EHDS Logical Information Models
0.2.0 - ci-build
EHDS Logical Information Models, published by Xt-EHR. This guide is not an authorized publication; it is the continuous build for version 0.2.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/Xt-EHR/xt-ehr-common/ and changes regularly. See the Directory of published versions
Official URL: https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSImagingStudy | Version: 0.2.0 | |||
Draft as of 2025-09-24 | Computable Name: EHDSImagingStudy |
Imaging study model includes the key information about the content of an imaging study. It does not include image pixels but includes location pointers to its image content and organises this information according to the well-established model of an imaging study made of one or more series and each series made of instances or images. Composed of a set of data (DICOM KOS) that facilitates the location of all available images.
Usages:
You can also check for usages in the FHIR IG Statistics
Description of Profiles, Differentials, Snapshots and how the different presentations work.
Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
---|---|---|---|---|
![]() ![]() |
0..* | EHDSDataSet | Elements defined in Ancestors:header Imaging study model Instances of this logical model can be the target of a Reference | |
![]() ![]() ![]() |
1..1 | Base | Common header for all patient-related data | |
![]() ![]() ![]() ![]() |
1..1 | EHDSPatient | Patient/subject information | |
![]() ![]() ![]() ![]() |
1..* | Identifier | Identifiers for the Imaging Study such as DICOM Study Instance UID. If one or more series elements are present in the ImagingStudy, then there shall be one DICOM Study UID identifier. | |
![]() ![]() ![]() ![]() |
1..* | Base | Resource authoring details | |
![]() ![]() ![]() ![]() ![]() |
1..1 | Author(s) by whom the resource was/were authored. Multiple authors could be provided. | ||
![]() ![]() ![]() ![]() ![]() ![]() |
EHDSHealthProfessional | |||
![]() ![]() ![]() ![]() ![]() ![]() |
EHDSOrganisation | |||
![]() ![]() ![]() ![]() ![]() ![]() |
EHDSDevice | |||
![]() ![]() ![]() ![]() ![]() |
1..1 | dateTime | Date and time of authoring/issuing | |
![]() ![]() ![]() ![]() |
0..1 | dateTime | Date and time of the last update to the resource (may be used for technical corrections). | |
![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Status of the resource or document | |
![]() ![]() ![]() ![]() |
0..1 | Reason for the current status of the resource. | ||
![]() ![]() ![]() ![]() ![]() |
CodeableConcept | |||
![]() ![]() ![]() ![]() ![]() |
string | |||
![]() ![]() ![]() ![]() |
0..1 | CodeableConcept | Language in which the resource is written. Language is expressed by the IETF language tag. Binding Description: (preferred): BCP 47 | |
![]() ![]() ![]() |
0..* | CodeableConcept | All of the distinct values for series' modalities Binding Description: (preferred): DICOM CID029 | |
![]() ![]() ![]() |
0..1 | EHDSEncounter | Reference to the encounter with which this imaging study is associated | |
![]() ![]() ![]() |
0..1 | dateTime | Date and time the study started. | |
![]() ![]() ![]() |
0..* | EHDSServiceRequest | References to the diagnostic requests that resulted in this imaging study being performed. | |
![]() ![]() ![]() |
0..1 | integer | Number of Series in the Study. This value given may be larger than the number of series elements this Resource contains due to resource availability, security, or other factors. This element should be present if any series elements are present. | |
![]() ![]() ![]() |
0..1 | integer | Number of Service-Object Pairs (SOP) Instances in Study. This value given may be larger than the number of instance elements this resource contains due to resource availability, security, or other factors. This element should be present if any instance elements are present. | |
![]() ![]() ![]() |
0..1 | string | The Imaging Manager description of the study. Institution-generated description or classification of the Study (component) performed. | |
![]() ![]() ![]() |
0..1 | EHDSOrganisation | Organisation name, address, contact information. | |
![]() ![]() ![]() |
0..1 | EHDSEndpoint | Study endpoint describing the technical details of a location that can be connected to for the delivery/retrieval of information. Sufficient information is required to ensure that a connection can be made securely, and appropriate data transmitted as defined by the endpoint owner. These may be locally hosted services, regional services, or national service. | |
![]() ![]() ![]() |
0..* | Base | Series. Each study has one or more series of instances, but they may be absent when no series information needs to be conveyed | |
![]() ![]() ![]() ![]() |
1..1 | Identifier | DICOM Series Instance UID for the series | |
![]() ![]() ![]() ![]() |
0..1 | integer | Numeric identifier of this series | |
![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Acquisition modality - the modality used for this series Binding Description: (preferred): DICOM CID029 | |
![]() ![]() ![]() ![]() |
0..1 | string | A short human readable summary of the series | |
![]() ![]() ![]() ![]() |
0..1 | integer | Number of Series Related Instances | |
![]() ![]() ![]() ![]() |
0..1 | EHDSEndpoint | Series endpoint describing the technical details of a location that can be connected to for the delivery/retrieval of information. Sufficient information is required to ensure that a connection can be made securely, and appropriate data transmitted as defined by the endpoint owner. These may be locally hosted services, regional services, or national service. | |
![]() ![]() ![]() ![]() |
0..1 | EHDSBodyStructure | Body part (with laterality) examined | |
![]() ![]() ![]() ![]() |
0..* | EHDSSpecimen | Specimen imaged | |
![]() ![]() ![]() ![]() |
0..1 | dateTime | When the series started | |
![]() ![]() ![]() ![]() |
0..* | Base | Each series has one or more instances, but they may be absent when no instance information needs to be conveyed | |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Instance title that is the description of the instance. | |
![]() ![]() ![]() ![]() ![]() |
1..1 | Identifier | DICOM SOP Instance UID | |
![]() ![]() ![]() ![]() ![]() |
1..1 | uri | SOP class - DICOM class type | |
![]() ![]() ![]() ![]() ![]() |
0..1 | integer | The number of this instance in the series | |
![]() ![]() ![]() ![]() ![]() |
0..1 | integer | The number of frames in a multiframe instance | |
![]() |
Path | Conformance | ValueSet | URI |
EHDSImagingStudy.header.language | preferred | ||
EHDSImagingStudy.modality | preferred | ||
EHDSImagingStudy.series.acquisitionModality | preferred |
This structure is derived from EHDSDataSet
Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
---|---|---|---|---|
![]() ![]() |
0..* | EHDSDataSet | Elements defined in Ancestors:header Imaging study model Instances of this logical model can be the target of a Reference | |
![]() ![]() ![]() |
||||
![]() ![]() ![]() ![]() |
1..* | Identifier | Identifiers for the Imaging Study such as DICOM Study Instance UID. If one or more series elements are present in the ImagingStudy, then there shall be one DICOM Study UID identifier. | |
![]() ![]() ![]() |
0..* | CodeableConcept | All of the distinct values for series' modalities Binding Description: (preferred): DICOM CID029 | |
![]() ![]() ![]() |
0..1 | EHDSEncounter | Reference to the encounter with which this imaging study is associated | |
![]() ![]() ![]() |
0..1 | dateTime | Date and time the study started. | |
![]() ![]() ![]() |
0..* | EHDSServiceRequest | References to the diagnostic requests that resulted in this imaging study being performed. | |
![]() ![]() ![]() |
0..1 | integer | Number of Series in the Study. This value given may be larger than the number of series elements this Resource contains due to resource availability, security, or other factors. This element should be present if any series elements are present. | |
![]() ![]() ![]() |
0..1 | integer | Number of Service-Object Pairs (SOP) Instances in Study. This value given may be larger than the number of instance elements this resource contains due to resource availability, security, or other factors. This element should be present if any instance elements are present. | |
![]() ![]() ![]() |
0..1 | string | The Imaging Manager description of the study. Institution-generated description or classification of the Study (component) performed. | |
![]() ![]() ![]() |
0..1 | EHDSOrganisation | Organisation name, address, contact information. | |
![]() ![]() ![]() |
0..1 | EHDSEndpoint | Study endpoint describing the technical details of a location that can be connected to for the delivery/retrieval of information. Sufficient information is required to ensure that a connection can be made securely, and appropriate data transmitted as defined by the endpoint owner. These may be locally hosted services, regional services, or national service. | |
![]() ![]() ![]() |
0..* | Base | Series. Each study has one or more series of instances, but they may be absent when no series information needs to be conveyed | |
![]() ![]() ![]() ![]() |
1..1 | Identifier | DICOM Series Instance UID for the series | |
![]() ![]() ![]() ![]() |
0..1 | integer | Numeric identifier of this series | |
![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Acquisition modality - the modality used for this series Binding Description: (preferred): DICOM CID029 | |
![]() ![]() ![]() ![]() |
0..1 | string | A short human readable summary of the series | |
![]() ![]() ![]() ![]() |
0..1 | integer | Number of Series Related Instances | |
![]() ![]() ![]() ![]() |
0..1 | EHDSEndpoint | Series endpoint describing the technical details of a location that can be connected to for the delivery/retrieval of information. Sufficient information is required to ensure that a connection can be made securely, and appropriate data transmitted as defined by the endpoint owner. These may be locally hosted services, regional services, or national service. | |
![]() ![]() ![]() ![]() |
0..1 | EHDSBodyStructure | Body part (with laterality) examined | |
![]() ![]() ![]() ![]() |
0..* | EHDSSpecimen | Specimen imaged | |
![]() ![]() ![]() ![]() |
0..1 | dateTime | When the series started | |
![]() ![]() ![]() ![]() |
0..* | Base | Each series has one or more instances, but they may be absent when no instance information needs to be conveyed | |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Instance title that is the description of the instance. | |
![]() ![]() ![]() ![]() ![]() |
1..1 | Identifier | DICOM SOP Instance UID | |
![]() ![]() ![]() ![]() ![]() |
1..1 | uri | SOP class - DICOM class type | |
![]() ![]() ![]() ![]() ![]() |
0..1 | integer | The number of this instance in the series | |
![]() ![]() ![]() ![]() ![]() |
0..1 | integer | The number of frames in a multiframe instance | |
![]() |
Path | Conformance | ValueSet | URI |
EHDSImagingStudy.modality | preferred | ||
EHDSImagingStudy.series.acquisitionModality | preferred |
Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
---|---|---|---|---|
![]() ![]() |
0..* | EHDSDataSet | Elements defined in Ancestors:header Imaging study model Instances of this logical model can be the target of a Reference | |
![]() ![]() ![]() |
1..1 | Base | Common header for all patient-related data | |
![]() ![]() ![]() ![]() |
1..1 | EHDSPatient | Patient/subject information | |
![]() ![]() ![]() ![]() |
1..* | Identifier | Identifiers for the Imaging Study such as DICOM Study Instance UID. If one or more series elements are present in the ImagingStudy, then there shall be one DICOM Study UID identifier. | |
![]() ![]() ![]() ![]() |
1..* | Base | Resource authoring details | |
![]() ![]() ![]() ![]() ![]() |
1..1 | Author(s) by whom the resource was/were authored. Multiple authors could be provided. | ||
![]() ![]() ![]() ![]() ![]() ![]() |
EHDSHealthProfessional | |||
![]() ![]() ![]() ![]() ![]() ![]() |
EHDSOrganisation | |||
![]() ![]() ![]() ![]() ![]() ![]() |
EHDSDevice | |||
![]() ![]() ![]() ![]() ![]() |
1..1 | dateTime | Date and time of authoring/issuing | |
![]() ![]() ![]() ![]() |
0..1 | dateTime | Date and time of the last update to the resource (may be used for technical corrections). | |
![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Status of the resource or document | |
![]() ![]() ![]() ![]() |
0..1 | Reason for the current status of the resource. | ||
![]() ![]() ![]() ![]() ![]() |
CodeableConcept | |||
![]() ![]() ![]() ![]() ![]() |
string | |||
![]() ![]() ![]() ![]() |
0..1 | CodeableConcept | Language in which the resource is written. Language is expressed by the IETF language tag. Binding Description: (preferred): BCP 47 | |
![]() ![]() ![]() |
0..* | CodeableConcept | All of the distinct values for series' modalities Binding Description: (preferred): DICOM CID029 | |
![]() ![]() ![]() |
0..1 | EHDSEncounter | Reference to the encounter with which this imaging study is associated | |
![]() ![]() ![]() |
0..1 | dateTime | Date and time the study started. | |
![]() ![]() ![]() |
0..* | EHDSServiceRequest | References to the diagnostic requests that resulted in this imaging study being performed. | |
![]() ![]() ![]() |
0..1 | integer | Number of Series in the Study. This value given may be larger than the number of series elements this Resource contains due to resource availability, security, or other factors. This element should be present if any series elements are present. | |
![]() ![]() ![]() |
0..1 | integer | Number of Service-Object Pairs (SOP) Instances in Study. This value given may be larger than the number of instance elements this resource contains due to resource availability, security, or other factors. This element should be present if any instance elements are present. | |
![]() ![]() ![]() |
0..1 | string | The Imaging Manager description of the study. Institution-generated description or classification of the Study (component) performed. | |
![]() ![]() ![]() |
0..1 | EHDSOrganisation | Organisation name, address, contact information. | |
![]() ![]() ![]() |
0..1 | EHDSEndpoint | Study endpoint describing the technical details of a location that can be connected to for the delivery/retrieval of information. Sufficient information is required to ensure that a connection can be made securely, and appropriate data transmitted as defined by the endpoint owner. These may be locally hosted services, regional services, or national service. | |
![]() ![]() ![]() |
0..* | Base | Series. Each study has one or more series of instances, but they may be absent when no series information needs to be conveyed | |
![]() ![]() ![]() ![]() |
1..1 | Identifier | DICOM Series Instance UID for the series | |
![]() ![]() ![]() ![]() |
0..1 | integer | Numeric identifier of this series | |
![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Acquisition modality - the modality used for this series Binding Description: (preferred): DICOM CID029 | |
![]() ![]() ![]() ![]() |
0..1 | string | A short human readable summary of the series | |
![]() ![]() ![]() ![]() |
0..1 | integer | Number of Series Related Instances | |
![]() ![]() ![]() ![]() |
0..1 | EHDSEndpoint | Series endpoint describing the technical details of a location that can be connected to for the delivery/retrieval of information. Sufficient information is required to ensure that a connection can be made securely, and appropriate data transmitted as defined by the endpoint owner. These may be locally hosted services, regional services, or national service. | |
![]() ![]() ![]() ![]() |
0..1 | EHDSBodyStructure | Body part (with laterality) examined | |
![]() ![]() ![]() ![]() |
0..* | EHDSSpecimen | Specimen imaged | |
![]() ![]() ![]() ![]() |
0..1 | dateTime | When the series started | |
![]() ![]() ![]() ![]() |
0..* | Base | Each series has one or more instances, but they may be absent when no instance information needs to be conveyed | |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Instance title that is the description of the instance. | |
![]() ![]() ![]() ![]() ![]() |
1..1 | Identifier | DICOM SOP Instance UID | |
![]() ![]() ![]() ![]() ![]() |
1..1 | uri | SOP class - DICOM class type | |
![]() ![]() ![]() ![]() ![]() |
0..1 | integer | The number of this instance in the series | |
![]() ![]() ![]() ![]() ![]() |
0..1 | integer | The number of frames in a multiframe instance | |
![]() |
Path | Conformance | ValueSet | URI |
EHDSImagingStudy.header.language | preferred | ||
EHDSImagingStudy.modality | preferred | ||
EHDSImagingStudy.series.acquisitionModality | preferred |
This structure is derived from EHDSDataSet
Key Elements View
Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
---|---|---|---|---|
![]() ![]() |
0..* | EHDSDataSet | Elements defined in Ancestors:header Imaging study model Instances of this logical model can be the target of a Reference | |
![]() ![]() ![]() |
1..1 | Base | Common header for all patient-related data | |
![]() ![]() ![]() ![]() |
1..1 | EHDSPatient | Patient/subject information | |
![]() ![]() ![]() ![]() |
1..* | Identifier | Identifiers for the Imaging Study such as DICOM Study Instance UID. If one or more series elements are present in the ImagingStudy, then there shall be one DICOM Study UID identifier. | |
![]() ![]() ![]() ![]() |
1..* | Base | Resource authoring details | |
![]() ![]() ![]() ![]() ![]() |
1..1 | Author(s) by whom the resource was/were authored. Multiple authors could be provided. | ||
![]() ![]() ![]() ![]() ![]() ![]() |
EHDSHealthProfessional | |||
![]() ![]() ![]() ![]() ![]() ![]() |
EHDSOrganisation | |||
![]() ![]() ![]() ![]() ![]() ![]() |
EHDSDevice | |||
![]() ![]() ![]() ![]() ![]() |
1..1 | dateTime | Date and time of authoring/issuing | |
![]() ![]() ![]() ![]() |
0..1 | dateTime | Date and time of the last update to the resource (may be used for technical corrections). | |
![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Status of the resource or document | |
![]() ![]() ![]() ![]() |
0..1 | Reason for the current status of the resource. | ||
![]() ![]() ![]() ![]() ![]() |
CodeableConcept | |||
![]() ![]() ![]() ![]() ![]() |
string | |||
![]() ![]() ![]() ![]() |
0..1 | CodeableConcept | Language in which the resource is written. Language is expressed by the IETF language tag. Binding Description: (preferred): BCP 47 | |
![]() ![]() ![]() |
0..* | CodeableConcept | All of the distinct values for series' modalities Binding Description: (preferred): DICOM CID029 | |
![]() ![]() ![]() |
0..1 | EHDSEncounter | Reference to the encounter with which this imaging study is associated | |
![]() ![]() ![]() |
0..1 | dateTime | Date and time the study started. | |
![]() ![]() ![]() |
0..* | EHDSServiceRequest | References to the diagnostic requests that resulted in this imaging study being performed. | |
![]() ![]() ![]() |
0..1 | integer | Number of Series in the Study. This value given may be larger than the number of series elements this Resource contains due to resource availability, security, or other factors. This element should be present if any series elements are present. | |
![]() ![]() ![]() |
0..1 | integer | Number of Service-Object Pairs (SOP) Instances in Study. This value given may be larger than the number of instance elements this resource contains due to resource availability, security, or other factors. This element should be present if any instance elements are present. | |
![]() ![]() ![]() |
0..1 | string | The Imaging Manager description of the study. Institution-generated description or classification of the Study (component) performed. | |
![]() ![]() ![]() |
0..1 | EHDSOrganisation | Organisation name, address, contact information. | |
![]() ![]() ![]() |
0..1 | EHDSEndpoint | Study endpoint describing the technical details of a location that can be connected to for the delivery/retrieval of information. Sufficient information is required to ensure that a connection can be made securely, and appropriate data transmitted as defined by the endpoint owner. These may be locally hosted services, regional services, or national service. | |
![]() ![]() ![]() |
0..* | Base | Series. Each study has one or more series of instances, but they may be absent when no series information needs to be conveyed | |
![]() ![]() ![]() ![]() |
1..1 | Identifier | DICOM Series Instance UID for the series | |
![]() ![]() ![]() ![]() |
0..1 | integer | Numeric identifier of this series | |
![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Acquisition modality - the modality used for this series Binding Description: (preferred): DICOM CID029 | |
![]() ![]() ![]() ![]() |
0..1 | string | A short human readable summary of the series | |
![]() ![]() ![]() ![]() |
0..1 | integer | Number of Series Related Instances | |
![]() ![]() ![]() ![]() |
0..1 | EHDSEndpoint | Series endpoint describing the technical details of a location that can be connected to for the delivery/retrieval of information. Sufficient information is required to ensure that a connection can be made securely, and appropriate data transmitted as defined by the endpoint owner. These may be locally hosted services, regional services, or national service. | |
![]() ![]() ![]() ![]() |
0..1 | EHDSBodyStructure | Body part (with laterality) examined | |
![]() ![]() ![]() ![]() |
0..* | EHDSSpecimen | Specimen imaged | |
![]() ![]() ![]() ![]() |
0..1 | dateTime | When the series started | |
![]() ![]() ![]() ![]() |
0..* | Base | Each series has one or more instances, but they may be absent when no instance information needs to be conveyed | |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Instance title that is the description of the instance. | |
![]() ![]() ![]() ![]() ![]() |
1..1 | Identifier | DICOM SOP Instance UID | |
![]() ![]() ![]() ![]() ![]() |
1..1 | uri | SOP class - DICOM class type | |
![]() ![]() ![]() ![]() ![]() |
0..1 | integer | The number of this instance in the series | |
![]() ![]() ![]() ![]() ![]() |
0..1 | integer | The number of frames in a multiframe instance | |
![]() |
Path | Conformance | ValueSet | URI |
EHDSImagingStudy.header.language | preferred | ||
EHDSImagingStudy.modality | preferred | ||
EHDSImagingStudy.series.acquisitionModality | preferred |
Differential View
This structure is derived from EHDSDataSet
Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
---|---|---|---|---|
![]() ![]() |
0..* | EHDSDataSet | Elements defined in Ancestors:header Imaging study model Instances of this logical model can be the target of a Reference | |
![]() ![]() ![]() |
||||
![]() ![]() ![]() ![]() |
1..* | Identifier | Identifiers for the Imaging Study such as DICOM Study Instance UID. If one or more series elements are present in the ImagingStudy, then there shall be one DICOM Study UID identifier. | |
![]() ![]() ![]() |
0..* | CodeableConcept | All of the distinct values for series' modalities Binding Description: (preferred): DICOM CID029 | |
![]() ![]() ![]() |
0..1 | EHDSEncounter | Reference to the encounter with which this imaging study is associated | |
![]() ![]() ![]() |
0..1 | dateTime | Date and time the study started. | |
![]() ![]() ![]() |
0..* | EHDSServiceRequest | References to the diagnostic requests that resulted in this imaging study being performed. | |
![]() ![]() ![]() |
0..1 | integer | Number of Series in the Study. This value given may be larger than the number of series elements this Resource contains due to resource availability, security, or other factors. This element should be present if any series elements are present. | |
![]() ![]() ![]() |
0..1 | integer | Number of Service-Object Pairs (SOP) Instances in Study. This value given may be larger than the number of instance elements this resource contains due to resource availability, security, or other factors. This element should be present if any instance elements are present. | |
![]() ![]() ![]() |
0..1 | string | The Imaging Manager description of the study. Institution-generated description or classification of the Study (component) performed. | |
![]() ![]() ![]() |
0..1 | EHDSOrganisation | Organisation name, address, contact information. | |
![]() ![]() ![]() |
0..1 | EHDSEndpoint | Study endpoint describing the technical details of a location that can be connected to for the delivery/retrieval of information. Sufficient information is required to ensure that a connection can be made securely, and appropriate data transmitted as defined by the endpoint owner. These may be locally hosted services, regional services, or national service. | |
![]() ![]() ![]() |
0..* | Base | Series. Each study has one or more series of instances, but they may be absent when no series information needs to be conveyed | |
![]() ![]() ![]() ![]() |
1..1 | Identifier | DICOM Series Instance UID for the series | |
![]() ![]() ![]() ![]() |
0..1 | integer | Numeric identifier of this series | |
![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Acquisition modality - the modality used for this series Binding Description: (preferred): DICOM CID029 | |
![]() ![]() ![]() ![]() |
0..1 | string | A short human readable summary of the series | |
![]() ![]() ![]() ![]() |
0..1 | integer | Number of Series Related Instances | |
![]() ![]() ![]() ![]() |
0..1 | EHDSEndpoint | Series endpoint describing the technical details of a location that can be connected to for the delivery/retrieval of information. Sufficient information is required to ensure that a connection can be made securely, and appropriate data transmitted as defined by the endpoint owner. These may be locally hosted services, regional services, or national service. | |
![]() ![]() ![]() ![]() |
0..1 | EHDSBodyStructure | Body part (with laterality) examined | |
![]() ![]() ![]() ![]() |
0..* | EHDSSpecimen | Specimen imaged | |
![]() ![]() ![]() ![]() |
0..1 | dateTime | When the series started | |
![]() ![]() ![]() ![]() |
0..* | Base | Each series has one or more instances, but they may be absent when no instance information needs to be conveyed | |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Instance title that is the description of the instance. | |
![]() ![]() ![]() ![]() ![]() |
1..1 | Identifier | DICOM SOP Instance UID | |
![]() ![]() ![]() ![]() ![]() |
1..1 | uri | SOP class - DICOM class type | |
![]() ![]() ![]() ![]() ![]() |
0..1 | integer | The number of this instance in the series | |
![]() ![]() ![]() ![]() ![]() |
0..1 | integer | The number of frames in a multiframe instance | |
![]() |
Path | Conformance | ValueSet | URI |
EHDSImagingStudy.modality | preferred | ||
EHDSImagingStudy.series.acquisitionModality | preferred |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
---|---|---|---|---|
![]() ![]() |
0..* | EHDSDataSet | Elements defined in Ancestors:header Imaging study model Instances of this logical model can be the target of a Reference | |
![]() ![]() ![]() |
1..1 | Base | Common header for all patient-related data | |
![]() ![]() ![]() ![]() |
1..1 | EHDSPatient | Patient/subject information | |
![]() ![]() ![]() ![]() |
1..* | Identifier | Identifiers for the Imaging Study such as DICOM Study Instance UID. If one or more series elements are present in the ImagingStudy, then there shall be one DICOM Study UID identifier. | |
![]() ![]() ![]() ![]() |
1..* | Base | Resource authoring details | |
![]() ![]() ![]() ![]() ![]() |
1..1 | Author(s) by whom the resource was/were authored. Multiple authors could be provided. | ||
![]() ![]() ![]() ![]() ![]() ![]() |
EHDSHealthProfessional | |||
![]() ![]() ![]() ![]() ![]() ![]() |
EHDSOrganisation | |||
![]() ![]() ![]() ![]() ![]() ![]() |
EHDSDevice | |||
![]() ![]() ![]() ![]() ![]() |
1..1 | dateTime | Date and time of authoring/issuing | |
![]() ![]() ![]() ![]() |
0..1 | dateTime | Date and time of the last update to the resource (may be used for technical corrections). | |
![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Status of the resource or document | |
![]() ![]() ![]() ![]() |
0..1 | Reason for the current status of the resource. | ||
![]() ![]() ![]() ![]() ![]() |
CodeableConcept | |||
![]() ![]() ![]() ![]() ![]() |
string | |||
![]() ![]() ![]() ![]() |
0..1 | CodeableConcept | Language in which the resource is written. Language is expressed by the IETF language tag. Binding Description: (preferred): BCP 47 | |
![]() ![]() ![]() |
0..* | CodeableConcept | All of the distinct values for series' modalities Binding Description: (preferred): DICOM CID029 | |
![]() ![]() ![]() |
0..1 | EHDSEncounter | Reference to the encounter with which this imaging study is associated | |
![]() ![]() ![]() |
0..1 | dateTime | Date and time the study started. | |
![]() ![]() ![]() |
0..* | EHDSServiceRequest | References to the diagnostic requests that resulted in this imaging study being performed. | |
![]() ![]() ![]() |
0..1 | integer | Number of Series in the Study. This value given may be larger than the number of series elements this Resource contains due to resource availability, security, or other factors. This element should be present if any series elements are present. | |
![]() ![]() ![]() |
0..1 | integer | Number of Service-Object Pairs (SOP) Instances in Study. This value given may be larger than the number of instance elements this resource contains due to resource availability, security, or other factors. This element should be present if any instance elements are present. | |
![]() ![]() ![]() |
0..1 | string | The Imaging Manager description of the study. Institution-generated description or classification of the Study (component) performed. | |
![]() ![]() ![]() |
0..1 | EHDSOrganisation | Organisation name, address, contact information. | |
![]() ![]() ![]() |
0..1 | EHDSEndpoint | Study endpoint describing the technical details of a location that can be connected to for the delivery/retrieval of information. Sufficient information is required to ensure that a connection can be made securely, and appropriate data transmitted as defined by the endpoint owner. These may be locally hosted services, regional services, or national service. | |
![]() ![]() ![]() |
0..* | Base | Series. Each study has one or more series of instances, but they may be absent when no series information needs to be conveyed | |
![]() ![]() ![]() ![]() |
1..1 | Identifier | DICOM Series Instance UID for the series | |
![]() ![]() ![]() ![]() |
0..1 | integer | Numeric identifier of this series | |
![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Acquisition modality - the modality used for this series Binding Description: (preferred): DICOM CID029 | |
![]() ![]() ![]() ![]() |
0..1 | string | A short human readable summary of the series | |
![]() ![]() ![]() ![]() |
0..1 | integer | Number of Series Related Instances | |
![]() ![]() ![]() ![]() |
0..1 | EHDSEndpoint | Series endpoint describing the technical details of a location that can be connected to for the delivery/retrieval of information. Sufficient information is required to ensure that a connection can be made securely, and appropriate data transmitted as defined by the endpoint owner. These may be locally hosted services, regional services, or national service. | |
![]() ![]() ![]() ![]() |
0..1 | EHDSBodyStructure | Body part (with laterality) examined | |
![]() ![]() ![]() ![]() |
0..* | EHDSSpecimen | Specimen imaged | |
![]() ![]() ![]() ![]() |
0..1 | dateTime | When the series started | |
![]() ![]() ![]() ![]() |
0..* | Base | Each series has one or more instances, but they may be absent when no instance information needs to be conveyed | |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Instance title that is the description of the instance. | |
![]() ![]() ![]() ![]() ![]() |
1..1 | Identifier | DICOM SOP Instance UID | |
![]() ![]() ![]() ![]() ![]() |
1..1 | uri | SOP class - DICOM class type | |
![]() ![]() ![]() ![]() ![]() |
0..1 | integer | The number of this instance in the series | |
![]() ![]() ![]() ![]() ![]() |
0..1 | integer | The number of frames in a multiframe instance | |
![]() |
Path | Conformance | ValueSet | URI |
EHDSImagingStudy.header.language | preferred | ||
EHDSImagingStudy.modality | preferred | ||
EHDSImagingStudy.series.acquisitionModality | preferred |
This structure is derived from EHDSDataSet