HL7 v2.9 Vocabulary, published by HL7/FO. This guide is not an authorized publication; it is the continuous build for version 0.2.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/frankoemig/hl7.v2.terminology.v29/ and changes regularly. See the Directory of published versions

ValueSet: Specimen Role (2.9 - 1.2.0) (Experimental)

Official URL: http://terminology.hl7.org/v2plusvocab/ValueSet/hl7VSspecimenRole Version: 1.2.0
Active as of 2026-03-13 Computable Name: Hl7VSspecimenRole
Other Identifiers: OID:2.16.840.1.113883.21.243, urn:ietf:rfc:3986#Uniform Resource Identifier (URI)#http://terminology.hl7.org/v2plusvocab/ValueSet/v2-0369

Copyright/Legal: HL7 Inc., 2026

Value Set of codes that identify the role of a sample.

References

This value set is not used here; it may be used elsewhere (e.g. specifications and/or implementations that use this content)

Logical Definition (CLD)

 

Expansion

Expansion performed internally based on codesystem Specimen Role (2.9 - 1.2.0) v1.2.0 (CodeSystem)

This value set contains 12 concepts

SystemCodeDisplay (en)DefinitionJSONXML
http://terminology.hl7.org/v2plusvocab/CodeSystem/specimenRole  BBlind SampleUsed to test the validity of the measurement process, where the composition of the sample is unknown except to the person submitting it.
http://terminology.hl7.org/v2plusvocab/CodeSystem/specimenRole  CCalibratorUsed for initial setting of calibration of the instrument.
http://terminology.hl7.org/v2plusvocab/CodeSystem/specimenRole  EElectronic QCUsed with manufactured reference providing signals that simulate QC results
http://terminology.hl7.org/v2plusvocab/CodeSystem/specimenRole  FFiller Organization ProficiencySpecimen used for testing proficiency of the organization performing the testing (Filler).
http://terminology.hl7.org/v2plusvocab/CodeSystem/specimenRole  GGroupUsed when solid specimens consist of multiple individual elements that are not individually identified but can be separated again into the original specimens. The identifiers of the original specimens may be tracked.
http://terminology.hl7.org/v2plusvocab/CodeSystem/specimenRole  HHistorical SpecimenThis identifies a parent specimen to the specimen that is submitted for testing
http://terminology.hl7.org/v2plusvocab/CodeSystem/specimenRole  LPoolUsed when aliquots of liquid individual specimens are combined to form a single specimen representing all of the components that are not individually identified. The identifiers of the original specimens may be tracked.
http://terminology.hl7.org/v2plusvocab/CodeSystem/specimenRole  OOperator ProficiencySpecimen used for testing Operator Proficiency.
http://terminology.hl7.org/v2plusvocab/CodeSystem/specimenRole  PPatientUsed for any patient sample.
http://terminology.hl7.org/v2plusvocab/CodeSystem/specimenRole  QControl specimenUsed when specimen is the control specimen (either positive or negative).
http://terminology.hl7.org/v2plusvocab/CodeSystem/specimenRole  RReplicateUsed when a patient sample is re-run as a control for a repeat test.
http://terminology.hl7.org/v2plusvocab/CodeSystem/specimenRole  VVerifying CalibratorUsed for periodic calibration checks.

Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code