Profile Comparison between http://hl7.eu/fhir/laboratory/StructureDefinition/Ratio-eu-lab vs http://hl7.eu/fhir/laboratory/StructureDefinition/Ratio-eu-lab

Left:Ratio (Eu Lab) (http://hl7.eu/fhir/laboratory/StructureDefinition/Ratio-eu-lab)
Right:Ratio (Eu Lab) (http://hl7.eu/fhir/laboratory/StructureDefinition/Ratio-eu-lab)

Messages

ErrorStructureDefinition.versionValues for version differ: '0.1.0' vs '0.2.0-ci'
InformationStructureDefinition.statusValues for status differ: 'active' vs 'draft'
InformationStructureDefinition.dateValues for date differ: '2024-02-26T08:16:21+01:00' vs '2024-10-14T12:48:35+00:00'

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.org/fhir/uv/ips/StructureDefinition/Ratio-uv-ips
      .copyrightUsed by permission of HL7 Europe, all rights reserved Creative Commons License
        .date2024-02-26T08:16:21+01:002024-10-14T12:48:35+00:00
        • Values Differ
        .descriptionThis profile constrains the Ratio data type to use UCUM as the code system for units and optionally share measurement uncertainty
          .experimental
            .fhirVersion4.0.1
              .jurisdiction
                ..jurisdiction[0]http://unstats.un.org/unsd/methods/m49/m49.htm#150
                  .kindcomplex-type
                    .nameRatioEuLab
                      .publisherHL7 Europe
                        .purposeThis profile of the Ratio data type imposes the usage of the UCUM as the code system for units and allows expressing uncertainty of measurement
                          .statusactivedraft
                          • Values Differ
                          .titleRatio (Eu Lab)
                            .typeRatio
                              .urlhttp://hl7.eu/fhir/laboratory/StructureDefinition/Ratio-eu-lab
                                .version0.1.00.2.0-ci
                                • Values Differ

                                Structure

                                NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.R TypeR Description & ConstraintsCommentsdoco
                                .. Ratio C0..*RatioIPSA measured ratio using UCUM
                                rat-1: Numerator and denominator SHALL both be present, or both are absent. If both are absent, there SHALL be some extension present
                                C0..*RatioIPSA measured ratio using UCUM
                                rat-1: Numerator and denominator SHALL both be present, or both are absent. If both are absent, there SHALL be some extension present
                                  ... id 0..1stringUnique id for inter-element referencing0..1stringUnique id for inter-element referencing
                                    ... Slices for extension 0..*ExtensionAdditional content defined by implementations
                                    Slice: Unordered, Open by value:url
                                    0..*ExtensionAdditional content defined by implementations
                                    Slice: Unordered, Open by value:url
                                      ... numerator SC0..1??A measured amount using UCUM
                                      qty-3: If a code for the unit is present, the system SHALL also be present
                                      SC0..1??A measured amount using UCUM
                                      qty-3: If a code for the unit is present, the system SHALL also be present

                                        doco Documentation for this format