CodeSystem: MissingDicomTerminology Id: codesystem-missing-dicom-terminology Title: "Missing DICOM Terminology" Description: "Code system for codes that are defined in DICOM but for which no matching code system is available in FHIR." * ^experimental = false * ^caseSensitive = true * ^hierarchyMeaning = #is-a * ^content = #fragment * #elements "DICOM Elements" "DICOM Element definitions" * #00080016 "SOP Class UID" "Uniquely identifies the SOP Class." * #00080018 "SOP Instance UID" "Uniquely identifies the SOP Instance." * #00080060 "Modality" "Type of device, process or method that originally acquired or produced the data used to create the Instances in this Series." * #00083010 "Irradiation Event UID" "Irradiation Event UID" * #00181000 "Device Serial Number" "Device Serial Number" * #00181002 "Device UID" "Unique identifier of the equipment." * #00181008 "Manufacturer Device Class UID" "Manufacturer Device Class UID" * #0020000D "Study Instance UID" "Unique identifier for the Study." * #0020000E "Series Instance UID" "Unique identifier of the Series." * #00080050 "Accession Number" "A departmental Information System generated number that identifies the Imaging Service Request." * #0040A171 "Observation UID" "Unique identifier for the observation Content Item (and its subsidiary Content Items, if any). The UID represents the semantic content of the observation; an encoding of the same observation with the same context into another representation (e.g., a CDA Entry) may use the same UID." * #00400554 "Specimen UID" "Unique identifier for the Specimen." * #00620021 "Tracking UID" "A unique identifier used for tracking a finding or feature, potentially across multiple reporting objects, over time."