Validation Results for XpandhIg

Generated Mon Mar 31 07:05:05 UTC 2025, FHIR version 4.0.1 for hl7.eu.fhir.xpandh#0.1.0 (canonical = http://hl7.eu/fhir/ig/xpandh (history)). See Errors Only & IP

Quality Checks
Publisher Version:IG Publisher Version: v1.8.22
Publication Code:n/a . PackageId = hl7.eu.fhir.xpandh, Canonical = http://hl7.eu/fhir/ig/xpandh
Realm Check for n/a:
  • n/a
Language Info:This IG has no language information
Publication Request:
  • This IG has never been published
  • No publication request found
Supressed Messages:5 Suppressed Issues
Dependency Checks:
PackageVersionFHIRCanonicalWeb BaseComment
.. hl7.eu.fhir.xpandh0.1.0R4http://hl7.eu/fhir/ig/xpandhHL7 Packages must have an id that starts with hl7.cda., hl7.fhir., hl7.v2., or hl7.ehrs.
... hl7.terminology.r46.2.0 UR4http://terminology.hl7.orghttp://terminology.hl7.org/6.2.0
... hl7.fhir.uv.extensions.r45.2.0 MR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0
... hl7.fhir.uv.ips1.1.0 MR4http://hl7.org/fhir/uv/ipshttp://hl7.org/fhir/uv/ips/STU1.1
.... hl7.terminology.r45.0.0 UR4http://terminology.hl7.orghttp://terminology.hl7.org/5.0.0
.... fhir.dicom2022.4.20221006 OR4http://fhir.org/packages/fhir.dicomhttp://fhir.org/packages/fhir.dicomLatest Release is 2025.1.20250221
Templates: xpandh.fhir.template#0.0.1 -> fhir.base.template#current. Tools: 0.4.1
Related IGs:n/a
Dependent IGs:no references
Global Profiles:(none declared)
Terminology Server(s):http://tx.fhir.org/r4 (details)
HTA Analysis:15 issues
R5 Dependencies:(none)
Draft Dependencies:
Modifier Extensions:(none)
Previous Version Comparison: Unable to compare with previous version: Unable to find version history at http://hl7.eu/fhir/ig/xpandh (Problem #1 with package-list.json at http://hl7.eu/fhir/ig/xpandh: Not Found)
IPA Comparison: n/a
IPS Comparison: n/a
Validation Flags: On: autoLoad; Off: hintAboutNonMustSupport, anyExtensionsAllowed, checkAggregation, showReferenceMessages, noExperimentalContent, displayWarnings
Summary: errors = 0, warn = 21, info = 2, broken links = 0, pinned = n/a.
FilenameErrorsWarningsHints
Build Errors020
/scratch/repo/fsh-generated/resources/ImplementationGuide-hl7.eu.fhir.xpandh000
/scratch/repo/fsh-generated/resources/StructureDefinition-Patient-eu-xpandh031
/scratch/repo/fsh-generated/resources/ValueSet-eHDSIAbsentOrUnknownAllergy000
/scratch/repo/fsh-generated/resources/ValueSet-eHDSIAbsentOrUnknownDevice000
/scratch/repo/fsh-generated/resources/ValueSet-eHDSIAbsentOrUnknownMedication000
/scratch/repo/fsh-generated/resources/ValueSet-eHDSIAbsentOrUnknownProblem000
/scratch/repo/fsh-generated/resources/ValueSet-eHDSIAbsentOrUnknownProcedure000
/scratch/repo/fsh-generated/resources/ValueSet-eHDSIAdverseEventType000
/scratch/repo/fsh-generated/resources/ValueSet-eHDSIAllergenNoDrug000
/scratch/repo/fsh-generated/resources/ValueSet-eHDSIAllergyCertainty010
/scratch/repo/fsh-generated/resources/ValueSet-eHDSIAllergyStatus010
/scratch/repo/fsh-generated/resources/ValueSet-eHDSIBloodGroup000
/scratch/repo/fsh-generated/resources/ValueSet-eHDSIBloodPressure000
/scratch/repo/fsh-generated/resources/ValueSet-eHDSICertainty010
/scratch/repo/fsh-generated/resources/ValueSet-eHDSICodeProb000
/scratch/repo/fsh-generated/resources/ValueSet-eHDSIConfidentiality010
/scratch/repo/fsh-generated/resources/ValueSet-eHDSICountry000
/scratch/repo/fsh-generated/resources/ValueSet-eHDSICriticality000
/scratch/repo/fsh-generated/resources/ValueSet-eHDSICurrentPregnancyStatus000
/scratch/repo/fsh-generated/resources/ValueSet-eHDSIDocumentCode000
/scratch/repo/fsh-generated/resources/ValueSet-eHDSIDoseForm020
/scratch/repo/fsh-generated/resources/ValueSet-eHDSIHealthcareProfessionalRole000
/scratch/repo/fsh-generated/resources/ValueSet-eHDSIHospitalDischargeReportType000
/scratch/repo/fsh-generated/resources/ValueSet-eHDSIProcedure001
/scratch/repo/fsh-generated/resources/ValueSet-eHDSIReactionAllergy000
/scratch/repo/fsh-generated/resources/ValueSet-eHDSISeverity000
/scratch/repo/fsh-generated/resources/ValueSet-eHDSISocialHistory000
/scratch/repo/fsh-generated/resources/ValueSet-eHDSIVaccine0100

n/a Show Validation Information

output/index.htmlwarningThe html source has duplicate anchor Ids: mission
IGwarningThe IG is not for the international realm, and it uses SNOMED CT, so it should fix the SCT edition in the expansion parameters

fsh-generated/resources/ImplementationGuide-hl7.eu.fhir.xpandh.json Show Validation Information (1)


fsh-generated/resources/StructureDefinition-Patient-eu-xpandh.json Show Validation Information (1)

PathSeverityMessage
StructureDefinition​.snapshot​.element[4]​.binding​.extension[0] (l1​/c46936)informationThe extension http://hl7.org/fhir/StructureDefinition/elementdefinition-maxValueSet|5.2.0 is deprecated MSG_DEPENDS_ON_DEPRECATED
StructureDefinition​.snapshot​.element[8]​.type[0]​.profile[0] (l1​/c50729)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/patient-nationality'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer. Using version '5.2.0', found versions: 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/patient-nationality' to 'http://hl7.org/fhir/StructureDefinition/patient-nationality|5.2.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.differential​.element[2]​.type[0]​.profile[0] (l1​/c121731)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/patient-nationality'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer. Using version '5.2.0', found versions: 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/patient-nationality' to 'http://hl7.org/fhir/StructureDefinition/patient-nationality|5.2.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.where(url = 'http:​/​/hl7​.eu​/fhir​/ig​/xpandh​/StructureDefinition​/Patient-eu-xpandh')warningThe Implementation Guide contains no examples for this profile

fsh-generated/resources/ValueSet-eHDSIAbsentOrUnknownAllergy.json Show Validation Information (1)


fsh-generated/resources/ValueSet-eHDSIAbsentOrUnknownDevice.json Show Validation Information (1)


fsh-generated/resources/ValueSet-eHDSIAbsentOrUnknownMedication.json Show Validation Information (1)


fsh-generated/resources/ValueSet-eHDSIAbsentOrUnknownProblem.json Show Validation Information (1)


fsh-generated/resources/ValueSet-eHDSIAbsentOrUnknownProcedure.json Show Validation Information (1)


fsh-generated/resources/ValueSet-eHDSIAdverseEventType.json Show Validation Information (1)


fsh-generated/resources/ValueSet-eHDSIAllergenNoDrug.json Show Validation Information (1)


fsh-generated/resources/ValueSet-eHDSIAllergyCertainty.json Show Validation Information (1)

PathSeverityMessage
ValueSet.compose.include[0] (l1/c2627)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/CodeSystem/allergyintolerance-verification'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer. Using version '1.0.1', found versions: 0.5.0, 1.0.1. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/CodeSystem/allergyintolerance-verification' to 'http://terminology.hl7.org/CodeSystem/allergyintolerance-verification|1.0.1'

fsh-generated/resources/ValueSet-eHDSIAllergyStatus.json Show Validation Information (1)

PathSeverityMessage
ValueSet.compose.include[0] (l1/c2429)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/CodeSystem/allergyintolerance-clinical'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer. Using version '1.0.1', found versions: 0.5.0, 1.0.1. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/CodeSystem/allergyintolerance-clinical' to 'http://terminology.hl7.org/CodeSystem/allergyintolerance-clinical|1.0.1'

fsh-generated/resources/ValueSet-eHDSIBloodGroup.json Show Validation Information (1)


fsh-generated/resources/ValueSet-eHDSIBloodPressure.json Show Validation Information (1)


fsh-generated/resources/ValueSet-eHDSICertainty.json Show Validation Information (1)

PathSeverityMessage
ValueSet.compose.include[0] (l1/c2906)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/CodeSystem/condition-ver-status'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer. Using version '2.0.1', found versions: 0.5.0, 2.0.1. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/CodeSystem/condition-ver-status' to 'http://terminology.hl7.org/CodeSystem/condition-ver-status|2.0.1'

fsh-generated/resources/ValueSet-eHDSICodeProb.json Show Validation Information (1)


fsh-generated/resources/ValueSet-eHDSIConfidentiality.json Show Validation Information (1)

PathSeverityMessage
ValueSet.compose.include[0] (l1/c6976)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/CodeSystem/v3-Confidentiality'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer. Using version '3.0.0', found versions: 2.2.0, 3.0.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/CodeSystem/v3-Confidentiality' to 'http://terminology.hl7.org/CodeSystem/v3-Confidentiality|3.0.0'

fsh-generated/resources/ValueSet-eHDSICountry.json Show Validation Information (1)


fsh-generated/resources/ValueSet-eHDSICriticality.json Show Validation Information (1)


fsh-generated/resources/ValueSet-eHDSICurrentPregnancyStatus.json Show Validation Information (1)


fsh-generated/resources/ValueSet-eHDSIDocumentCode.json Show Validation Information (1)


fsh-generated/resources/ValueSet-eHDSIDoseForm.json Show Validation Information (1)

PathSeverityMessage
ValueSet.compose.include[0]warningUnknown System 'https://standardterms.edqm.eu' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'https://standardterms.edqm.eu' could not be found, so the code cannot be validated) VALUESET_UNC_SYSTEM_WARNING
ValueSet.where(id = 'eHDSIDoseForm')warningError from http://tx.fhir.org/r4: Unable to provide support for code system https://standardterms.edqm.eu (from server, see log)

fsh-generated/resources/ValueSet-eHDSIHealthcareProfessionalRole.json Show Validation Information (1)


fsh-generated/resources/ValueSet-eHDSIHospitalDischargeReportType.json Show Validation Information (1)


fsh-generated/resources/ValueSet-eHDSIProcedure.json Show Validation Information (1)

PathSeverityMessage
ValueSet​.compose​.include[0] (l1​/c188582)informationThe value set include has too many codes to validate (1,052), so each individual code has not been checked VALUESET_INC_TOO_MANY_CODES

fsh-generated/resources/ValueSet-eHDSIReactionAllergy.json Show Validation Information (1)


fsh-generated/resources/ValueSet-eHDSISeverity.json Show Validation Information (1)


fsh-generated/resources/ValueSet-eHDSISocialHistory.json Show Validation Information (1)


fsh-generated/resources/ValueSet-eHDSIVaccine.json Show Validation Information (1)

PathSeverityMessage
ValueSet.compose.include[0].concept[15]warningThe code 'J07AG54' is not valid in the system http://www.whocc.no/atc (Unknown code 'J07AG54' in the CodeSystem 'http://www.whocc.no/atc' version '2020-05')
ValueSet.compose.include[0].concept[52]warningThe code 'J07AX01' is not valid in the system http://www.whocc.no/atc (Unknown code 'J07AX01' in the CodeSystem 'http://www.whocc.no/atc' version '2020-05')
ValueSet.compose.include[0].concept[97]warningThe code 'J07BN' is not valid in the system http://www.whocc.no/atc (Unknown code 'J07BN' in the CodeSystem 'http://www.whocc.no/atc' version '2020-05')
ValueSet.compose.include[0].concept[98]warningThe code 'J07BN01' is not valid in the system http://www.whocc.no/atc (Unknown code 'J07BN01' in the CodeSystem 'http://www.whocc.no/atc' version '2020-05')
ValueSet.compose.include[0].concept[99]warningThe code 'J07BN02' is not valid in the system http://www.whocc.no/atc (Unknown code 'J07BN02' in the CodeSystem 'http://www.whocc.no/atc' version '2020-05')
ValueSet​.compose​.include[0]​.concept[100]warningThe code 'J07BN03' is not valid in the system http://www.whocc.no/atc (Unknown code 'J07BN03' in the CodeSystem 'http://www.whocc.no/atc' version '2020-05')
ValueSet​.compose​.include[0]​.concept[101]warningThe code 'J07BN04' is not valid in the system http://www.whocc.no/atc (Unknown code 'J07BN04' in the CodeSystem 'http://www.whocc.no/atc' version '2020-05')
ValueSet​.compose​.include[0]​.concept[105]warningThe code 'J07BX04' is not valid in the system http://www.whocc.no/atc (Unknown code 'J07BX04' in the CodeSystem 'http://www.whocc.no/atc' version '2020-05')
ValueSet​.compose​.include[0]​.concept[120]warningThe code 'J07XA' is not valid in the system http://www.whocc.no/atc (Unknown code 'J07XA' in the CodeSystem 'http://www.whocc.no/atc' version '2020-05')
ValueSet​.compose​.include[0]​.concept[121]warningThe code 'J07XA01' is not valid in the system http://www.whocc.no/atc (Unknown code 'J07XA01' in the CodeSystem 'http://www.whocc.no/atc' version '2020-05')

Suppressed Messages (Warnings, hints, broken links)

No schematrons available for Logical Models

Errors sorted by type


MSG_DEPENDS_ON_DEPRECATED

fsh-generated/resources/StructureDefinition-Patient-eu-xpandh.jsonThe extension http://hl7.org/fhir/StructureDefinition/elementdefinition-maxValueSet|5.2.0 is deprecated

TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS

fsh-generated/resources/StructureDefinition-Patient-eu-xpandh.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/patient-nationality'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer. Using version '5.2.0', found versions: 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/patient-nationality' to 'http://hl7.org/fhir/StructureDefinition/patient-nationality|5.2.0'
fsh-generated/resources/StructureDefinition-Patient-eu-xpandh.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/patient-nationality'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer. Using version '5.2.0', found versions: 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/patient-nationality' to 'http://hl7.org/fhir/StructureDefinition/patient-nationality|5.2.0'

VALUESET_INC_TOO_MANY_CODES

fsh-generated/resources/ValueSet-eHDSIProcedure.jsonThe value set include has too many codes to validate (1,052), so each individual code has not been checked

VALUESET_UNC_SYSTEM_WARNING

fsh-generated/resources/ValueSet-eHDSIDoseForm.jsonUnknown System 'https://standardterms.edqm.eu' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'https://standardterms.edqm.eu' could not be found, so the code cannot be validated)