"/>
<display value="Measurement of renal function (procedure)"/>
</coding>
</code>
<intent value="order"/>
<specimenRequirement>🔗
<reference value="SpecimenDefinition/single-test-serum-venous"/>
</specimenRequirement>
<observationResultRequirement>🔗
<reference value="ObservationDefinition/observationAlbuminUrine"/>
</observationResultRequirement>
<observationResultRequirement>🔗
<reference value="ObservationDefinition/observationCreatinineUrine"/>
</observationResultRequirement>
<observationResultRequirement>🔗
<reference value="ObservationDefinition/observation-uACR"/>
</observationResultRequirement>
<observationResultRequirement>🔗
<reference value="ObservationDefinition/observationCreatinineSerum"/>
</observationResultRequirement>
</ActivityDefinition>