eReferral Implementation Guide, published by Riziv-Inami Platform. This guide is not an authorized publication; it is the continuous build for version 3.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7-be/referral-uhmep/ and changes regularly. See the Directory of published versions
Examination to confirm: Business Data has no narrative for this test. Technical Data gives Other (74964007), which is not in the local required imaging ValueSet, and a free-text preference for CT. Confirm a specific examination and its permitted SNOMED code. The template is not a validated positive test until this is resolved.
POST /ServiceRequest
Profile: ereferral-servicerequest-diagnosticimaging.
The physician completes imaging safety screening and creates the prescription. Age and sex at birth remain visible as business values, while the contained patient carries encrypted values. Safety answers not supplied by the scenario are runtime inputs, not assumed negative findings. Complete and review them before submitting the completed questionnaire.
| Business Field | Value |
|---|---|
| Patient age | 52 years |
| Sex at birth | Female |
| Examination | CT examination: anatomy and protocol to be confirmed |
| Clinical indications | Flank pain with suspected recurrent stone disease |
| Clinical context | A fifty-two-year-old woman has flank pain with suspected recurrent stone disease. The workbook mentions a CT examination as the preferred alternative but does not specify the examination anatomy or protocol. |
| Patient | Patient pseudonym: {{SEC1}} / {{transitInfo}} |
| Requester | Physician, SSIN {{prescriberSsin}} |
| Creation date | {{createdAt}} |
| Validity start | {{validityStartDate}} |
| Priority | {{imagingPriority}} |
| Care setting | {{careTrack}} |
| Diabetes | {{hasDiabetes}} |
| Contrast-agent allergy | {{hasContrastAllergy}} |
| Metallic debris | {{hasMetallicDebris}} |
| Renal dysfunction | {{hasRenalDysfunction}} |
| No imaging attention condition | {{noAttentionCondition}} |
| Business Field | FHIR Field | FHIR JSON |
|---|---|---|
| Imaging discipline, prescription type and care setting | ServiceRequest.category | |
| Examination and protocol | ServiceRequest.code | |
| Patient age and sex at birth (encrypted) | ServiceRequest.contained (Patient) | |
| Patient reference and pseudonym | ServiceRequest.subject | |
| Imaging safety screening | ServiceRequest.contained (QuestionnaireResponse) | |
| Clinical indications and checklist reference | ServiceRequest.supportingInfo | |
| Clinical context | ServiceRequest.reasonCode | |
| Requester | ServiceRequest.requester | |
| Validity start | ServiceRequest.extension (be-ext-validity-period) | |
| Priority | ServiceRequest.priority | |
| Creation date | ServiceRequest.authoredOn | |
{
"resourceType": "ServiceRequest",
"meta": {
"profile": [
"https://www.riziv-inami.be/standards/fhir/ereferral/StructureDefinition/ereferral-servicerequest-diagnosticimaging"
],
"extension": [
{
"id": "{{kid}}",
"url": "https://www.ehealth.fgov.be/standards/fhir/infsec/StructureDefinition/be-ext-key-pseudonymization",
"extension": [
{
"url": "key",
"valueString": "urn:be:fgov:pseudo:v2:{{SEC1}}:{{transitInfo}}",
"_valueString": {
"extension": [
{
"url": "https://www.ehealth.fgov.be/standards/fhir/infsec/StructureDefinition/be-ext-pseudonymization",
"extension": [
{
"url": "marker",
"valueBoolean": true
},
{
"url": "format",
"valueCode": "direct"
},
{
"url": "version",
"valuePositiveInt": 2
}
]
}
]
}
}
]
}
]
},
"contained": [
{
"resourceType": "Patient",
"id": "patient",
"meta": {
"profile": [
"https://www.ehealth.fgov.be/standards/fhir/core/StructureDefinition/be-patient|2.2.0"
]
},
"extension": [
{
"url": "https://www.ehealth.fgov.be/standards/fhir/core/StructureDefinition/be-ext-gender-at-birth",
"valueCodeableConcept": {
"coding": [
{
"system": "http://hl7.org/fhir/administrative-gender",
"code": "other"
}
],
"extension": [
{
"url": "https://www.ehealth.fgov.be/standards/fhir/infsec/StructureDefinition/be-ext-pseudonymized-content",
"extension": [
{
"url": "encryptedValue",
"valueString": "urn:be:fgov:pseudo-encrypted:v1:{{kid}}:{{sexAtBirthJwe}}"
},
{
"url": "marker",
"valueBoolean": true
},
{
"url": "format",
"valueCode": "encrypted"
},
{
"url": "version",
"valuePositiveInt": 1
}
]
}
]
}
}
],
"_birthDate": {
"extension": [
{
"url": "https://www.ehealth.fgov.be/standards/fhir/infsec/StructureDefinition/be-ext-pseudonymized-content",
"extension": [
{
"url": "encryptedValue",
"valueString": "urn:be:fgov:pseudo-encrypted:v1:{{kid}}:{{birthDateJwe}}"
},
{
"url": "marker",
"valueBoolean": true
},
{
"url": "format",
"valueCode": "encrypted"
},
{
"url": "version",
"valuePositiveInt": 1
}
]
}
]
}
},
{
"resourceType": "QuestionnaireResponse",
"id": "safety-checklist",
"meta": {
"profile": [
"https://www.riziv-inami.be/standards/fhir/ereferral/StructureDefinition/ereferral-imaging-attention-conditions-response"
]
},
"questionnaire": "https://www.ehealth.fgov.be/standards/fhir/drp/Questionnaire/be-questionnaire-imaging-attention-conditions",
"status": "completed",
"authored": "{{createdAt}}",
"item": [
{
"linkId": "diabetes",
"answer": [
{
"valueBoolean": "{{hasDiabetes}}"
}
]
},
{
"linkId": "allergy-contrast-agent",
"answer": [
{
"valueBoolean": "{{hasContrastAllergy}}"
}
]
},
{
"linkId": "metallic-debris",
"answer": [
{
"valueBoolean": "{{hasMetallicDebris}}"
}
]
},
{
"linkId": "renal-dysfunction",
"answer": [
{
"valueBoolean": "{{hasRenalDysfunction}}"
}
]
},
{
"linkId": "none",
"answer": [
{
"valueBoolean": "{{noAttentionCondition}}"
}
]
}
]
}
],
"extension": [
{
"url": "https://www.ehealth.fgov.be/standards/fhir/drp/StructureDefinition/be-ext-validity-period",
"valuePeriod": {
"start": "{{validityStartDate}}"
}
}
],
"status": "active",
"intent": "order",
"priority": "{{imagingPriority}}",
"category": [
{
"coding": [
{
"system": "http://snomed.info/sct",
"code": "363679005"
}
]
},
{
"coding": [
{
"system": "https://www.ehealth.fgov.be/standards/fhir/terminology/CodeSystem/be-cs-prescription-type",
"code": "diagnostic-imaging-appendix-82"
}
]
},
{
"coding": [
{
"system": "https://www.ehealth.fgov.be/standards/fhir/terminology/CodeSystem/be-cs-request-track",
"code": "{{careTrack}}"
}
]
}
],
"code": {
"coding": [
{
"system": "http://snomed.info/sct",
"code": "{{selectedImagingCode}}"
}
],
"text": "urn:be:fgov:pseudo-encrypted:v1:{{kid}}:{{imagingDescriptionJwe}}",
"_text": {
"extension": [
{
"url": "https://www.ehealth.fgov.be/standards/fhir/infsec/StructureDefinition/be-ext-pseudonymization",
"extension": [
{
"url": "marker",
"valueBoolean": true
},
{
"url": "format",
"valueCode": "encrypted"
},
{
"url": "version",
"valuePositiveInt": 1
}
]
}
]
}
},
"subject": {
"identifier": {
"use": "official",
"system": "https://www.ehealth.fgov.be/standards/fhir/core/NamingSystem/ssin",
"value": "urn:be:fgov:pseudo:v2:{{SEC1}}:{{transitInfo}}",
"_value": {
"extension": [
{
"url": "https://www.ehealth.fgov.be/standards/fhir/infsec/StructureDefinition/be-ext-pseudonymization",
"extension": [
{
"url": "marker",
"valueBoolean": true
},
{
"url": "format",
"valueCode": "direct"
},
{
"url": "version",
"valuePositiveInt": 2
}
]
}
]
}
},
"reference": "#patient"
},
"authoredOn": "{{createdAt}}",
"requester": {
"reference": "PractitionerRole/{{prescriberSsin}}-PHYSICIAN"
},
"reasonCode": [
{
"text": "urn:be:fgov:pseudo-encrypted:v1:{{kid}}:{{clinicalContextJwe}}",
"_text": {
"extension": [
{
"url": "https://www.ehealth.fgov.be/standards/fhir/infsec/StructureDefinition/be-ext-pseudonymization",
"extension": [
{
"url": "marker",
"valueBoolean": true
},
{
"url": "format",
"valueCode": "encrypted"
},
{
"url": "version",
"valuePositiveInt": 1
}
]
}
]
}
}
],
"supportingInfo": [
{
"reference": "#safety-checklist",
"extension": [
{
"url": "https://www.ehealth.fgov.be/standards/fhir/drp/StructureDefinition/be-ext-radiology-supporting-info-role",
"valueCode": "safety-checklist"
}
]
},
{
"display": "Patient condition",
"extension": [
{
"url": "https://www.ehealth.fgov.be/standards/fhir/drp/StructureDefinition/be-ext-radiology-supporting-info-role",
"valueCode": "patient-condition"
},
{
"url": "https://www.ehealth.fgov.be/standards/fhir/drp/StructureDefinition/be-ext-codeable-concept",
"valueCodeableConcept": {
"text": "urn:be:fgov:pseudo-encrypted:v1:{{kid}}:{{indication1Jwe}}",
"_text": {
"extension": [
{
"url": "https://www.ehealth.fgov.be/standards/fhir/infsec/StructureDefinition/be-ext-pseudonymization",
"extension": [
{
"url": "marker",
"valueBoolean": true
},
{
"url": "format",
"valueCode": "encrypted"
},
{
"url": "version",
"valuePositiveInt": 1
}
]
}
]
}
}
}
]
}
]
}