Health eData 1 Sandbox
0.1.0 - CI Build United States of America flag

Health eData 1 Sandbox, published by HL7 International / Cross-Group Projects. This guide is not an authorized publication; it is the continuous build for version 0.1.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/argonautproject/USCDIV7/ and changes regularly. See the Directory of published versions

: WADO-RS Imaging Endpoint Example - JSON Representation

Raw json | Download

{
  "resourceType" : "Endpoint",
  "id" : "wado-rs",
  "meta" : {
    "extension" : [
      {
        "url" : "http://hl7.org/fhir/StructureDefinition/instance-name",
        "valueString" : "WADO-RS Imaging Endpoint Example"
      },
      {
        "url" : "http://hl7.org/fhir/StructureDefinition/instance-description",
        "valueMarkdown" : "This WADO-RS Endpoint example provides the DICOMweb retrieve base URL used by US Core ImagingStudy examples to access study images."
      }
    ]
  },
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: Endpoint wado-rs</b></p><a name=\"wado-rs\"> </a><a name=\"hcwado-rs\"> </a><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\"/></div><p style=\"border: 1px #661aff solid; background-color: #e6e6ff; padding: 10px;\">Acme Radiology DICOMweb WADO-RS (DICOM WADO-RS (Endpoint Connection Type#dicom-wado-rs)): https://pacs.example.org/wado-rs</p><hr/><table class=\"grid\"><tr><td style=\"background-color: #f3f5da\" title=\"The status of the endpoint\">Status:</td><td colspan=\"3\">Active</td></tr><tr><td style=\"background-color: #f3f5da\" title=\"The technical base address for connecting to this endpoint\">Address:</td><td colspan=\"3\"><a href=\"https://pacs.example.org/wado-rs\">https://pacs.example.org/wado-rs</a></td></tr><tr><td style=\"background-color: #f3f5da\" title=\"The protocol, profile or standard used to connect to the endpoint\">Connection Type:</td><td colspan=\"3\"><a href=\"http://terminology.hl7.org/7.4.0/CodeSystem-endpoint-connection-type.html#endpoint-connection-type-dicom-wado-rs\">Endpoint Connection Type: dicom-wado-rs</a> (DICOM WADO-RS)</td></tr><tr><td style=\"background-color: #f3f5da\" title=\"The type of content that may be used at this endpoint\">Payload Type:</td><td colspan=\"3\"><span title=\"Codes:{http://terminology.hl7.org/CodeSystem/endpoint-payload-type any}\">Any</span></td></tr><tr><td style=\"background-color: #f3f5da\" title=\"The mime types that can be sent to and/or received from the endpoint\">Mime Type:</td><td colspan=\"3\">application/dicom</td></tr></table></div>"
  },
  "status" : "active",
  "connectionType" : {
    "system" : "http://terminology.hl7.org/CodeSystem/endpoint-connection-type",
    "code" : "dicom-wado-rs",
    "display" : "DICOM WADO-RS"
  },
  "name" : "Acme Radiology DICOMweb WADO-RS",
  "payloadType" : [
    {
      "coding" : [
        {
          "system" : "http://terminology.hl7.org/CodeSystem/endpoint-payload-type",
          "code" : "any",
          "display" : "Any"
        }
      ]
    }
  ],
  "payloadMimeType" : [
    "application/dicom"
  ],
  "address" : "https://pacs.example.org/wado-rs"
}