{
  "resourceType": "Device",
  "id": "example-mes-fr-phd-device-001",
  "meta": {
    "profile": [
      "http://hl7.org/fhir/uv/phd/StructureDefinition/PhdDevice"
    ]
  },
  "identifier": [
    {
      "system": "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680",
      "type": {
        "coding": [
          {
            "system": "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers",
            "code": "SYSID"
          }
        ]
      },
      "value": "74-E8-FF-FE-FF-05-1C-00"
    },
    {
      "type": {
        "coding": [
          {
            "system": "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers",
            "code": "BTMAC"
          }
        ]
      },
      "system": "http://hl7.org/fhir/sid/eui-48/bluetooth",
      "value": "00-1C-05-FF-E8-74"
    }
  ],
  "type": {
    "coding": [
      {
        "system": "urn:iso:std:iso:11073:10101",
        "code": "65573"
      }
    ],
    "text": "MDC_MOC_VMS_MDS_SIMP"
  },
  "specialization": [
    {
      "systemType": {
        "coding": [
          {
            "system": "urn:iso:std:iso:11073:10101",
            "code": "528388"
          }
        ],
        "text": "MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter"
      },
      "version": "1"
    }
  ],
  "version": [
    {
      "type": {
        "coding": [
          {
            "system": "urn:iso:std:iso:11073:10101",
            "code": "531976"
          }
        ],
        "text": "MDC_ID_PROD_SPEC_FW: Firmware revision"
      },
      "value": "r2.1"
    },
    {
      "type": {
        "coding": [
          {
            "system": "urn:iso:std:iso:11073:10101",
            "code": "531975"
          }
        ],
        "text": "MDC_ID_PROD_SPEC_SW: Software revision"
      },
      "value": "r1.5 9.7"
    },
    {
      "type": {
        "coding": [
          {
            "system": "urn:iso:std:iso:11073:10101",
            "code": "531974"
          }
        ],
        "text": "MDC_ID_PROD_SPEC_HW: Hardware revision"
      },
      "value": "r1.0"
    },
    {
      "type": {
        "coding": [
          {
            "system": "urn:iso:std:iso:11073:10101",
            "code": "532352"
          }
        ],
        "text": "MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version"
      },
      "value": "6.0"
    }
  ],
  "manufacturer": "Nonin_Medical_Inc.",
  "serialNumber": "501900083",
  "modelNumber": "Model 3230",
  "property": [
    {
      "type": {
        "coding": [
          {
            "code": "532353",
            "system": "urn:iso:std:iso:11073:10101"
          }
        ],
        "text": "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: certified device list as transport-specialization combo"
      },
      "valueCode": [
        {
          "coding": [
            {
              "code": "32772",
              "system": "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD"
            }
          ]
        }
      ]
    },
    {
      "type": {
        "coding": [
          {
            "code": "532354.0",
            "system": "http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"
          }
        ],
        "text": "regulation-status"
      },
      "valueCode": [
        {
          "coding": [
            {
              "code": "N",
              "system": "http://terminology.hl7.org/CodeSystem/v2-0136"
            }
          ],
          "text": "Device is Regulated"
        }
      ]
    },
    {
      "type": {
        "coding": [
          {
            "code": "68220",
            "system": "urn:iso:std:iso:11073:10101"
          }
        ],
        "text": "MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"
      },
      "valueCode": [
        {
          "coding": [
            {
              "code": "532224",
              "system": "urn:iso:std:iso:11073:10101"
            }
          ],
          "text": "MDC_TIME_SYNC_NONE:"
        }
      ]
    }
  ]
}
