HL7 Europe Imaging Report R4, published by HL7 Europe. This guide is not an authorized publication; it is the continuous build for version 1.0.0-ballot built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7-eu/imaging-r4/ and changes regularly. See the Directory of published versions
Document Details
Language: en
Profile: Bundle: Imaging Report
Final Document at 2025-05-08 by PractitionerRole Radiologist, Organization Radiology Zentrum Bremen for Frau GuteFrage Test-Schusti(official) (no stated gender), DoB: 1976-04-29
Document Subject
Language: en
Profile: Patient (EU core)
Frau GuteFrage Test-Schusti(official) (no stated gender), DoB: 1976-04-29
Document Content
Radiology report composition narrative. See section narratives below.| ImagingStudy: | identifier = Study Instance UID: DUI#urn:oid:1.2.276.2000010.784732; status = available; modality = Magnetic Resonance; started = 2025-04-29 |
| ImagingStudy: | identifier = Study Instance UID: DUI#urn:oid:1.2.276.2000010.784733; status = available; modality = Magnetic Resonance; started = 2025-04-29 |
| Note: | Linker Fuß: Allenfalls geringe Abflachung des Fußgewölbes und normale Dicke der Plantarfaszie. Regelrechte Artikulation im Rückfuß, Mittelfuß und Vorfußes. Im Großzehengrundgelenk deutliche Verschmälerung des Gelenkspaltes und Ausbildung von subchondralen Geröllzysten sowie deutliche postoperative Veränderungen nach Umstellungsosteotomie. Die Beuge- und Strecksehnen sind intakt. |
| Note: | Rechter Fuß: Analog zur Gegenseite zeigt sich eine allenfalls geringe Abflachung des Fußgewölbes und unauffällige Plantarfaszie. Normale Artikulation im Rückfuß, Mittelfußes und Vorfußes. Im Seitenvergleich rechts geringere degenerative Veränderungen des Großzehengrundgelenkes. Keine Signalauffälligkeiten an den Beuge- und Strecksehnen. |
| Note: | Beginnende Großzehengrundgelenksarthrose, links mehr als rechts. Z.n. Umstellungsosteotomie des MFK1 links. |
Entry 2 - fullUrl = http://hl7.eu/fhir/imaging-r5/DiagnosticReport/DiagnosticReportSemiStructured
Resource DiagnosticReport:
Id: DiagnosticReportSemiStructured Code: ( http://loinc.org: 24802-1 )
Identifier: http://example.org/myhosptital/reportidentifiers: o32u4js8492ff
BasedOn: Identifier: Accession ID/123456789 Status: final Category: Radiologie ( http://terminology.hl7.org/CodeSystem/v2-0074: RAD )
( http://loinc.org: 85430-7 )
( http://hl7.eu/fhir/eu-health-data-api/CodeSystem/eehrxf-document-priority-category-cs: Medical-Imaging )
Subject: Frau GuteFrage Test-Schusti(official) (no stated gender), DoB: 1976-04-29 Period: 2025-05-08 Performer: Results Interpreter: Conclusion: Beginnende Großzehengrundgelenksarthrose, links mehr als rechts. Z.n. Umstellungsosteotomie des MFK1 links.
Presented form:
- application/pdf @ http://hl7.eu/fhir/imaging-r5/Binary/BinarySemistructuredReport
Entry 3 - fullUrl = http://hl7.eu/fhir/imaging-r5/Patient/PatientSemiStructuredReport
Resource Patient:
Language: en
Profile: Patient (EU core)
Frau GuteFrage Test-Schusti(official) (no stated gender), DoB: 1976-04-29
Entry 4 - fullUrl = http://hl7.eu/fhir/imaging-r5/ImagingStudy/ImagingStudySemiStructuredReport1
Resource ImagingStudy:
Language: en
Profile: ImagingStudy: General
Extension: Anatomical Region: Lower extremity
identifier: Study Instance UID/urn:oid:1.2.276.2000010.784732
status: Available
modality: Magnetic Resonance
subject: Frau GuteFrage Test-Schusti(official) (no stated gender), DoB: 1976-04-29
started: 2025-04-29
basedOn: Identifier: Accession ID/123456789
series
uid: 1.2.276.2000010.784732.1
number: 1
modality: Magnetic Resonance
description: PD FatSat 3D (1.0mm) sagittal
bodySite: No display for ImagingStudy.series.bodySite (concept: Entire left foot (body structure))
laterality: Left lateral
performer
function: custodian
performer
function: location
Entry 5 - fullUrl = http://hl7.eu/fhir/imaging-r5/ImagingStudy/ImagingStudySemiStructuredReport2
Resource ImagingStudy:
Language: en
Profile: ImagingStudy: General
Extension: Anatomical Region: Lower extremity
identifier: Study Instance UID/urn:oid:1.2.276.2000010.784733
status: Available
modality: Magnetic Resonance
subject: Frau GuteFrage Test-Schusti(official) (no stated gender), DoB: 1976-04-29
started: 2025-04-29
basedOn: Identifier: Accession ID/123456789
series
uid: 1.2.276.2000010.784733.1
number: 1
modality: Magnetic Resonance
description: PD FatSat 3D (1.0mm) sagittal
bodySite: No display for ImagingStudy.series.bodySite (concept: Entire right foot (body structure))
laterality: Left lateral
performer
function: custodian
performer
function: location
series
uid: 1.2.276.2000010.784733.2
number: 2
modality: Magnetic Resonance
description: T1 (2.5mm) axial
bodySite: No display for ImagingStudy.series.bodySite (concept: Entire right foot (body structure))
laterality: Right lateral
performer
function: custodian
performer
function: location
Entry 6 - fullUrl = http://hl7.eu/fhir/imaging-r5/PractitionerRole/PractitionerRoleSemiStructuredReportAuthor
Resource PractitionerRole:
Language: en
Profile: PractitionerRole (EU core)
practitioner: Practitioner Dr. Lucas Gasenzer(official)
organization: Organization Radiology Zentrum Bremen
code: Radiologist
Entry 7 - fullUrl = http://hl7.eu/fhir/imaging-r5/Organization/OrganizationSemiStructuredReport
Resource Organization:
Language: en
Profile: Organization (EU core)
name: Radiology Zentrum Bremen
Contacts
Telecom Address +49 421 1234567 Schwachhauser Heerstraße 54 Bremen 28209 Germany (work)
Entry 8 - fullUrl = http://hl7.eu/fhir/imaging-r5/Binary/BinarySemistructuredReport
Resource Binary:
Language: en
contentType: application/pdf
data: (base64 data - 263,952 base64 chars)