Specyfikacja interoperacyjności prototypu SSIDL
0.1.1 - ci-build
Specyfikacja interoperacyjności prototypu SSIDL, published by Uniwersytet Medyczny w Łodzi. This guide is not an authorized publication; it is the continuous build for version 0.1.1 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/SSIDL/ssidl-ig/ and changes regularly. See the Directory of published versions
<Bundle xmlns="http://hl7.org/fhir">
<id value="SsidlLabProcedureDefinition-777-3"/>
<type value="transaction"/>
<entry>
<fullUrl value="SsidlLabServiceDefinition-777-3"/>
<resource>
<ActivityDefinition>
<id value="SsidlLabServiceDefinition-777-3"/>
<meta>
<profile
value="http://loinc-ssidl.umed.pl/fhir/ig/ssidl/StructureDefinition/ssidl-activityDefinition-labServiceDefinition"/>
</meta>
<text>
<status value="generated"/>
<div><a name="ActivityDefinition_SsidlLabServiceDefinition-777-3"> </a><p><strong>Definicja usługi laboratoryjnej</strong></p><p><strong>Płytki krwi</strong></p><ul><li>LOINC: <strong><strong><strong>[</strong></strong></strong><strong><strong><strong>777-3</strong>] </strong></strong><strong>Płytki krwi: stężenie liczbowe: punkt w czasie: krew: ilościowy: automatyczne liczenie</strong></li><li>ICD-9-PL: <strong>[C66] Płytki krwi - liczba</strong></li></ul><p><a href="SpecimenDefinition-SsidlSpecimenDefinition-777-3">Czynniki przedanalityczne</a></p><p>Wymagany test laboratoryjny:</p><ul><li><a href="ObservationDefinition-SsidlLabTestDefinition-777-3.html">[777-3] Płytki krwi</a></li></ul></div>
</text>
<url
value="http://loinc-ssidl.umed.pl/fhir/ig/ssidl/ActivityDefinition/ssidl-labServiceDefinition-777-3"/>
<version value="1"/>
<title value="Płytki krwi"/>
<status value="active"/>
<useContext>
<code>
<system
value="http://terminology.hl7.org/CodeSystem/usage-context-type"/>
<code value="workflow"/>
<display value="Workflow Setting"/>
</code>
<valueCodeableConcept>
<coding>
<system
value="http://loinc-ssidl.umed.pl/fhir/ig/ssidl/CodeSystem/ssidl-definitionUseContext-CS"/>
<code value="BW"/>
<display value="Baza wiedzy SSIDL"/>
</coding>
</valueCodeableConcept>
</useContext>
<kind value="Task"/>
<code>
<coding>
<system value="http://loinc.com"/>
<code value="777-3"/>
<display
value="Płytki krwi: stężenie liczbowe: punkt w czasie: krew: ilościowy: automatyczne liczenie"/>
</coding>
<coding>
<system value="urn:oid:2.16.840.1.113883.3.4424.11.2.6"/>
<code value="C66"/>
<display value="Płytki krwi – liczba"/>
</coding>
</code>
<specimenRequirement
value="http://loinc-ssidl.umed.pl/fhir/ig/ssidl/SpecimenDefinition/ssidl-specimenDefinition-777-3"/>
<observationResultRequirement
value="http://loinc-ssidl.umed.pl/fhir/ig/ssidl/ObservationDefinition/ssidl-labTestDefinition-777-3"/>
</ActivityDefinition>
</resource>
<request>
<method value="POST"/>
<url value="ActivityDefinition"/>
</request>
</entry>
<entry>
<fullUrl value="SsidlSpecimenDefinition-777-3"/>
<resource>
<SpecimenDefinition>
<id value="SsidlSpecimenDefinition-777-3"/>
<meta>
<profile
value="http://loinc-ssidl.umed.pl/fhir/ig/ssidl/StructureDefinition/ssidl-specimenDefinition-alt"/>
</meta>
<text>
<status value="generated"/>
<div><a name="SpecimenDefinition_SsidlSpecimenDefinition-777-3"> </a><p><strong>Czynniki przedanalityczne</strong></p><ul><li>Materiał pobierany: <strong>[LP7057-5] krew</strong></li><li>Przygotowanie pacjenta:<strong><strong><strong> Pobranie w godzinach porannych</strong></strong></strong></li><li>Przechowywanie i transport próbki:<strong><strong><strong> </strong></strong>Transport w temperaturze pokojowej (15-25 st. C max. 2h)</strong></li></ul></div>
</text>
<url
value="http://loinc-ssidl.umed.pl/fhir/ig/ssidl/SpecimenDefinition/ssidl-specimenDefinition-777-3"/>
<status value="active"/>
<typeCollected>
<coding>
<system value="http://loinc.org/part"/>
<code value="LP7057-5"/>
<display value="krew"/>
</coding>
</typeCollected>
<patientPreparation>
<text value="Pobranie w godzinach porannych"/>
</patientPreparation>
<typeTested>
<preference value="preferred"/>
<handling>
<temperatureQualifier>
<text value="Transport w temperaturze pokojowej"/>
</temperatureQualifier>
<temperatureRange>
<low>
<value value="15"/>
<unit value="Cel"/>
</low>
<high>
<value value="25"/>
<unit value="Cel"/>
</high>
</temperatureRange>
<maxDuration>
<value value="2"/>
<unit value="godzina(godzin)"/>
<system value="http://unitsofmeasure.org"/>
<code value="h"/>
</maxDuration>
</handling>
</typeTested>
</SpecimenDefinition>
</resource>
<request>
<method value="POST"/>
<url value="SpecimenDefinition"/>
</request>
</entry>
<entry>
<fullUrl value="SsidlLabTestDefinition-777-3"/>
<resource>
<ObservationDefinition>
<id value="SsidlLabTestDefinition-777-3"/>
<meta>
<profile
value="http://loinc-ssidl.umed.pl/fhir/ig/ssidl/StructureDefinition/ssidl-observationDefinition-labTestDefinition"/>
</meta>
<text>
<status value="extensions"/>
<div><a name="ObservationDefinition_SsidlLabTestDefinition-777-3"> </a><p><strong>Definicja testu laboratoryjnego</strong></p><div><p>Sugerowana nazwa na wyniku badania: <strong>Płytki krwi</strong></p><p>LOINC: <strong>[777-3] Płytki krwi: stężenie liczbowe: punkt w czasie: krew: ilościowy: automatyczne liczenie</strong></p></div><p>Metoda: [LP6141-8] Automatyczne zliczanie</p><p>Jednostka wyniku: <strong>/uL 'na mikrolitr'</strong></p><p><strong>Wartości referencyjne</strong><a href="Citation-SsidlCitation-1.html"> (źródło)</a></p><ul><li><strong>Wartości normalne: 150-400 <strong>/uL</strong></strong></li></ul></div>
</text>
<url
value="http://loinc-ssidl.umed.pl/fhir/ig/ssidl/ObservationDefinition/ssidl-labTestDefinition-777-3"/>
<version value="1"/>
<title
value="Płytki krwi: stężenie liczbowe: punkt w czasie: krew: ilościowy: automatyczne liczenie"/>
<status value="active"/>
<useContext>
<code>
<system
value="http://terminology.hl7.org/CodeSystem/usage-context-type"/>
<code value="workflow"/>
<display value="Workflow Setting"/>
</code>
<valueCodeableConcept>
<coding>
<system
value="http://loinc-ssidl.umed.pl/fhir/ig/ssidl/CodeSystem/ssidl-definitionUseContext-CS"/>
<code value="BW"/>
<display value="Baza wiedzy SSIDL"/>
</coding>
</valueCodeableConcept>
</useContext>
<code>
<coding>
<system value="http://loinc.com"/>
<code value="777-3"/>
<display
value="Płytki krwi: stężenie liczbowe: punkt w czasie: krew: ilościowy: automatyczne liczenie"/>
</coding>
</code>
<permittedDataType value="Quantity"/>
<method>
<coding>
<system value="http://loinc.org/part"/>
<code value="LP6141-8"/>
<display value="Automatyczne zliczanie"/>
</coding>
</method>
<preferredReportName value="Płytki krwi"/>
<permittedUnit>
<system value="http://unitsofmeasure.org"/>
<code value="/uL"/>
<display value="na mikrolitr"/>
</permittedUnit>
<qualifiedValue>
<extension
url="http://loinc-ssidl.umed.pl/fhir/ig/ssidl/StructureDefinition/observationDefinition-qualifiedValue-sourceInfoReference">
<valueReference>🔗
<reference value="Citation/SsidlCitation-1"/>
</valueReference>
</extension>
<context>
<coding>
<system
value="http://terminology.hl7.org/5.1.0/CodeSystem-referencerange-meaning.html"/>
<code value="normal"/>
<display value="Wartości normalne"/>
</coding>
</context>
<range>
<low>
<value value="150"/>
<unit value="/uL"/>
</low>
<high>
<value value="400"/>
<unit value="/uL"/>
</high>
</range>
</qualifiedValue>
</ObservationDefinition>
</resource>
<request>
<method value="POST"/>
<url value="ObservationDefinition"/>
</request>
</entry>
</Bundle>