HL7 Europe Laboratory Report
0.2.0-ci - ci-build 150

HL7 Europe Laboratory Report, published by HL7 Europe. This guide is not an authorized publication; it is the continuous build for version 0.2.0-ci built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7-eu/laboratory/ and changes regularly. See the Directory of published versions

Logical Model: ResultLabEhn - Detailed Descriptions

Page standards status: Informative Maturity Level: 2

Definitions for the Result logical model.

Guidance on how to interpret the contents of this table can be found here

0. Result
Definition

Results data elements. Section A5 of the eHN guideline.

ShortA.5 - Results data elements
Logical ModelInstances of this logical model are not marked to be the target of a Reference
2. Result.narrative
Definition

A.5.1 Laboratory report narrative

ShortA.5.1 Laboratory report narrative
Control0..1
TypeBackboneElement
4. Result.narrative.report
Definition

Entire report (textual summary inside the laboratory result report document) as issued by the laboratory.

ShortA.5.1.1 Narrative report
Control0..*
TypeNarrative
6. Result.narrative.notes
Definition

Comments, such as a textual interpretation or advice accompanying the result report, for example.

ShortA.5.1.2 Comments, interpretation and recommendations
Control0..*
TypeNarrative
8. Result.observation
Definition

A.5.2 Observation details (report could consist of multiple observations)

ShortA.5.2 Observation details
Control0..*
TypeBackboneElement
10. Result.observation.dateTime
Definition

Date and time of the observation - Preferred system(s): ISO 8601

ShortA.5.2.1 Observation date
Control0..*
TypeCodeableConcept
12. Result.observation.code
Definition

Code representing the observation using the agreed code systems.

  • Preferred system(s): LOINC
  • Preferred system(s): NPU
  • Preferred system(s): SNOMED CT
ShortA.5.2.3 Observation code
Control0..*
TypeCodeableConcept
14. Result.observation.code.name
Definition

Full name of the observation according to the used test coding standard.

ShortA.5.2.3.1 Observation name
Control0..*
Typestring
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
16. Result.observation.code.originalName
Definition

Original (conventional) name of the observation as used by the laboratory

ShortA.5.2.3.2 Observation original name
Control0..*
Typestring
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
18. Result.observation.code.displayName
Definition

Simplified (short name of the observation) for display.

ShortA.5.2.3.3 Observation display name
Control0..*
Typestring
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
20. Result.observation.method
Definition

Observation method (measurement principle) to obtain the result.

  • Preferred system(s): SNOMED CT
ShortA.5.2.4 Observation method
Control0..*
TypeCodeableConcept
22. Result.observation.device
Definition

Device (analyser), laboratory test kit and used calibrator information (identifier, type, name, model, manufacturer)

  • Preferred system(s): SNOMED CT
  • Preferred system(s): EMDN
ShortA.5.2.5 Observation device
Control0..*
TypeCodeableConcept
24. Result.observation.order
Definition

Identifies order and order placer this observation belongs to.

ShortA.5.2.8 Order
Control0..*
TypeBackboneElement
26. Result.observation.performer
Definition

Identifies the originator/author and provides provenance information about the source of the results data that may have not originated with the source of the whole Laboratory Report document.

ShortA.5.2.9 Performer
Control0..*
TypeBackboneElement
28. Result.observation.reporter
Definition

With certain observation results, e.g. there may also be an interpreter or a person responsible for validation.

ShortA.5.2.10 Reporter
Control0..*
TypeBackboneElement
30. Result.observation.result
Definition

Result of the observation including text, numeric and coded results of the measurement and measurement uncertainty. Content of the observation result will vary according to the type of the observation.

  • Preferred system(s): SNOMED CT (for ordinal or nominal scale results and result interpretation)
  • Preferred system(s): UCUM (for units)
ShortA.5.2.11 Observation result
Control0..*
TypeBackboneElement
32. Result.observation.interpretation
Definition

Information about reference intervals and result interpretation.

  • Preferred system(s): SNOMED CT
  • Preferred system(s): HL7 v3 Code System ObservationInterpretation
ShortA.5.2.12 Observation interpretation
Control0..*
TypeCodeableConcept
34. Result.observation.description
Definition

Comments and narrative representation of the observation result and findings.

ShortA.5.2.13 Result description
Control0..*
TypeNarrative
36. Result.observation.accreditationStatus
Definition

Accreditation status of the laboratory for the particular observation.

ShortA.5.2.14 Accreditation status
Control0..*
TypeBackboneElement