XpanDH Hospital Discharge Report
0.1.0 - ci-build 150

XpanDH Hospital Discharge Report, published by XpanDH Project. This guide is not an authorized publication; it is the continuous build for version 0.1.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7-eu/xpandh-hdr/ and changes regularly. See the Directory of published versions

Resource Profile: ObservationResultsPathologyXpandh - Detailed Descriptions

Draft as of 2025-01-06

Definitions for the Observation-results-pathology-eu-xpandh resource profile.

Guidance on how to interpret the contents of this table can be found here

0. Observation
Definition

This observation may represent the result of a simple pathology test such as hematocrit or it may group the set of results produced by a multi-test study or panel such as a complete blood count, a dynamic function test, a urine specimen study. In the latter case, the observation carries the overall conclusion of the study and references the atomic results of the study as "has-member" child observations


Measurements and simple assertions made about a patient, device or other subject.

ShortPathology result for a simple test or for a panel/studyMeasurements and simple assertions
Comments

Represents either a lab simple observation or the group of observations produced by a pathology study.


Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.

Control0..*
Is Modifierfalse
Summaryfalse
Alternate NamesVital Signs, Measurement, Results, Tests
Invariantsdom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources (contained.contained.empty())
dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource (contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty())
dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated (contained.meta.versionId.empty() and contained.meta.lastUpdated.empty())
dom-5: If a resource is contained in another resource, it SHALL NOT have a security label (contained.meta.security.empty())
dom-6: A resource should have narrative for robust management (text.`div`.exists())
obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present (dataAbsentReason.empty() or value.empty())
obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present (value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty())
ips-2: if no "hasMember" element is present then Observation must have a" value" (value.exists() or hasMember.exists())
obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present (dataAbsentReason.empty() or value.empty())
obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present (value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty())
2. Observation.implicitRules
Definition

A reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. Often, this is a reference to an implementation guide that defines the special rules along with other profiles etc.

ShortA set of rules under which this content was created
Comments

Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc.

Control0..1
Typeuri
Is Modifiertrue because This element is labeled as a modifier because the implicit rules may provide additional knowledge about the resource that modifies it's meaning or interpretation
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Summarytrue
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
4. Observation.modifierExtension
Definition

May be used to represent additional information that is not part of the basic definition of the resource and that modifies the understanding of the element that contains it and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

ShortExtensions that cannot be ignored
Comments

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

Control0..*
TypeExtension
Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the resource that contains them
Summaryfalse
Requirements

Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

Alternate Namesextensions, user content
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
6. Observation.status
Definition

The status of the result value.

Shortregistered | preliminary | final | amended +
Comments

This element is labeled as a modifier because the status contains codes that mark the resource as not currently valid.

Control1..1
BindingThe codes SHALL be taken from ObservationStatushttp://hl7.org/fhir/ValueSet/observation-status|4.0.1
(required to http://hl7.org/fhir/ValueSet/observation-status|4.0.1)

Codes providing the status of an observation.

Typecode
Is Modifiertrue because This element is labeled as a modifier because it is a status element that contains status entered-in-error which means that the resource should not be treated as valid
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Summarytrue
Requirements

Need to track the status of individual results. Some results are finalized before the whole report is finalized.

Fixed Valuefinal
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
8. Observation.category
Definition

A code that classifies the general type of observation being made. In this profile, fixed to "laboratory".


A code that classifies the general type of observation being made.

ShortConcept - reference to a terminology or just textClassification of type of observation
Comments

"laboratory" includes laboratory medicine and pathology


In addition to the required category valueset, this element allows various categorization schemes based on the owner’s definition of the category and effectively multiple categories can be used at once. The level of granularity is defined by the category concepts in the value set.

Control10..*
This element is affected by the following invariants: ele-1
BindingThe codes SHOULD be taken from ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category
(preferred to http://hl7.org/fhir/ValueSet/observation-category)

Codes for high level observation categories.

TypeCodeableConcept(Codeable Concept (IPS))
Is Modifierfalse
Requirements

Used for filtering what observations are retrieved and displayed.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
SlicingThis element introduces a set of slices on Observation.category. The slices areUnordered and Open, and can be differentiated using the following discriminators:
  • pattern @ $this
  • 10. Observation.category:laboratory
    Slice Namelaboratory
    Definition

    A concept that may be defined by a formal reference to a terminology or ontology or may be provided by text.


    A code that classifies the general type of observation being made.

    ShortConcept - reference to a terminology or just textClassification of type of observation
    Comments

    Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.


    In addition to the required category valueset, this element allows various categorization schemes based on the owner’s definition of the category and effectively multiple categories can be used at once. The level of granularity is defined by the category concepts in the value set.

    Control10..1*
    This element is affected by the following invariants: ele-1
    BindingThe codes SHOULD be taken from ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category
    (preferred to http://hl7.org/fhir/ValueSet/observation-category)

    Codes for high level observation categories.

    TypeCodeableConcept(Codeable Concept (IPS))
    Is Modifierfalse
    Must Supporttrue
    Requirements

    Used for filtering what observations are retrieved and displayed.

    Pattern Value{
      "coding" : [{
        "system" : "http://terminology.hl7.org/CodeSystem/observation-category",
        "code" : "laboratory"
      }]
    }
    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    12. Observation.code
    Definition

    Describes what was observed. Sometimes this is called the observation "name". In this profile this code represents either a simple laboratory test or a laboratory study with multiple child observations


    Describes what was observed. Sometimes this is called the observation "name".

    ShortConcept - reference to a terminology or just textType of observation (code / type)
    Comments

    In the context of this Observation-laboratory-uv-ips profile, when the observation plays the role of a grouper of member sub-observations, the code represent the group (for instance a panel code). In case no code is available, at least a text shall be provided.


    All code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

    Control1..1
    This element is affected by the following invariants: ele-1
    BindingUnless not suitable, these codes SHALL be taken from For example codes, see Results Pathology Observation - IPShttp://hl7.org/fhir/ValueSet/observation-codes
    (extensible to http://hl7.org/fhir/uv/ips/ValueSet/results-pathology-observations-uv-ips)
    TypeCodeableConcept(Codeable Concept (IPS))
    Is Modifierfalse
    Must Supporttrue
    Requirements

    Knowing what kind of observation is being made is essential to understanding the observation.

    Alternate NamesName
    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    14. Observation.subject
    Definition

    The patient, or group of patients, location, or device whose characteristics (direct or indirect) are described by the observation and into whose record the observation is placed. Comments: Indirect characteristics may be those of a specimen, fetus, donor, other observer (for example a relative or EMT), or any observation made about the subject.

    In this profile is constrained to the patient


    The patient, or group of patients, location, or device this observation is about and into whose record the observation is placed. If the actual focus of the observation is different from the subject (or a sample of, part, or region of the subject), the focus element or the code itself specifies the actual focus of the observation.

    ShortWho and/or what the observation is about
    Comments

    One would expect this element to be a cardinality of 1..1. The only circumstance in which the subject can be missing is when the observation is made by a device that does not know the patient. In this case, the observation SHALL be matched to a patient through some context/channel matching technique, and at this point, the observation should be updated.

    Control10..1
    TypeReference(Patient (IPS), Patient, Group, Device, Location)
    Is Modifierfalse
    Must Supporttrue
    Summarytrue
    Requirements

    Observations have no value if you don't know who or what they're about.

    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    16. Observation.subject.reference
    Definition

    A reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources.

    ShortLiteral reference, Relative, internal or absolute URL
    Comments

    Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.

    Control10..1
    This element is affected by the following invariants: ref-1
    Typestring
    Is Modifierfalse
    Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
    Must Supporttrue
    Summarytrue
    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    18. Observation.effective[x]
    Definition

    The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.

    ShortClinically relevant time/time-period for observation
    Comments

    At least a date should be present unless this observation is a historical report. For recording imprecise or "fuzzy" times (For example, a blood glucose measurement taken "after breakfast") use the Timing datatype which allow the measurement to be tied to regular life events.

    Control10..1
    TypeChoice of: dateTime, Period, Timing, instant
    [x] NoteSeeChoice of Data Typesfor further information about how to use [x]
    Is Modifierfalse
    Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
    Must Supporttrue
    Must Support TypesNo must-support rules about the choice of types/profiles
    Summarytrue
    Requirements

    Knowing when an observation was deemed true is important to its relevance as well as determining trends.

    Alternate NamesOccurrence
    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    20. Observation.effective[x].extension:data-absent-reason
    Slice Namedata-absent-reason
    Definition

    Provides a reason why the effectiveTime is missing.

    Shorteffective[x] absence reason
    Control0..1
    TypeExtension(Data Absent Reason) (Extension Type: code)
    Is Modifierfalse
    Must Supporttrue
    Summaryfalse
    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
    22. Observation.performer
    Definition

    Who was responsible for asserting the observed value as "true".

    ShortWho is responsible for the observation
    Control10..*
    TypeReference(Practitioner (IPS), PractitionerRole (IPS), Organization (IPS), CareTeam, Patient (IPS), RelatedPerson, Practitioner, PractitionerRole, Organization, Patient)
    Is Modifierfalse
    Must Supporttrue
    Must Support TypesNo must-support rules about the choice of types/profiles
    Summarytrue
    Requirements

    May give a degree of confidence in the observation and also indicates where follow-up questions should be directed.

    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    24. Observation.value[x]
    Definition

    The information determined as a result of making the observation, if the information has a simple value.

    ShortActual result
    Comments

    An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.

    Control0..1
    This element is affected by the following invariants: obs-7
    TypeChoice of: Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period
    [x] NoteSeeChoice of Data Typesfor further information about how to use [x]
    Is Modifierfalse
    Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
    Must Supporttrue
    Must Support TypesNo must-support rules about the choice of types/profiles
    Summarytrue
    Requirements

    An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    SlicingThis element introduces a set of slices on Observation.value[x]. The slices areUnordered and Open, and can be differentiated using the following discriminators:
    • type @ $this
    • 26. Observation.value[x]:valueString
      Slice NamevalueString
      Definition

      The information determined as a result of making the observation, if the information has a simple value.

      ShortActual result
      Comments

      An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.

      Control0..1
      This element is affected by the following invariants: obs-7
      Typestring, dateTime, boolean, SampledData, Quantity, Period, Ratio, integer, time, Range, CodeableConcept
      [x] NoteSeeChoice of Data Typesfor further information about how to use [x]
      Is Modifierfalse
      Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
      Must Supporttrue
      Summarytrue
      Requirements

      An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      28. Observation.value[x]:valueRange
      Slice NamevalueRange
      Definition

      A set of ordered Quantities defined by a low and high limit.


      The information determined as a result of making the observation, if the information has a simple value.

      ShortSet of values bounded by low and highActual result
      Comments

      The stated low and high value are assumed to have arbitrarily high precision when it comes to determining which values are in the range. I.e. 1.99 is not in the range 2 -> 3.


      An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.

      Control0..1
      This element is affected by the following invariants: ele-1, obs-7
      TypeRange(Range (IPS)), dateTime, boolean, string, SampledData, Quantity, Period, Ratio, integer, time, CodeableConcept
      [x] NoteSeeChoice of Data Typesfor further information about how to use [x]
      Is Modifierfalse
      Must Supporttrue
      Requirements

      An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      rng-2: If present, low SHALL have a lower value than high (low.empty() or high.empty() or (low <= high))
      30. Observation.value[x]:valueRatio
      Slice NamevalueRatio
      Definition

      A relationship of two Quantity values - expressed as a numerator and a denominator.


      The information determined as a result of making the observation, if the information has a simple value.

      ShortA ratio of two Quantity values - a numerator and a denominatorActual result
      Comments

      The Ratio datatype should only be used to express a relationship of two numbers if the relationship cannot be suitably expressed using a Quantity and a common unit. Where the denominator value is known to be fixed to "1", Quantity should be used instead of Ratio.


      An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.

      Control0..1
      This element is affected by the following invariants: ele-1, obs-7
      TypeRatio(Ratio (IPS)), dateTime, boolean, string, SampledData, Quantity, Period, integer, time, Range, CodeableConcept
      [x] NoteSeeChoice of Data Typesfor further information about how to use [x]
      Is Modifierfalse
      Must Supporttrue
      Requirements

      An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      rat-1: Numerator and denominator SHALL both be present, or both are absent. If both are absent, there SHALL be some extension present ((numerator.empty() xor denominator.exists()) and (numerator.exists() or extension.exists()))
      32. Observation.value[x]:valueTime
      Slice NamevalueTime
      Definition

      The information determined as a result of making the observation, if the information has a simple value.

      ShortActual result
      Comments

      An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.

      Control0..1
      This element is affected by the following invariants: obs-7
      Typetime, dateTime, boolean, string, SampledData, Quantity, Period, Ratio, integer, Range, CodeableConcept
      [x] NoteSeeChoice of Data Typesfor further information about how to use [x]
      Is Modifierfalse
      Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
      Must Supporttrue
      Summarytrue
      Requirements

      An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      34. Observation.value[x]:valueDateTime
      Slice NamevalueDateTime
      Definition

      The information determined as a result of making the observation, if the information has a simple value.

      ShortActual result
      Comments

      An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.

      Control0..1
      This element is affected by the following invariants: obs-7
      TypedateTime, boolean, string, SampledData, Quantity, Period, Ratio, integer, time, Range, CodeableConcept
      [x] NoteSeeChoice of Data Typesfor further information about how to use [x]
      Is Modifierfalse
      Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
      Must Supporttrue
      Summarytrue
      Requirements

      An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      36. Observation.value[x]:valuePeriod
      Slice NamevaluePeriod
      Definition

      The information determined as a result of making the observation, if the information has a simple value.

      ShortActual result
      Comments

      An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.

      Control0..1
      This element is affected by the following invariants: obs-7
      TypePeriod, dateTime, boolean, string, SampledData, Quantity, Ratio, integer, time, Range, CodeableConcept
      [x] NoteSeeChoice of Data Typesfor further information about how to use [x]
      Is Modifierfalse
      Must Supporttrue
      Summarytrue
      Requirements

      An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      38. Observation.value[x]:valueQuantity
      Slice NamevalueQuantity
      Definition

      A measured amount (or an amount that can potentially be measured). Note that measured amounts include amounts that are not precisely quantified, including amounts involving arbitrary units and floating currencies. This profile imposes that the code system for units be UCUM.


      The information determined as a result of making the observation, if the information has a simple value.

      ShortA measured amount using UCUMActual result
      Comments

      The context of use may frequently define what kind of quantity this is and therefore what kind of units can be used. The context of use may also restrict the values for the comparator.


      An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.

      Control0..1
      This element is affected by the following invariants: ele-1, obs-7
      TypeQuantity(Quantity (IPS)), dateTime, boolean, string, SampledData, Period, Ratio, integer, time, Range, CodeableConcept
      [x] NoteSeeChoice of Data Typesfor further information about how to use [x]
      Is Modifierfalse
      Must Supporttrue
      Requirements

      An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      qty-3: If a code for the unit is present, the system SHALL also be present (code.empty() or system.exists())
      40. Observation.value[x]:valueCodeableConcept
      Slice NamevalueCodeableConcept
      Definition

      A concept that may be defined by a formal reference to a terminology or ontology or may be provided by text.


      The information determined as a result of making the observation, if the information has a simple value.

      ShortConcept - reference to a terminology or just textActual result
      Comments

      Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.


      An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.

      Control0..1
      This element is affected by the following invariants: ele-1, obs-7
      BindingThe codes SHOULD be taken from For codes, see Results Coded Values Pathology - IPS
      (preferred to http://hl7.org/fhir/uv/ips/ValueSet/result-coded-value-pathology-uv-ips)
      TypeCodeableConcept(Codeable Concept (IPS)), dateTime, boolean, string, SampledData, Quantity, Period, Ratio, integer, time, Range
      [x] NoteSeeChoice of Data Typesfor further information about how to use [x]
      Is Modifierfalse
      Must Supporttrue
      Requirements

      An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      42. Observation.component
      Definition

      Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

      ShortComponent results
      Comments

      For a discussion on the ways Observations can be assembled in groups together see Notes below.

      Control0..*
      TypeBackboneElement
      Is Modifierfalse
      Must Supporttrue
      Summarytrue
      Requirements

      Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      44. Observation.component.modifierExtension
      Definition

      May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

      Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

      ShortExtensions that cannot be ignored even if unrecognized
      Comments

      There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

      Control0..*
      TypeExtension
      Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
      Summarytrue
      Requirements

      Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

      Alternate Namesextensions, user content, modifiers
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
      46. Observation.component.code
      Definition

      Describes what was observed. Sometimes this is called the observation "code".

      ShortType of component observation (code / type)
      Comments

      All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

      Control1..1
      BindingFor example codes, see LOINCCodeshttp://hl7.org/fhir/ValueSet/observation-codes
      (example to http://hl7.org/fhir/ValueSet/observation-codes)

      Codes identifying names of simple observations.

      TypeCodeableConcept
      Is Modifierfalse
      Summarytrue
      Requirements

      Knowing what kind of observation is being made is essential to understanding the observation.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))