International Patient Summary Implementation Guide
2.0.0 - STU 2 International flag

International Patient Summary Implementation Guide, published by HL7 International / Patient Care. This guide is not an authorized publication; it is the continuous build for version 2.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/costateixeira/fhir-ips/ and changes regularly. See the Directory of published versions

Logical Model: MedicalDevicesSection - Detailed Descriptions

Page standards status: Trial-use Maturity Level: 2

Definitions for the MedicalDevicesSection logical model.

Guidance on how to interpret the contents of this table can be found here

0. MedicalDevicesSection
Definition

Medical Devices Section

ShortMedical Devices
Control0..*
Is Modifierfalse
Logical ModelInstances of this logical model are not marked to be the target of a Reference
2. MedicalDevicesSection.contentStatus
Definition

Device content status

ShortDevice content status
Comments

Conditional

Control0..1
TypeCodeableConcept
4. MedicalDevicesSection.device
Definition

Device

ShortDevice
Control0..*
TypeBackboneElement
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
6. MedicalDevicesSection.device.id
Definition

Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

ShortUnique id for inter-element referencing
Control0..1
Typestring
Is Modifierfalse
XML FormatIn the XML format, this property is represented as an attribute.
Summaryfalse
8. MedicalDevicesSection.device.extension
Definition

May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

ShortAdditional content defined by implementations
Comments

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

Control0..*
TypeExtension
Is Modifierfalse
Summaryfalse
Alternate Namesextensions, user content
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
SlicingThis element introduces a set of slices on MedicalDevicesSection.device.extension. The slices areUnordered and Open, and can be differentiated using the following discriminators:
  • value @ url
  • 10. MedicalDevicesSection.device.modifierExtension
    Definition

    May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

    Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

    ShortExtensions that cannot be ignored even if unrecognized
    Comments

    There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

    Control0..*
    TypeExtension
    Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
    Summarytrue
    Requirements

    Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

    Alternate Namesextensions, user content, modifiers
    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
    12. MedicalDevicesSection.device.type
    Definition

    Device type

    ShortDevice type
    Comments

    Required (Exceptions allowed)

    Control0..1
    TypeCodeableConcept
    14. MedicalDevicesSection.device.identifier
    Definition

    Device identifier

    ShortDevice identifier
    Comments

    Required if known

    NoteThis is a business identifier, not a resource identifier (see discussion)
    Control0..1
    TypeIdentifier
    16. MedicalDevicesSection.device.useStartDate
    Definition

    Use start date

    ShortUse start date
    Comments

    Required (Exceptions allowed)

    Control0..1
    TypedateTime
    Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
    18. MedicalDevicesSection.device.useEndDate
    Definition

    Use end date

    ShortUse end date
    Comments

    Optional

    Control0..1
    TypedateTime
    Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
    20. MedicalDevicesSection.device.careAndRisks
    Definition

    Care and risks

    ShortCare and risks
    Comments

    Required if known

    Control0..1
    TypeCodeableConcept

    Guidance on how to interpret the contents of this table can be found here

    0. MedicalDevicesSection
    Definition

    Medical Devices Section

    ShortMedical Devices
    Logical ModelInstances of this logical model are not marked to be the target of a Reference
    2. MedicalDevicesSection.contentStatus
    Definition

    Device content status

    ShortDevice content status
    Comments

    Conditional

    Control0..1
    TypeCodeableConcept
    4. MedicalDevicesSection.device
    Definition

    Device

    ShortDevice
    Control0..*
    TypeBackboneElement
    6. MedicalDevicesSection.device.type
    Definition

    Device type

    ShortDevice type
    Comments

    Required (Exceptions allowed)

    Control0..1
    TypeCodeableConcept
    8. MedicalDevicesSection.device.identifier
    Definition

    Device identifier

    ShortDevice identifier
    Comments

    Required if known

    NoteThis is a business identifier, not a resource identifier (see discussion)
    Control0..1
    TypeIdentifier
    10. MedicalDevicesSection.device.useStartDate
    Definition

    Use start date

    ShortUse start date
    Comments

    Required (Exceptions allowed)

    Control0..1
    TypedateTime
    Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
    12. MedicalDevicesSection.device.useEndDate
    Definition

    Use end date

    ShortUse end date
    Comments

    Optional

    Control0..1
    TypedateTime
    Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
    14. MedicalDevicesSection.device.careAndRisks
    Definition

    Care and risks

    ShortCare and risks
    Comments

    Required if known

    Control0..1
    TypeCodeableConcept

    Guidance on how to interpret the contents of this table can be found here

    0. MedicalDevicesSection
    Definition

    Medical Devices Section

    ShortMedical Devices
    Control0..*
    Is Modifierfalse
    Logical ModelInstances of this logical model are not marked to be the target of a Reference
    2. MedicalDevicesSection.contentStatus
    Definition

    Device content status

    ShortDevice content status
    Comments

    Conditional

    Control0..1
    TypeCodeableConcept
    4. MedicalDevicesSection.device
    Definition

    Device

    ShortDevice
    Control0..*
    TypeBackboneElement
    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    6. MedicalDevicesSection.device.id
    Definition

    Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

    ShortUnique id for inter-element referencing
    Control0..1
    Typestring
    Is Modifierfalse
    XML FormatIn the XML format, this property is represented as an attribute.
    Summaryfalse
    8. MedicalDevicesSection.device.extension
    Definition

    May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

    ShortAdditional content defined by implementations
    Comments

    There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

    Control0..*
    TypeExtension
    Is Modifierfalse
    Summaryfalse
    Alternate Namesextensions, user content
    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
    SlicingThis element introduces a set of slices on MedicalDevicesSection.device.extension. The slices areUnordered and Open, and can be differentiated using the following discriminators:
    • value @ url
    • 10. MedicalDevicesSection.device.modifierExtension
      Definition

      May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

      Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

      ShortExtensions that cannot be ignored even if unrecognized
      Comments

      There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

      Control0..*
      TypeExtension
      Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
      Summarytrue
      Requirements

      Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

      Alternate Namesextensions, user content, modifiers
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
      12. MedicalDevicesSection.device.type
      Definition

      Device type

      ShortDevice type
      Comments

      Required (Exceptions allowed)

      Control0..1
      TypeCodeableConcept
      14. MedicalDevicesSection.device.identifier
      Definition

      Device identifier

      ShortDevice identifier
      Comments

      Required if known

      NoteThis is a business identifier, not a resource identifier (see discussion)
      Control0..1
      TypeIdentifier
      16. MedicalDevicesSection.device.useStartDate
      Definition

      Use start date

      ShortUse start date
      Comments

      Required (Exceptions allowed)

      Control0..1
      TypedateTime
      Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
      18. MedicalDevicesSection.device.useEndDate
      Definition

      Use end date

      ShortUse end date
      Comments

      Optional

      Control0..1
      TypedateTime
      Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
      20. MedicalDevicesSection.device.careAndRisks
      Definition

      Care and risks

      ShortCare and risks
      Comments

      Required if known

      Control0..1
      TypeCodeableConcept