Generated Mon Apr 07 08:03:27 UTC 2025, FHIR version 4.0.1 for hl7.fhir.eu.base.r4#0.0.1 (canonical = http://hl7.eu/fhir/base (history)). See Full QA Report & IP
Quality Checks | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Publisher Version: | IG Publisher Version: v1.8.23 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Publication Code: | n/a . PackageId = hl7.fhir.eu.base.r4, Canonical = http://hl7.eu/fhir/base | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Realm Check for n/a: |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Language Info: | This IG has no language information | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Publication Request: |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Supressed Messages: | 40 Suppressed Issues | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Dependency Checks: |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Related IGs: | n/a | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Dependent IGs: | no references | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Global Profiles: | (none declared) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Terminology Server(s): | http://tx.fhir.org/r4 (details) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
HTA Analysis: | All OK | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
R5 Dependencies: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Draft Dependencies: |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Modifier Extensions: | (none) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Previous Version Comparison: | Unable to compare with previous version: Unable to find version history at http://hl7.eu/fhir/base (Problem #1 with package-list.json at http://hl7.eu/fhir/base: Not Found) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
IPA Comparison: | n/a | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
IPS Comparison: | n/a | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Validation Flags: | On: autoLoad; Off: hintAboutNonMustSupport, anyExtensionsAllowed, checkAggregation, showReferenceMessages, noExperimentalContent, displayWarnings | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Summary: | errors = 2, warn = 1, info = 3, broken links = 0, pinned = n/a. |
Filename | Errors | Warnings | Hints |
Build Errors | 1 | 0 | 0 |
/scratch/repo/fsh-generated/resources/ImplementationGuide-hl7.fhir.eu.base.r4 | 0 | 1 | 0 |
/scratch/repo/fsh-generated/resources/ValueSet-iso-ehicCountryCode | 1 | 0 | 0 |
error | There is no jira specification file defined with the expected name of FHIR-eu-base.r4 in the xml folder of the https://github.com/HL7/Jira-Spec-Artifacts project. This must exist before ballot or publication. |
Path | Severity | Message |
ImplementationGuide.dependsOn[3].uri (l1/c2519) | warning | Canonical URL 'http://fhir.org/packages/hl7.fhir.eu.extensions/ImplementationGuide/hl7.fhir.eu.extensions' does not resolve TYPE_SPECIFIC_CHECKS_DT_CANONICAL_RESOLVE |
Path | Severity | Message |
ValueSet.compose.include[0].concept[31] (l1/c3613) | error | The code 'UK' is not valid in the system urn:iso:std:iso:3166 (Unknown code 'UK' in the CodeSystem 'urn:iso:std:iso:3166' version '2018') Editor's Comment: UK is a reserved code in iso:3166 see https://www.iso.org/obp/ui/#iso:code:3166:UK (Reserved codes – codes that do not represent a country name in the standard but that have been reserved for a certain use.). In tis case UK is used to identify the United Kingdom for the EHIC. VALUESET_INCLUDE_INVALID_CONCEPT_CODE |
Suppressed Messages (Warnings, hints, broken links)
Deprecated artefcats
Known issue with BodyStructure extensions (see https://chat.fhir.org/#narrow/channel/179252-IG-creation/topic/Issue.20with.20the.20bodySite.20extension)
Multiple extension versions
Not found Code System
Not recognized system
Not resolvable URL
Reference to deprecated ValueSet
SNOMED CT related warnings
The EHIC patient example is contained in the EHIC Coverage example
UK is a reserved code in iso:3166 see https://www.iso.org/obp/ui/#iso:code:3166:UK (Reserved codes – codes that do not represent a country name in the standard but that have been reserved for a certain use.). In tis case UK is used to identify the United Kingdom for the EHIC.
duplicate anchor Ids
experimental value set
Errors sorted by type
fsh-generated/resources/Coverage-EhicExampleIt.json | Reference to experimental CodeSystem http://terminology.hl7.eu/CodeSystem/v3-ActCode|0.0.1 |
fsh-generated/resources/StructureDefinition-Coverage-eu-ehic.json | Reference to experimental CodeSystem http://terminology.hl7.eu/CodeSystem/v3-ActCode|0.0.1 |
fsh-generated/resources/StructureDefinition-Coverage-eu-ehic.json | Reference to experimental CodeSystem http://terminology.hl7.eu/CodeSystem/v3-ActCode|0.0.1 |
fsh-generated/resources/ImplementationGuide-hl7.fhir.eu.base.r4.json | Canonical URL 'http://fhir.org/packages/hl7.fhir.eu.extensions/ImplementationGuide/hl7.fhir.eu.extensions' does not resolve |
fsh-generated/resources/ValueSet-iso-ehicCountryCode.json | The code 'UK' is not valid in the system urn:iso:std:iso:3166 (Unknown code 'UK' in the CodeSystem 'urn:iso:std:iso:3166' version '2018') |